EIS of carburised CoCrMo: Evolution of parameters characterising the metal-electrolyte interface

被引:11
作者
Cassar, Josianne [1 ]
Mallia, Bertram [1 ]
Karl, Andreas [2 ]
Buhagiar, Joseph [1 ]
机构
[1] Univ Malta, Dept Met & Mat Engn, MSD-2080 Msida, Malta
[2] Bodycote Hardiff GmbH, Landsberg, Germany
关键词
EIS; CoCrMo alloy; S-phase; Low temperature carburising; Expanded austenite; Corrosion; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; BIOMEDICAL ALLOYS; STAINLESS-STEEL; PASSIVE FILM; CO-CR; BEHAVIOR; TEMPERATURE; CORROSION; ADSORPTION;
D O I
10.1016/j.surfcoat.2016.03.033
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Corrosion-wear is of major concern for Cobalt-Chromium-Molybdenum (CoCrMo) hip implants as it leads to premature failure of the prosthesis and treating the CoCrMo surface using low temperature carburising treatment is a plausible investigation to mitigate such problem. This diffusion treatment introduces a supersaturated carbon solid solution, termed S-phase, which hardens the CoCrMo without detriment to the corrosion resistance. There are only basic studies on the electrochemical characteristics of S-phase surface and therefore, from a scientific and industrial point of view, there is a lot of scope to investigate it further. This research uses electrochemical impedance spectroscopy (EIS) to study the metal/electrolyte interface and how it changes after carburising and over a time span of 24 h. The technique reveals that the CoCrMo/Ringer's solution interface contains a highly resistant passive film and an electrical double layer when under equilibrium conditions. Comparison of the impedance results attained when testing untreated and carburised CoCrMo reveals that the treated metal has a passive film which has higher polarisation resistance compared to that of the untreated alloy. This may have been a consequence of the fact that the treated metal's passive film has lower time constant dispersion and faster film growth kinetics compared to the untreated alloy's passive film. In addition, both untreated and carburised interfaces suffer a considerable loss in their polarisation resistance after 20 h of testing which indicates a non-monotonic relationship between passive film impedance and electrochemical potential. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 98
页数:9
相关论文
共 36 条
[1]   On the physical interpretation of constant phase elements [J].
Abouzari, M. R. Shoar ;
Berkemeier, F. ;
Schmitz, G. ;
Wilmer, D. .
SOLID STATE IONICS, 2009, 180 (14-16) :922-927
[2]   Surface property enhancement of Ni-free medical grade austenitic stainless steel by low-temperature plasma carburising [J].
Buhagiar, Joseph ;
Qian, Linmao ;
Dong, Hanshan .
SURFACE & COATINGS TECHNOLOGY, 2010, 205 (02) :388-395
[3]   Metal release from hip prostheses: cobalt and chromium toxicity and the role of the clinical laboratory [J].
Campbell, Jonathon R. ;
Estey, Mathew P. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (01) :213-220
[4]   Influence of microstructure of HC CoCrMo biomedical alloys on the corrosion and wear behaviour in simulated body fluids [J].
Casaban Julian, Leandre ;
Igual Munoz, Anna .
TRIBOLOGY INTERNATIONAL, 2011, 44 (03) :318-329
[5]   MEDICAL DEVICES How safe are metal-on-metal hip implants? [J].
Cohen, Deborah .
BRITISH MEDICAL JOURNAL, 2012, 344
[6]  
Conti Malcolm Caligari, 2014, Biomatter, V4, pe27713, DOI 10.4161/biom.27713
[7]   Electrochemical impedance spectroscopy study of the adsorption behaviour of α-lactalbumin and β-casein at stainless steel [J].
Cosman, NP ;
Fatih, K ;
Roscoe, SG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 574 (02) :261-271
[8]  
Davies AP, 2005, J BONE JOINT SURG BR, V87B, P1439, DOI 10.1302/0301-620X.87B10
[9]   Surgical Variables Influence Metal Ion Levels After Hip Resurfacing [J].
Desy, Nicholas M. ;
Bergeron, Stephane G. ;
Petit, Alain ;
Huk, Olga L. ;
Antoniou, John .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (06) :1635-1641
[10]  
Diard JP., 2012, HDB ELECTROCHEMICAL