摘要
In computed tomography (CT), blurring occurs due to different hardware or software errors and hides certain medical details that are present in an image. Image blur is difficult to avoid in many circumstances and can frequently ruin an image. For this, many methods have been developed to reduce the blurring artifact from CT images. The problems with these methods are the high implementation time, noise amplification and boundary artifacts. Hence, this article presents an amended version of the iterative Landweber algorithm to attain artifact-free boundaries and less noise amplification in a faster application time. In this study, both synthetic and real blurred CT images are used to validate the proposed method properly. Similarly, the quality of the processed synthetic images is measured using the feature similarity index, structural similarity and visual information fidelity in pixel domain metrics. Finally, the results obtained from intensive experiments and performance evaluations show the efficiency of the proposed algorithm, which has potential as a new approach in medical image processing.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 29 条
  • [1] Sharpening enhancement of Computed Tomography (CT) images using Hyperbolic Secant Square filter
    Anand, S.
    Kumari, R. Shantha Selva
    [J]. OPTIK, 2013, 124 (15): : 2121 - 2124
  • [2] A statistical approach for MR and CT images comparison
    Andria, Gregorio
    Attivissimo, Filippo
    Lanzolla, Anna Maria Lucia
    [J]. MEASUREMENT, 2013, 46 (01) : 57 - 65
  • [3] A Technique to Improve the Image Quality in Computer Tomography
    Attivissimo, Filippo
    Cavone, Giuseppe
    Lanzolla, Anna Maria Lucia
    Spadavecchia, Maurizio
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (05) : 1251 - 1257
  • [4] A fast alternating minimization algorithm for total variation deblurring without boundary artifacts
    Bai, Zheng-Jian
    Cassani, Daniele
    Donatelli, Marco
    Serra-Capizzano, Stefano
    [J]. JOURNAL OF MATHEMATICAL ANALYSIS AND APPLICATIONS, 2014, 415 (01) : 373 - 393
  • [5] FILTERING CAPABILITIES AND CONVERGENCE OF THE VAN-CITTERT DECONVOLUTION TECHNIQUE
    BENNIA, A
    RIAD, SM
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1992, 41 (02) : 246 - 250
  • [6] Boas FE., 2012, IMAGING MED, V4, P229, DOI [DOI 10.2217/IIM.12.13, 10.2217/iim.12.13]
  • [7] A limited-angle CT reconstruction method based on anisotropic TV minimization
    Chen, Zhiqiang
    Jin, Xin
    Li, Liang
    Wang, Ge
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07) : 2119 - 2141
  • [8] Principles of CT: Radiation Dose and Image Quality
    Goldman, Lee W.
    [J]. JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2007, 35 (04) : 213 - 225
  • [9] Guo Q, 2012, INFORMATION-TOKYO, V15, P5159
  • [10] DAUBECHIES COMPLEX WAVELET TRANSFORM BASED MULTILEVEL SHRINKAGE FOR DEBLURRING OF MEDICAL IMAGES IN PRESENCE OF NOISE
    Khare, Ashish
    Tiwary, Uma Shanker
    Jeon, Moongu
    [J]. INTERNATIONAL JOURNAL OF WAVELETS MULTIRESOLUTION AND INFORMATION PROCESSING, 2009, 7 (05) : 587 - 604