Possible Influences on the Interpretation of Functional Domain (FD) Near-Infrared Spectroscopy (NIRS): An Explorative Study

被引:6
|
作者
Celie, Bert M. [1 ]
Boone, Jan [1 ,2 ]
Dumortier, Jasmien [1 ]
Derave, Wim [1 ]
De Backer, Tine [3 ]
Bourgois, Jan G. [1 ,2 ]
机构
[1] Univ Ghent, Dept Movement & Sports Sci, B-9000 Ghent, Belgium
[2] Ghent Univ Hosp, Ctr Sports Med, Ghent, Belgium
[3] Ghent Univ Hosp, Dept Cardiol, Ghent, Belgium
关键词
Near-infrared spectroscopy; NIRS; Subcutaneous adipose tissue thickness; ATT; Blood flow; Physiological calibration; FEMORAL BLOOD-GASES; MUSCLE DEOXYGENATION; INCREMENTAL HANDGRIP; UPTAKE KINETICS; SKELETAL; OXYGENATION; EXERCISE; FLOW; LEG; VASODILATATION;
D O I
10.1177/0003702815620562
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The influence of subcutaneous adipose tissue (ATT) and oxygen (O-2) delivery has been poorly defined in frequency domain (FD) near-infrared spectroscopy (NIRS). Therefore, the aim of this study was to investigate the possible influence of these variables on all FD NIRS responses using a reliable protocol. Moreover, these influences were also investigated when using relative oxy- and deoxyhemoglobin and -myoglobin (oxy[Hb+Mb] and deoxy[Hb+Mb]) values (in %). A regression analysis was carried out for ATT and maximal-minimum oxy[Hb+Mb], deoxy[Hb+Mb], oxygen saturation (SmO2), and total hemoglobin (totHb) amplitudes during an incremental cyclic contraction protocol (ICCP) in a group of 45 participants. Moreover, the same analysis was carried out between subcutaneous ATT and the relative oxy- and deoxy[Hb+Mb] values (in %). In the second part of this study, a regression analysis was performed for peak forearm blood flow (FBF) during ICCP and the absolute and relative NIRS values in a group of 37 participants. Significant exponential correlation coefficients were found between ATT and deoxy[Hb+Mb] (r = 0.53; P<0.001), oxy[Hb+Mb] (r = 0.57; P<0.001), and SmO2 amplitudes (r = 0.57; P<0.001). No significant relations were found between ATT and relative oxy[Hb+Mb] (r = 0.37; P = 0.07) and deoxy[Hb+Mb] (r = 0.09; P = 0.82). Significant positive correlation coefficients were found between force at exhaustion and maximal FBF (r = 0.66; P<0.001), maximal differences in deoxy[Hb+Mb] (r = 0.353; P = 0.032) and totHb (r = 0.512; P = 0.002) while no significant correlation coefficients were found between these maximal force values and maximal differences in oxy[Hb+Mb] (r = -0.267; P = 0.111) and SmO2 (r = -0.267; P = 0.111). Significant linear correlation coefficients were found between FBF and deoxy[Hb+Mb] (r = 0.51; P = 0.001), oxy[Hb+Mb] (r = -0.50; P = 0.001), SmO2 (r = -0.54; P = 0.001), and totHb amplitude (r = 0.61; P<0.001). No significant correlations were found when using relative oxy[Hb+Mb] (r = -0.01; P = 0.957) and deoxy[Hb+Mb] (r = -0.02; P = 0.895). Based on these findings, caution is advised when using NIRS values, as subcutaneous ATT and O-2 delivery significantly influence NIRS measurements. To eliminate these influences, use of relative deoxy[Hb+Mb] is advised, especially in clinical settings or in people with a higher subcutaneous ATT layer.
引用
收藏
页码:363 / 371
页数:9
相关论文
共 50 条
  • [41] The Potential Role of Functional Near-Infrared Spectroscopy as Clinical Biomarkers in Schizophrenia
    Chou, Po-Han
    Huang, Chun-Jun
    Sun, Chia-Wei
    CURRENT PHARMACEUTICAL DESIGN, 2020, 26 (02) : 201 - 217
  • [42] Functional near-infrared spectroscopy as a window to cardiovascular health
    Lyde, Elizabeth
    Wang, Xinlong
    Liu, Hanli
    Nguyen, Kytai
    Fadel, Paul
    Alexandrakis, George
    CLINICAL AND TRANSLATIONAL NEUROPHOTONICS 2019, 2019, 10864
  • [43] EXTRACEREBRAL ABSORPTION OF NEAR-INFRARED LIGHT INFLUENCES THE DETECTION OF INCREASED CEREBRAL OXYGENATION MONITORED BY NEAR-INFRARED SPECTROSCOPY
    GERMON, TJ
    YOUNG, AER
    MANARA, AR
    NELSON, RJ
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1995, 58 (04) : 477 - 479
  • [44] Transformer Model for Functional Near-Infrared Spectroscopy Classification
    Wang, Zenghui
    Zhang, Jun
    Zhang, Xiaochu
    Chen, Peng
    Wang, Bing
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (06) : 2559 - 2569
  • [45] Effects of Tongue Pressure on Cerebral Blood Volume Dynamics: A Functional Near-Infrared Spectroscopy Study
    Miyata, Hidemasa
    Tani, Ryouji
    Toratani, Shigeaki
    Okamoto, Tetsuji
    BRAIN SCIENCES, 2022, 12 (02)
  • [46] Mini-Review of Studies Testing the Cardiorespiratory Hypothesis With Near-Infrared Spectroscopy (NIRS): Overview and Perspectives
    Agbangla, Nounagnon Frutueux
    Maillot, Pauline
    Vitiello, Damien
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [47] A Systematic Review of the Application of Functional Near-Infrared Spectroscopy to the Study of Cerebral Hemodynamics in Healthy Aging
    Michael K. Yeung
    Agnes S. Chan
    Neuropsychology Review, 2021, 31 : 139 - 166
  • [48] Functional Near-Infrared Spectroscopy in neurodegenerative disease: a review
    Xie, Lei
    Liu, Yong
    Gao, Yuling
    Zhou, Jiaqi
    FRONTIERS IN NEUROSCIENCE, 2024, 18
  • [49] Bilateral connectivity in the somatosensory region using near-infrared spectroscopy (NIRS) by wavelet coherence
    Rojas, Raul Fernandez
    Huang, Xu
    Ou, Keng-Liang
    SPIE BIOPHOTONICS AUSTRALASIA, 2016, 10013
  • [50] Near-infrared spectroscopy (NIRS) as a tool to monitor exhaust air from poultry operations
    Druckenmueller, Katharina
    Guenther, Klaus
    Elbers, Gereon
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 630 : 536 - 543