Comparison of field measurements and calculations of relative humidity and temperature in wood framed walls

被引:0
作者
Hagerstedt, S. Olof [1 ]
Arfvidsson, Jesper [1 ]
机构
[1] Lund Univ, Fac Engn, Dept Bldg Phys, POB 118, S-22100 Lund, Sweden
来源
THERMOPHYSICS 2010 | 2010年
关键词
Moisture; Wood framed hoses; WUFI; Relative humidity;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Energy efficient wood frame buildings give besides a number of positive effects also risks for moisture damages. To avoid moisture damage. in wood houses some parts of the Swedish construction industry use WUFI 1D calculation tool in the design phase. The purpose of this study is to demonstrate the coupling between measured and WUFI 1D calculated values of relative humidity and temperature. The first step presents a comparison between measurements and blind calculations of relative humidity and temperature at different positions in a wooden wall with an air gap. In the second step has boundary conditions for calculated values been adjusted in order to achieve better agreement. The result of the comparisons between calculated and measured values are analyzed. The general conclusion of this study is that it is of great importance to apply a correct airflow in air gap. Results also show that it is possible to obtain reliable calculated values with a proper flow in the air gap.
引用
收藏
页码:93 / 101
页数:9
相关论文
共 9 条
  • [1] FJELLSTROM P-A., 2010, VERIFICATION MEASURE
  • [2] GE SENSING, 2006, PROT HYGROTRAC WIR E
  • [3] HAGERSTEDT O., 2010, CALCULATION IN PRESS
  • [4] HOOGENBOOM C., 2009, GE SENSING REPORT CA
  • [5] IEA Annex 24, 1996, HEAT AIR MOISTURE TR
  • [6] Krus M., 1996, Moisture transport and storage coefficients of porous mineral building materials: theoretical principles and new test methods
  • [7] NEVANDER L-E., 2001, FUKT HANDBOK
  • [8] SMHI Swedish meteorological and hydrological institute, CLIM DAT KLIM
  • [9] WADSO L., 1996, TBBM5009 LUND U DEP