Design and Simulation of an Integrated Centrifugal Microfluidic Device for CTCs Separation and Cell Lysis

被引:45
|
作者
Nasiri, Rohollah [1 ,2 ,3 ]
Shamloo, Amir [1 ]
Akbari, Javad [1 ]
Tebon, Peyton [2 ,3 ]
Dokmeci, Mehmet R. [2 ,3 ,4 ]
Ahadian, Samad [2 ,3 ]
机构
[1] Sharif Univ Technol, Dept Mech Engn, Tehran 1136511155, Iran
[2] Univ Calif Los Angeles, Ctr Minimally Invas Therapeut C MIT, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
关键词
microfluidics; circulating tumor cells; cell separation; micromixer; cell lysis; CIRCULATING TUMOR-CELLS; CLASSIFICATION; OPTIMIZATION; MICROMIXER; PARTICLES;
D O I
10.3390/mi11070699
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Separation of circulating tumor cells (CTCs) from blood samples and subsequent DNA extraction from these cells play a crucial role in cancer research and drug discovery. Microfluidics is a versatile technology that has been applied to create niche solutions to biomedical applications, such as cell separation and mixing, droplet generation, bioprinting, and organs on a chip. Centrifugal microfluidic biochips created on compact disks show great potential in processing biological samples for point of care diagnostics. This study investigates the design and numerical simulation of an integrated microfluidic device, including a cell separation unit for isolating CTCs from a blood sample and a micromixer unit for cell lysis on a rotating disk platform. For this purpose, an inertial microfluidic device was designed for the separation of target cells by using contraction-expansion microchannel arrays. Additionally, a micromixer was incorporated to mix separated target cells with the cell lysis chemical reagent to dissolve their membranes to facilitate further assays. Our numerical simulation approach was validated for both cell separation and micromixer units and corroborates existing experimental results. In the first compartment of the proposed device (cell separation unit), several simulations were performed at different angular velocities from 500 rpm to 3000 rpm to find the optimum angular velocity for maximum separation efficiency. By using the proposed inertial separation approach, CTCs, were successfully separated from white blood cells (WBCs) with high efficiency (similar to 90%) at an angular velocity of 2000 rpm. Furthermore, a serpentine channel with rectangular obstacles was designed to achieve a highly efficient micromixer unit with high mixing quality (similar to 98%) for isolated CTCs lysis at 2000 rpm.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Microfluidic counterflow centrifugal elutriation system for sedimentation-based cell separation
    Morijiri, Tomoki
    Yamada, Masumi
    Hikida, Toshikatsu
    Seki, Minoru
    MICROFLUIDICS AND NANOFLUIDICS, 2013, 14 (06) : 1049 - 1057
  • [42] Recent Developments in Inertial and Centrifugal Microfluidic Systems along with the Involved Forces for Cancer Cell Separation: A Review
    Farahinia, Alireza
    Zhang, Wenjun
    Badea, Ildiko
    SENSORS, 2023, 23 (11)
  • [43] Novel simultaneous separation and detection of CTCs and PSA on an integrated multistage microfluidic chip for early diagnosis of prostate cancer
    Zhuo, Ying
    Wang, Yeru
    Gao, Rongke
    Zhan, Changbiao
    Liu, Hancheng
    Liu, Yiyuan
    Wang, Feifei
    Chen, Xiaozhe
    Feng, Yujie
    Yu, Liandong
    MICROCHEMICAL JOURNAL, 2025, 212
  • [44] Analysis of Electric Fields inside Microchannels and Single Cell Electrical Lysis with a Microfluidic Device
    Morshed, Bashir I.
    Shams, Maitham
    Mussivand, Tofy
    MICROMACHINES, 2013, 4 (02) : 243 - 256
  • [45] Highly integrated microfluidic device for cell pairing, fusion and culture
    He, Weihua
    Huang, Liang
    Feng, Yongxiang
    Liang, Fei
    Ding, Wei
    Wang, Wenhui
    BIOMICROFLUIDICS, 2019, 13 (05):
  • [46] Simulation guided design of a microfluidic device for electrophoretic stretching of DNA
    Hsieh, Chih-Chen
    Lin, Tsung-Hsien
    Huang, Chiou-De
    BIOMICROFLUIDICS, 2012, 6 (04):
  • [47] Continuous Cell Separation Using Microfluidic-Based Cell Retention Device with Alternative Boosted Flow
    Chen, Po-Hung
    Cheng, Yu-Ting
    Ni, Bing-Syuan
    Huang, Jen-Huang
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2020, 191 (01) : 151 - 163
  • [48] Continuous Cell Separation Using Microfluidic-Based Cell Retention Device with Alternative Boosted Flow
    Po-Hung Chen
    Yu-Ting Cheng
    Bing-Syuan Ni
    Jen-Huang Huang
    Applied Biochemistry and Biotechnology, 2020, 191 : 151 - 163
  • [49] Development of a microfluidic device for cell concentration and blood cell-plasma separation
    M. Sneha Maria
    B. S. Kumar
    T. S. Chandra
    A. K. Sen
    Biomedical Microdevices, 2015, 17
  • [50] Development of a microfluidic device for cell concentration and blood cell-plasma separation
    Maria, M. Sneha
    Kumar, B. S.
    Chandra, T. S.
    Sen, A. K.
    BIOMEDICAL MICRODEVICES, 2015, 17 (06) : 1 - 19