Evaluation strategies for isotope ratio measurements of single particles by LA-MC-ICPMS

被引:41
作者
Kappel, S. [1 ]
Boulyga, S. F. [2 ]
Dorta, L. [4 ]
Guenther, D. [4 ]
Hattendorf, B. [4 ]
Koffler, D. [3 ]
Laaha, G. [3 ]
Leisch, F. [3 ]
Prohaska, T. [1 ]
机构
[1] Univ Nat Resources & Life Sci, Dept Chem, Div Analyt Chem, VIRIS Lab, A-3430 Vienna, Tulln An Der Do, Austria
[2] IAEA, Safeguards Analyt Serv, Dept Safeguards, A-1400 Vienna, Austria
[3] Univ Nat Resources & Life Sci, Dept Landscape Spatial & Infrastruct Sci, Inst Appl Stat & Comp, A-1180 Vienna, Austria
[4] ETH, Swiss Fed Inst Technol Zurich, Dept Chem & Appl Biosci, Inorgan Chem Lab, CH-8093 Zurich, Switzerland
基金
奥地利科学基金会;
关键词
U isotope ratios; Laser ablation MC-ICPMS; Single particles; Short transient signals; Data evaluation strategies; Finite mixture model; PLASMA-MASS SPECTROMETRY; TRANSIENT SIGNALS; PRECISION; URANIUM; MS; CHROMATOGRAPHY; SAMPLES; SR;
D O I
10.1007/s00216-012-6674-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Data evaluation is a crucial step when it comes to the determination of accurate and precise isotope ratios computed from transient signals measured by multi-collector-inductively coupled plasma mass spectrometry (MC-ICPMS) coupled to, for example, laser ablation (LA). In the present study, the applicability of different data evaluation strategies (i.e. 'point-by-point', 'integration' and 'linear regression slope' method) for the computation of U-235/U-238 isotope ratios measured in single particles by LA-MC-ICPMS was investigated. The analyzed uranium oxide particles (i.e. 9073-01-B, CRM U010 and NUSIMEP-7 test samples), having sizes down to the sub-micrometre range, are certified with respect to their U-235/U-238 isotopic signature, which enabled evaluation of the applied strategies with respect to precision and accuracy. The different strategies were also compared with respect to their expanded uncertainties. Even though the 'point-by-point' method proved to be superior, the other methods are advantageous, as they take weighted signal intensities into account. For the first time, the use of a 'finite mixture model' is presented for the determination of an unknown number of different U isotopic compositions of single particles present on the same planchet. The model uses an algorithm that determines the number of isotopic signatures by attributing individual data points to computed clusters. The U-235/U-238 isotope ratios are then determined by means of the slopes of linear regressions estimated for each cluster. The model was successfully applied for the accurate determination of different U-235/U-238 isotope ratios of particles deposited on the NUSIMEP-7 test samples.
引用
收藏
页码:2943 / 2955
页数:13
相关论文
共 45 条
[1]   Multiple linear regression and on-line ion exchange chromatography for alternative Rb-Sr and Nd-Sm MC-ICP-MS isotopic measurements [J].
Angel Rodriguez-Castrillon, J. ;
Garcia-Ruiz, Silvia ;
Moldovan, Mariella ;
Garcia Alonso, J. Ignacio .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (04) :611-618
[2]  
[Anonymous], 2008, UNC MEAS 3
[3]  
[Anonymous], 2012, R LANG ENV STAT COMP
[4]  
[Anonymous], 2000, EURACHEM CITAC GUID
[5]  
Aregbe Y, 2011, ESARDA B, V46, P136
[6]   Use of data from environmental sampling for IAEA safeguards. Case study: uranium with near-natural 235U abundance [J].
Axelsson, A. ;
Fischer, D. M. ;
Penkin, M. V. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (03) :725-729
[7]   Determining the isotopic compositions of uranium and fission products in radioactive environmental microsamples using laser ablation ICP-MS with multiple ion counters [J].
Boulyga, Sergei F. ;
Prohaska, Thomas .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (02) :531-539
[8]   Implementation of Guide to the expression of Uncertainty in Measurement (GUM) to multi-collector TIMS uranium isotope ratio metrology [J].
Buerger, S. ;
Essex, R. M. ;
Mathew, K. J. ;
Richter, S. ;
Thomas, R. B. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 294 (2-3) :65-76
[9]   A new approach to single shot laser ablation analysis and its application to in situ Pb/U geochronology [J].
Cottle, J. M. ;
Horstwood, M. S. A. ;
Parrish, R. R. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (10) :1355-1363
[10]   MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38