A review of cone-beam CT applications for adaptive radiotherapy of prostate cancer

被引:60
|
作者
Posiewnik, M. [1 ]
Piotrowski, T. [2 ,3 ]
机构
[1] Gdynia Oncol Ctr, Dept Med Phys, Gdynia, Poland
[2] Poznan Univ Med Sci, Dept Electroradiol, Poznan, Poland
[3] Greater Poland Canc Ctr, Dept Med Phys, Poznan, Poland
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 59卷
关键词
IGRT; Adaptive radiotherapy; Cone-beam CT; Prostate cancer; IMAGE-GUIDED RADIOTHERAPY; QUALITY-ASSURANCE PROGRAM; ONLINE RE-OPTIMIZATION; COMPUTED-TOMOGRAPHY; GUIDANCE STRATEGIES; DOSE DISTRIBUTION; FIDUCIAL MARKERS; RECTAL DIAMETER; IMRT PLANS; CBCT;
D O I
10.1016/j.ejmp.2019.02.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: The aim of this study was to systematize the information on adaptive radiotherapy based on cone-beam computed tomography (CBCT) imaging for patients with prostate cancers including the prostate gland only, or the prostate gland and seminal vesicles region. Material and method: A systematic literature search was carried out using the PubMed engine, based upon the following terms: adaptive radiotherapy, intensity modulated radiotherapy, volumetric modulated arc therapy and image-guided and dose-guided radiotherapy. Overall, 58 relevant studies were included: 31 about on-line strategies of adaptation, 6 about off-line strategies, and 21 that highlighted the technical aspects of CBCT usage. Results: The off-line strategies provide a statistical prediction for each individual patient for the rest of treatment. The on-line strategies aim to resolve the potential disagreements between a planned and delivered dose directly before the specific fraction. Both strategies need information about the movements of the irradiated region relative to the target from treatment planning and the dose delivered relative to the planned dose. Quality of CBCT is very important for the accuracy of the adaptation procedures. While the errors caused by the insufficient quality of anatomy visualisation with CBCT are currently minimized, there are still problems with the proper dose computation. The most accurate methods are able to minimize the calculation error to 3%. Conclusion: CBCT plays a significant role in each step of adaptive radiation therapy of prostate cancers, starting from registration procedures through setting an appropriate CTV-to-PTV margin to fraction dose recalculations, and its cumulation/monitoring relative to the planned dose.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 50 条
  • [21] A study on adaptive IMRT treatment planning using kV cone-beam CT
    Ding, George X.
    Duggan, Dennis M.
    Coffey, Charles W.
    Deeley, Matthew
    Hallahan, Dennis E.
    Cmelak, Anthony
    Malcolm, Arnold
    RADIOTHERAPY AND ONCOLOGY, 2007, 85 (01) : 116 - 125
  • [22] Cone-Beam Computed Tomography-Guided Online Adaptive Radiotherapy: Promising Results for Bladder Cancer Case
    Azzarouali, Sana
    Goudschaal, Karin
    Visser, Jorrit
    Bel, Arjan
    Daniels, Laurien
    den Boer, Duncan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (09)
  • [23] Fractionated changes in prostate cancer radiotherapy using cone-beam computed tomography
    Huang, Tzung-Chi
    Chou, Kuei-Ting
    Yang, Shih-Neng
    Chang, Chih-Kai
    Liang, Ji-An
    Zhang, Geoffrey
    MEDICAL DOSIMETRY, 2015, 40 (03) : 222 - 225
  • [24] Reconstructing cone-beam CT with spatially varying qualities for adaptive radiotherapy: a proof-of-principle study
    Lu, Wenting
    Yan, Hao
    Gu, Xuejun
    Tian, Zhen
    Ouyang, Luo
    Yang, Liu
    Zhou, Linghong
    Cervino, Laura
    Wang, Jing
    Jiang, Steve
    Jia, Xun
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (20): : 6251 - 6266
  • [25] Incidence and evolution of imaging changes on cone-beam CT during and after radical radiotherapy for non-small cell lung cancer
    Clarke, Enrico
    Curtis, John
    Brada, Michael
    RADIOTHERAPY AND ONCOLOGY, 2019, 132 : 121 - 126
  • [26] Radiation Dose From Cone-Beam CT in Neuroradiology Applications
    Berris, Theocharis
    Gupta, Rajiv
    Rehani, Madan M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (04) : 755 - 761
  • [27] ADAPTIVE-PREDICTIVE ORGAN LOCALIZATION USING CONE-BEAM COMPUTED TOMOGRAPHY FOR IMPROVED ACCURACY IN EXTERNAL BEAM RADIOTHERAPY FOR BLADDER CANCER
    Lalondrelle, Susan
    Huddart, Robert
    Warren-Oseni, Karole
    Hansen, Vibeke Nordmark
    McNair, Helen
    Thomas, Karen
    Dearnaley, David
    Horwich, Alan
    Khoo, Vincent
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (03): : 705 - 712
  • [28] Building motion models of lung tumours from cone-beam CT for radiotherapy applications
    Martin, James
    McClelland, Jamie
    Yip, Connie
    Thomas, Christopher
    Hartill, Clare
    Ahmad, Shahreen
    O'Brien, Richard
    Meir, Ivan
    Landau, David
    Hawkes, David
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (06): : 1809 - 1822
  • [29] Beam characteristics and radiation output of a kilovoltage cone-beam CT
    Ding, George X.
    Coffey, Charles W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (17): : 5231 - 5248
  • [30] Comparison of low-dose, half-rotation, cone-beam CT with electronic portal imaging device for registration of fiducial markers during prostate radiotherapy
    Ung, Ngie Min
    Wee, Leonard
    Hackett, Sara Lyons
    Jones, Andrew
    Lim, Tee Sin
    Harper, Christopher Stirling
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 171 - 181