Subcellular carrier-based optical ion-selective nanosensors

被引:14
作者
Carregal-Romero, Susana
Montenegro, Jose-Maria
Parak, Wolfgang J.
Riveragil, Pilar [1 ]
机构
[1] Univ Marburg, Dept Biophoton, Inst Phys, D-35037 Marburg, Germany
关键词
molecular imaging; cells; non-invasive; ions; sensors; colloidal nanoparticles; polyelectrolyte multilayer capsules; optical read-out; SURFACE-CHARGE; AMPHIPHILIC POLYMER; CELLULAR UPTAKE; POLYELECTROLYTE MICROCAPSULES; BULK OPTODES; NANOPARTICLES; PH; FLUORESCENCE; CAPSULES; NANOCRYSTALS;
D O I
10.3389/fphar.2012.00070
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
In this review, two carrier systems based on nanotechnology for real-time sensing of biologically relevant analytes (ions or other biological molecules) inside cells in a non-invasive way are discussed. One system is based on inorganic nanoparticles with an organic coating, whereas the second system is based on organic microcapsules. The sensor molecules presented within this work use an optical read-out. Due to the different physicochemical properties, both sensors show distinctive geometries that directly affect their internalization patterns. The nanoparticles carry the sensor molecule attached to their surfaces whereas the microcapsules encapsulate the sensor within their cavities. Their different size (nano and micro) enable each sensors to locate in different cellular regions. For example, the nanoparticles are mostly found in endolysosomal compartments but the microcapsules are rather found in phagolysosomal vesicles. Thus, allowing creating a tool of sensors that sense differently. Both sensor systems enable to measure ratiometrically however, only the microcapsules have the unique ability of multiplexing. At the end, an outlook on how more sophisticated sensors can be created by confining the nano-scaled sensors within the microcapsules will be given.
引用
收藏
页数:7
相关论文
共 85 条
[1]   How Colloidal Nanoparticles Could Facilitate Multiplexed Measurements of Different Analytes with Analyte-Sensitive Organic Fluorophores [J].
Abbasi, Azhar Zahoor ;
Amin, Faheem ;
Niebling, Tobias ;
Friede, Sebastian ;
Ochs, Markus ;
Carregal-Romero, Susana ;
Montenegro, Jose-Maria ;
Gil, Pilar Rivera ;
Heimbrodt, Wolfram ;
Parak, Wolfgang J. .
ACS NANO, 2011, 5 (01) :21-25
[2]   Au@pNIPAM Colloids as Molecular Traps for Surface-Enhanced, Spectroscopic, Ultra-Sensitive Analysis [J].
Alvarez-Puebla, Ramon A. ;
Contreras-Caceres, Rafael ;
Pastoriza-Santos, Isabel ;
Perez-Juste, Jorge ;
Liz-Marzan, Luis M. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2009, 48 (01) :138-143
[3]   Assembly of dendrimers with redox-active [{CpFe(μ3-CO)}4] clusters at the periphery and their application to oxo-anion and adenosine-5′-triphosphate sensing [J].
Aranzaes, JR ;
Belin, C ;
Astruc, D .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2006, 45 (01) :132-136
[4]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[5]   A fluorescence affinity hollow fiber sensor for continuous transdermal glucose monitoring [J].
Ballerstadt, R ;
Schultz, JS .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4185-4192
[6]   Layer-By-Layer-Assembled Capsules and Films for Therapeutic Delivery [J].
Becker, Alisa L. ;
Johnston, Angus P. R. ;
Caruso, Frank .
SMALL, 2010, 6 (17) :1836-1852
[7]   Core-referenced ratiometric fluorescent potassium ion sensors using self-assembled ultrathin films on europium nanoparticles [J].
Brown, JQ ;
McShane, MJ .
IEEE SENSORS JOURNAL, 2005, 5 (06) :1197-1205
[8]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[9]   Core/shell fluorescent silica nanopartictes for chemical sensing: Towards single-particle laboratories [J].
Burns, A ;
Sengupta, P ;
Zedayko, T ;
Baird, B ;
Wiesner, U .
SMALL, 2006, 2 (06) :723-726
[10]  
CAMERON IL, 1980, CANCER RES, V40, P1493