Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry

被引:277
作者
Pepose, Jay S.
Feigenbaum, Susan K.
Qazi, Mujtaba A.
Sanderson, Jeffrey P.
Roberts, Cynthia J.
机构
[1] Pepose Vis Inst, Chesterfield, MO 63017 USA
[2] Washington Univ, Sch Med, Dept Ophthalmol & Visual Sci, St Louis, MO 63110 USA
[3] Univ Missouri, Dept Econ, Columbia, MO 65211 USA
[4] Ohio State Univ, Dept Ophthalmol & Biomed Engn Dept, Columbus, OH USA
关键词
D O I
10.1016/j.ajo.2006.09.036
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the preoperative and postoperative measurement of corneal biomechanical properties and intraocular pressure (IOP) using Goldmann applanation tonometry (GAT), the ocular response analyzer (ORA), and the Pascal dynamic contour tonometer (PDCT) in eyes undergoing myopic laser in situ keratomileusis (LASIK). DESIGN: Prospective, nonrandomized clinical trial. METHODS: IOP was measured in 66 myopic eyes before and after LASIK by GAT, ORA, and PDCT in a randomized sequence. Metrics of corneal biomechanical properties (corneal hysteresis [CH], corneal resistance factor [CRF], and ocular pulse amplitude [OPA]) were recorded. RESULTS: After LASIK, there was a reduction in mean corneal pachymetry of 90.2 mu m and in IOP measurements with GAT (Delta = -1.8 +/- 2.8 mm Hg; P < .01), ORA,Goldmann (Delta = -4.6 +/- 2.8 mm Hg, P < .01), and ORA-corneal compensated (Delta - 2.1 +/- 2.6 mm Hg; P < .05). However, there was no statistically significant difference between preoperative and postoperative IOP measurements taken by PDCT (Delta = -0.5 +/- 2.6 mm Hg). Postoperatively, CRF decreased by 28.6% (P < .01), CH by 16.2% (P < .01), and OPA by 1.8% (P = .32). CONCLUSIONS: Measurement of IOP with PDCT appears to be relatively immune to changes in corneal biomechanics and pachymetry after LASIK, in comparison to GAT and ORA measures of IOP. PDCT and ORA both showed statistically lower variation in measurement than GAT. LASIK produced a marked declinein CH and CRF, which may reflect respective changes in the viscous and elastic qualities of the post,LASIK cornea. In contrast, there was no statistical change in OPA.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 35 条
[1]  
Agudelo LM, 2002, J REFRACT SURG, V18, P472
[2]   Underestimation of intraocular pressure in eyes after laser in situ keratomileusis [J].
Arimoto, A ;
Shimizu, K ;
Shoji, N ;
Enomoto, K ;
Kohara, M .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2002, 46 (06) :645-649
[3]  
Baypaktar S, 2005, EUR J OPHTHALMOL, V15, P81
[4]   Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS) [J].
Brandt, JD ;
Beiser, JA ;
Kass, MA ;
Gordon, MO .
OPHTHALMOLOGY, 2001, 108 (10) :1779-1788
[5]   Change in Intraocular pressure measurements after LASIK - The effect of the refractive correction and the lamellar flap [J].
Chang, DH ;
Stulting, RD .
OPHTHALMOLOGY, 2005, 112 (06) :1009-1016
[6]   Intraocular pressure measurement in patients with previous LASIK surgery using pressure phosphene tonometer [J].
Cheng, ACK ;
Leung, DYL ;
Cheung, EYY ;
Fan, DSP ;
Law, RWK ;
Lam, DSC .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 33 (02) :153-157
[7]   The preoperative intraocular pressure level predicts the amount of underestimated intraocular pressure after LASIK for myopia [J].
Chihara, E ;
Takahashi, H ;
Okazaki, K ;
Park, M ;
Tanito, M .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (02) :160-164
[8]   Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach [J].
Doughty, MJ ;
Zaman, ML .
SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) :367-408
[9]   Dynamic contour tonometry for post-LASIK intraocular pressure measurements [J].
Duba, I ;
Wirthlin, AC .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2004, 221 (05) :347-350
[10]   Tonometry after laser in situ keratomileusis treatment [J].
Duch, S ;
Serra, A ;
Castanera, J ;
Abos, R ;
Quintana, M .
JOURNAL OF GLAUCOMA, 2001, 10 (04) :261-265