Electrochemiluminescent Chemosensors for Clinical Applications: A Review

被引:32
作者
Cuong Khac Phu Truong [1 ]
Thao Dang Duy Nguyen [1 ]
Shin, Ik-Soo [1 ,2 ]
机构
[1] Soongsil Univ, Dept ICMC Convergence Technol, 369 Sangdo Ro, Seoul 06978, South Korea
[2] Soongsil Univ, Coll Nat Sci, Dept Chem, 369 Sangdo Ro, Seoul 06978, South Korea
基金
新加坡国家研究基金会;
关键词
Electrochemiluminescence; chemosensors; clinical applications; luminophore; coreactant; ANTHRYLAZAMACROCYCLE CONJUGATE PROBES; CHELATION-ENHANCED FLUORESCENCE; CARBON NITRIDE NANOSHEETS; RESONANCE ENERGY-TRANSFER; ALKALI-METAL ION; ELECTROGENERATED CHEMILUMINESCENCE; SELECTIVE DETECTION; BIOMARKER DETECTION; MOLECULAR SENSORS; HYPOCHLOROUS ACID;
D O I
10.1007/s13206-019-3301-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Economic development has raised concerns about human healthcare and disease prevention from its early stages. In that regard, the detection of biomarkers is crucial for early diagnosis of diseases, and it is an essential tool for managing various health conditions. The clinical diagnostics industry is worth hundreds of billions of dollars and has been expanding. However, the traditional methods for biomarkers detection are high-cost and time-consuming. Also, they usually require highly trained personnel and complex instrumental processes, only providing a centralized medical diagnosis system in large hospitals or specialized facilities. In contrast, a chemosensor is a smart molecular analytical device designed to sense an analyte to generate a detectable signal and to offer direct diagnosis without complex instruments or systems. Moreover, electrochemiluminescence (ECL) possesses distinct advantages such as low-costs, simplicity, and portability. ECL has become a useful technique and has been widely applied in many fields, from basic research to practical applications. Chemosensors coupled with ECL can provide compelling advantages over conventional approaches, such as rapid response time, higher sensitivity, and selectivity. This minireview aims to highlight recent representative studies on ECL-based chemosensors for clinical applications. It provides a general overview of the design and structure of ECL-based chemosensors, and also covers the general problems and challenges. The presented content may prove to be useful for discovering new sensor concepts or extension of existing biomarker detection strategies.
引用
收藏
页码:203 / 216
页数:14
相关论文
共 98 条
[1]   CHELATION-ENHANCED FLUORESCENCE OF ANTHRYLAZAMACROCYCLE CONJUGATE PROBES IN AQUEOUS-SOLUTION [J].
AKKAYA, EU ;
HUSTON, ME ;
CZARNIK, AW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (09) :3590-3593
[2]  
[Anonymous], CHEMOSENS ION MOL RE
[3]  
[Anonymous], RSC ADV
[4]  
Bard A.J., 2004, Electrogenerated Chemiluminescence
[5]  
Bard A. J., 2000, ELECTROCHEMICAL METH
[6]   PHOTOINDUCED ELECTRON-TRANSFER AS A GENERAL DESIGN LOGIC FOR FLUORESCENT MOLECULAR SENSORS FOR CATIONS [J].
BRYAN, AJ ;
DE SILVA, AP ;
DESILVA, SA ;
RUPASINGHE, RADD ;
SANDANAYAKE, KRAS .
BIOSENSORS, 1989, 4 (03) :169-179
[7]   A ruthenium(II) complex-based lysosome-targetable multisignal chemosensor for in vivo detection of hypochlorous acid [J].
Cao, Liyan ;
Zhang, Run ;
Zhang, Wenzhu ;
Du, Zhongbo ;
Liu, Chunjun ;
Ye, Zhiqiang ;
Song, Bo ;
Yuan, Jingli .
BIOMATERIALS, 2015, 68 :21-31
[8]   An iridium(III)-based lab-on-a-molecule for cysteine/homocysteine and tryptophan using triple-channel interrogation [J].
Chen, Kun ;
Schmittel, Michael .
ANALYST, 2013, 138 (22) :6742-6745
[9]   Fluorescent Chemosensors Based on Spiroring-Opening of Xanthenes and Related Derivatives [J].
Chen, Xiaoqiang ;
Pradhan, Tuhin ;
Wang, Fang ;
Kim, Jong Seung ;
Yoon, Juyoung .
CHEMICAL REVIEWS, 2012, 112 (03) :1910-1956
[10]   Fluorescence 'on-off-on' chemosensor for the sequential recognition of Hg2+ and cysteine in water [J].
Choi, Ye Won ;
Lee, Jae Jun ;
You, Ga Rim ;
Kim, Cheal .
RSC ADVANCES, 2015, 5 (48) :38308-38315