Serum and urine metal levels in patients with metal-on-metal surface arthroplasty

被引:87
|
作者
Skipor, AK
Campbell, PA
Patterson, LM
Anstutz, HC
Schmalzried, TP
Jacobs, JJ
机构
[1] Rush Presbyterian St Lukes Med Ctr, Dept Orthoped Surg, Chicago, IL 60612 USA
[2] Orthoped Hosp, Joint Replacement Inst, Los Angeles, CA 90007 USA
关键词
D O I
10.1023/A:1021179029640
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The resurgence of metal-on-metal articulating surfaces for hip arthroplasty has also heightened concerns about the degree and magnitude of metal particle generation and the accompanying increase in circulating metal ion concentrations. In this study, we measured the concentration of chromium in serum and urine and the concentration of cobalt in serum in twenty-five patients with modern metal-on-metal surface arthroplasty of the hip in a prospective manner. The results showed that the mean post-operative chromium in serum levels were 22-fold, 23-fold and 21-fold higher at 3, 6 and 12 months post-operative, respectively, than pre-operative levels. The mean post-operative cobalt in serum levels were 8-fold, 7-fold and 6-fold higher at 3, 6 and 12 months post-operative, respectively, than pre-operative levels. The mean post-operative chromium in urine levels were 9-fold, 10-fold and 14-fold higher at 3, 6 and 12 months post-operative, respectively, than pre-operative levels. The values seen in this study with the current generation of surface arthroplasties are: (a) lower than those seen in an earlier generation of surface arthroplasties; (b) in the same range as those observed in association with metal-on-metal conventional total hip replacements, which typically have smaller head sizes; (c) higher than values observed in patients with conventional metal-on-polyethylene articulating couples. (C) 2002 Kluwer Academic Publishers.
引用
收藏
页码:1227 / 1234
页数:8
相关论文
共 50 条
  • [21] Chronological changes of serum chromium levels after modern metal-on-metal total hip arthroplasty
    Maezawa, K
    Nozawa, M
    Matsuda, K
    Yasuma, M
    Mori, K
    Enomoto, F
    Ogawa, S
    Shitoto, K
    Kurosawa, H
    ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (04): : 422 - 426
  • [22] The release of metals from metal-on-metal surface arthroplasty of the hip
    Iavicoli, Ivo
    Falcone, Gianluca
    Alessandrelli, Maria
    Cresti, Rafaella
    De Santis, Vincenzo
    Salvatori, Stefano
    Alimonti, Alessandro
    Carelli, Giovanni
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2006, 20 (01) : 25 - 31
  • [23] Metal-on-Metal Total Hip Arthroplasty
    Kim, Raymond H.
    Dennis, Douglas A.
    Carothers, Joshua T.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (07): : 44 - 46
  • [24] Metal-on-Metal Total Hip Arthroplasty
    Malviya, Ajay
    Ramaskandhan, Jayasree
    Holland, James P.
    Lingard, Elizabeth A.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (07): : 1675 - 1683
  • [25] The Effect of Acetabular Inclination on Metal Ion Levels Following Metal-on-Metal Hip Arthroplasty
    Emmanuel, Andrew R.
    Bergin, Karen M.
    Kelly, Gabrielle E.
    McCoy, Gerald F.
    Wozniak, Andrew P.
    Quinlan, John F.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (01): : 186 - 191
  • [26] Metal-on-metal hip resurfacing arthroplasty
    Shimmin, Andrew
    Beaule, Paul E.
    Campbell, Pat
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (03): : 637 - 654
  • [27] Differences in concentration of metal debris in blood, serum, and plasma samples of patients with metal-on-metal hip resurfacing arthroplasty
    Khan, M.
    Kuiper, J. H.
    Sieniawska, Christine
    Richardson, J. B.
    JOURNAL OF ORTHOPAEDICS, 2016, 13 (04) : 450 - 454
  • [28] Metal ion hypersensitivity in metal-on-metal hip arthroplasty
    Park, Y. -S.
    Moon, Y. -W.
    Lim, S. -J.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2006, : 57 - +
  • [29] Early Markers of Nephrotoxicity in Patients With Metal-on-metal Hip Arthroplasty
    Corradi, Massimo
    Daniel, Joseph
    Ziaee, Hena
    Alinovi, Rossella
    Mutti, Antonio
    McMinn, Derek J. W.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (06) : 1651 - 1659
  • [30] Serum Chromium Levels Before and After Revision Surgery for Loosened Metal-On-Metal Total Hip Arthroplasty
    Maezawa, Katsuhiko
    Nozawa, Masahiko
    Matsuda, Keiji
    Sugimoto, Munehiko
    Shitoto, Katsuo
    Kurosawa, Hisashi
    JOURNAL OF ARTHROPLASTY, 2009, 24 (04): : 549 - 553