Modulating the optical fiber sensor of Laser Doppler Anemometry for measuring the chicken blood velocity

被引:2
|
作者
Chen, Yung-Chung [1 ]
Chen, Zhao-g Chen [2 ]
Lu, Tung-Wu [3 ]
Chen, Chien-Ming [2 ]
机构
[1] Shu Te Univ, Dept Ind Management, 59 Hun Shan Rd, Kaohsiung 824, Taiwan
[2] Natl Taipei Univ Technol, Dept Electro Opt Engn, Taipei 106, Taiwan
[3] Natl Taiwan Univ, Inst Biomed Engn, Taipei 106, Taiwan
来源
EXPERIMENTAL MECHANICS IN NANO AND BIOTECHNOLOGY, PTS 1 AND 2 | 2006年 / 326-328卷
关键词
Laser Doppler Anemometry; fiber optical system; rectangle case; honeycomb;
D O I
10.4028/www.scientific.net/KEM.326-328.1355
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We designed a new module of Laser Doppler Anemometry (LDA) with fiber optical system, which is mainly comprised of a laser diode, optical fibers and a two dimensional (2D) photodetcctor. The fiber optical system involved a laser diode (VCSEL, Copax Inc.) with 850 nm wavelength, single mode fiber (Prime Optical Fiber Inc.), half Coupler and two fiber collimators. The 2D photodetector made by silicon PIN photodiode is aligned between the two collimators with 39 degrees beams cross an-le and all the components were set into a rectangle case, which have coin's size and can be accommodated by two same set of these components. We added anticoagulant and antiseptic into fresh chicken blood and diluted it with normal saline, and then Put the diluted blood into a beaker with a motor in the liquid. The diluted blood was pumped by the motor into an aqueduct which is connected to glass aqueduct, and back to the beaker to form a circulation system. In the experiments, we evaluate the relationships among the blood cell velocity and diameter of glass tube, temperature variation of blood, and concentrations of blood. By analyzing the results of these experiments, the main factor that affects the precision of velocity measurement is the cross angle of two injected laser beams and the intensity of scattering light. The module constructed by optical fiber light can precisely measure the velocity of blood flow at most 5% error.
引用
收藏
页码:1355 / +
页数:2
相关论文
共 50 条
  • [1] Measurment of chicken blood velocity using Dual Beam mode of Laser Doppler Anemometry by optical fiber module
    Chen, CM
    Chen, GL
    2005 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS (LEOS), 2005, : 886 - 887
  • [2] LASER DOPPLER ANEMOMETRY - A NONINTRUSIVE OPTICAL MEASURING TECHNIQUE FOR FLUID VELOCITY
    RUCK, B
    PARTICLE CHARACTERIZATION, 1987, 4 (01): : 26 - 37
  • [3] BLOOD VELOCITY-MEASUREMENT BY FIBER OPTIC LASER DOPPLER ANEMOMETRY
    KILPATRICK, D
    TYBERG, JV
    PARMLEY, WW
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1982, 29 (02) : 142 - 145
  • [4] A NEW LASER DOPPLER VELOCIMETRY WITH AN OPTICAL FIBER FOR MEASURING THE VELOCITY PROFILE OF ARTERIAL BLOOD-FLOW
    MITO, K
    HOKI, N
    TOMONAGA, G
    HIRAMATSU, O
    KAGIYAMA, M
    KAJIYA, F
    NISHIHARA, H
    BIORHEOLOGY, 1981, 18 (01) : 160 - 161
  • [5] BLOOD VELOCITY-MEASUREMENT BY LASER DOPPLER VELOCIMETRY WITH OPTICAL FIBER
    IMAMURA, M
    KAJIYA, F
    HOKI, N
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (05): : 987 - 987
  • [6] BLOOD VELOCITY-MEASUREMENT BY LASER DOPPLER METHOD WITH OPTICAL FIBER
    IMAMURA, M
    HOKI, N
    KAJIYA, F
    BIORHEOLOGY, 1979, 16 (06) : 492 - 492
  • [7] Measurement of the acoustic velocity by Laser Doppler Anemometry
    Loizeau, T
    Gervais, Y
    ACUSTICA, 1997, 83 (06): : 945 - 954
  • [8] Measurement of the acoustic velocity by laser Doppler anemometry
    Loizeau, Thierry
    Gervais, Yves
    Acta Acustica (Stuttgart), 1997, 83 (06): : 945 - 954
  • [9] APPLICATION OF LASER DOPPLER ANEMOMETRY TO FIBER SUSPENSIONS
    EK, R
    SVENSK PAPPERSTIDNING-NORDISK CELLULOSA, 1979, 82 (02): : 30 - 31