Variability in Baseball Throwing Metrics During a Structured Long-Toss Program: Does One Size Fit All or Should Programs Be Individualized?

被引:23
作者
Leafblad, Nels D. [1 ]
Larson, Dirk R. [2 ]
Fleisig, Glenn S. [3 ]
Conte, Stan [4 ]
Fealy, Stephen A. [5 ]
Dines, Joshua S. [5 ]
D'Angelo, John [6 ]
Camp, Christopher L. [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, 200 First St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Hlth Sci Res, Rochester, MN 55905 USA
[3] Amer Sports Med Inst, Birmingham, AL USA
[4] Conte Injury Analyt, Santa Clara, CA USA
[5] Hosp Special Surg, Sports Med & Shoulder Serv, 535 E 70th St, New York, NY 10021 USA
[6] Major League Baseball, Off Commissioner, New York, NY USA
来源
SPORTS HEALTH-A MULTIDISCIPLINARY APPROACH | 2019年 / 11卷 / 06期
关键词
long-toss; elbow torque; ball velocity; interthrower reliability; intrathrower reliability; TORQUE; MECHANICS; INJURY;
D O I
10.1177/1941738119869945
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background: The variability of throwing metrics, particularly elbow torque and ball velocity, during structured long-toss programs is unknown. Hypothesis: (1) Elbow torque and ball velocity would increase as throwers progressed through a structured long-toss program. (2) Intrathrower reliability would be high while interthrower reliability would be variable. Study Design: Descriptive laboratory study. Methods: Sixty healthy high school and collegiate pitchers participated in a structured long-toss program while wearing a validated inertial measurement unit, which measured arm slot, arm velocity, shoulder rotation, and elbow varus torque. Ball velocity was assessed by radar gun. These metrics were compared within and between all pitchers at 90, 120, 150, and 180 ft, and maximum effort mound pitching. Intra- and interthrower reliabilities were calculated for each metric at every stage of the program. Results: Ball velocity significantly changed at each progressive throwing distance, but elbow torque did not. Pitching from the mound did not place more torque on the elbow than long-toss throwing from 120 ft and beyond. Intrathrower reliability was excellent (intraclass correlation coefficient >0.75) throughout the progressive long-toss program, especially on the mound. Ninety-one percent of throwers had acceptable interthrower reliability (coefficient of variation <5%) for ball velocity, whereas only 79% of throwers had acceptable interthrower reliability for elbow torque. Conclusion: Based on trends in elbow torque, it may be practical to incorporate pitching from the mound earlier in the program (once a player is comfortable throwing from 120 ft). Ball velocity and elbow torque do not necessarily correlate with one another, so a degree of caution should be exercised when using radar guns to estimate elbow torque. Given the variability in elbow torque between throwers, some athletes would likely benefit from an individualized throwing program. Clinical Relevance: Increased ball velocity does not necessarily equate to increased elbow torque in long-toss. Some individuals would likely benefit from individualized long-toss programs for rehabilitation.
引用
收藏
页码:535 / 542
页数:8
相关论文
共 18 条
  • [1] Correlation of Throwing Mechanics With Elbow Valgus Load in Adult Baseball Pitchers
    Aguinaldo, Arnel L.
    Chambers, Henry
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (10) : 2043 - 2048
  • [2] Correlation of Torque and Elbow Injury in Professional Baseball Pitchers
    Anz, Adam W.
    Bushnell, Brandon D.
    Griffin, Leah Passmore
    Noonan, Thomas J.
    Torry, Michael R.
    Hawkins, Richard J.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2010, 38 (07) : 1368 - 1374
  • [3] Data-Based Interval Throwing Programs for Baseball Players
    Axe, Michael
    Hurd, Wendy
    Snyder-Mackler, Lynn
    [J]. SPORTS HEALTH-A MULTIDISCIPLINARY APPROACH, 2009, 1 (02): : 145 - 153
  • [4] Axe MJ, 2002, J ATHL TRAINING, V37, P194
  • [5] Development of a distance-based interval throwing program for little league aged athletes
    Axe, MJ
    SnyderMackler, L
    Konin, JG
    Strube, MJ
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1996, 24 (05) : 594 - 602
  • [6] MEASUREMENT OF UPPER EXTREMITY TORQUE PRODUCTION AND ITS RELATIONSHIP TO THROWING SPEED IN THE COMPETITIVE ATHLETE
    BARTLETT, LR
    STOREY, MD
    SIMONS, BD
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (01) : 89 - 91
  • [7] The Relationship of Throwing Arm Mechanics and Elbow Varus Torque Within-Subject Variation for Professional Baseball Pitchers Across 82,000 Throws
    Camp, Christopher L.
    Tubbs, Travis G.
    Fleisig, Glenn S.
    Dines, Joshua S.
    Dines, David M.
    Altchek, David W.
    Dowling, Brittany
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2017, 45 (13) : 3030 - 3035
  • [8] Cicchetti D. V., 1994, PSYCHOL ASSESSMENTS, V6, P284, DOI [10.1037/1040-3590.6.4.284, DOI 10.1037/1040-3590.6.4.284]
  • [9] Escamilla Rafael, 2002, Sports Biomech, V1, P213, DOI 10.1080/14763140208522798
  • [10] Differences Among Overhand, 3-Quarter, and Sidearm Pitching Biomechanics in Professional Baseball Players
    Escamilla, Rafael F.
    Slowik, Jonathan S.
    Diffendaffer, Alek Z.
    Fleisig, Glenn S.
    [J]. JOURNAL OF APPLIED BIOMECHANICS, 2018, 34 (05) : 377 - 385