Accuracy of iodine removal using dual-energy CT with or without a tin filter: an experimental phantom study

被引:6
作者
Kawai, Tatsuya [1 ]
Takeuchi, Mitsuru [1 ]
Hara, Masaki [1 ]
Ohashi, Kazuya [2 ]
Suzuki, Hirochika [3 ]
Yamada, Kiyotaka [3 ]
Sugimura, Yuya [3 ]
Shibamoto, Yuta [1 ]
机构
[1] Nagoya City Univ, Grad Sch Med Sci, Dept Radiol, Nagoya, Aichi, Japan
[2] Nagoya City Univ Hosp, Div Cent Radiol, Nagoya, Aichi, Japan
[3] Tsushima City Hosp, Div Radiol, Tsushima City, Japan
关键词
Dual-energy; CT; contrast agents; tin filter; technology assessments; LUNG PERFUSION; DIFFERENTIATION; FEASIBILITY; TOMOGRAPHY; STONES;
D O I
10.1177/0284185113485068
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The effects of a tin filter on virtual non-enhanced (VNE) images created by dual-energy CT have not been well evaluated. Purpose: To compare the accuracy of VNE images between those with and without a tin filter. Material and Methods: Two different types of columnar phantoms made of agarose gel were evaluated. Phantom A contained various concentrations of iodine (4.5-1590 HU at 120 kVp). Phantom B consisted of a central component (0, 10, 25, and 40 mgl/cm(3)) and a surrounding component (0, 50, 100, and 200 mgl/cm(3)) with variable iodine concentration. They were scanned by dual-source CT in conventional single-energy mode and dual-energy mode with and without a tin filter. CT values on each gel at the corresponding points were measured and the accuracy of iodine removal was evaluated. Results: On VNE images, the CT number of the gel of Phantom A fell within the range between -15 and +15 HU under 626 and 881 HU at single-energy 120 kVp with and without a tin filter, respectively. With attenuation over these thresholds, iodine concentration of gels was underestimated with the tin filter but overestimated without it. For Phantom B, the mean CT numbers on VNE images in the central gel component surrounded by the gel with iodine concentrations of 0, 50, 100, and 200 mgl/cm(3) were in the range of -19-+6 HU and 21-100 HU with and without the tin filter, respectively. Conclusion: Both with and without a tin filter, iodine removal was accurate under a threshold of iodine concentration. Although a surrounding structure with higher attenuation decreased the accuracy, a tin filter improved the margin of error.
引用
收藏
页码:954 / 960
页数:7
相关论文
共 16 条
[1]   BEAM HARDENING IN X-RAY RECONSTRUCTIVE TOMOGRAPHY [J].
BROOKS, RA ;
DICHIRO, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (03) :390-398
[2]   Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[3]   Can Dual-energy CT Evaluate Contrast Enhancement of Ground-glass Attenuation? Phantom and Preliminary Clinical Studies [J].
Kawai, Tatsuya ;
Shibamoto, Yuta ;
Hara, Masaki ;
Arakawa, Toshinao ;
Nagai, Keiichi ;
Ohashi, Kazuya .
ACADEMIC RADIOLOGY, 2011, 18 (06) :682-689
[4]   Image-based dual energy CT using optimized precorrection functions: A practical new approach of material decomposition in image domain [J].
Maass, Clemens ;
Baer, Matthias ;
Kachelriess, Marc .
MEDICAL PHYSICS, 2009, 36 (08) :3818-3829
[5]   Renal cyst pseudoenhancement: Beam-hardening effects on CT numbers [J].
Maki, DD ;
Birnbaum, BA ;
Chakraborty, DP ;
Jacobs, JE ;
Carvalho, BM ;
Herman, GT .
RADIOLOGY, 1999, 213 (02) :468-472
[6]   Dual Source Computed Tomography: A Novel Technique to Determine Stone Composition [J].
Matlaga, Brian R. ;
Kawamoto, Satomi ;
Fishman, Elliot .
UROLOGY, 2008, 72 (05) :1164-1168
[7]   Lung Perfusion with Dual-Energy Multi-detector Row CT Can It Help Recognize Ground Glass Opacities of Vascular Origin? [J].
Pontana, Francois ;
Remy-Jardin, Martine ;
Duhamel, Alain ;
Faivre, Jean-Baptiste ;
Wallaert, Benoit ;
Remy, Jacques .
ACADEMIC RADIOLOGY, 2010, 17 (05) :587-594
[8]   Lung Perfusion with Dual-energy Multidetector-row CT (MDCT): Feasibility for the Evaluation of Acute Pulmonary Embolism in 117 Consecutive Patients [J].
Pontana, Francois ;
Faivre, Jean-Baptiste ;
Remy-Jardin, Martine ;
Flohr, Thomas ;
Schmidt, Bernhard ;
Tacelli, Nunzia ;
Pansini, Vittorio ;
Remy, Jacques .
ACADEMIC RADIOLOGY, 2008, 15 (12) :1494-1504
[9]   Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration [J].
Primak, A. N. ;
Ramirez Giraldo, J. C. ;
Liu, X. ;
Yu, L. ;
McCollough, C. H. .
MEDICAL PHYSICS, 2009, 36 (04) :1359-1369
[10]   Noninvasive differentiation of uric acid versus non-uric acid kidney stones using dual-energy CT [J].
Primak, Andrew N. ;
Fletcher, Joel G. ;
Vrtiska, Terri J. ;
Dzyubak, Oleksandr P. ;
Lieske, John C. ;
Jackson, Molly E. ;
Williams, James C., Jr. ;
McCollough, Cynthia H. .
ACADEMIC RADIOLOGY, 2007, 14 (12) :1441-1447