Structure characterization of petroleum vacuum residues by in-beam EI Fourier transform ion cyclotron resonance mass spectrometry

被引:13
|
作者
Miyabayashi, K [1 ]
Naito, Y [1 ]
Tsujimoto, K [1 ]
Miyake, M [1 ]
机构
[1] JAIST, Sch Mat Sci, Tatsunokuchi, Ishikawa 9231292, Japan
关键词
FT-ICR; in-beam EI; vacuum residue; complex mixture analysis;
D O I
10.1016/S1387-3806(02)00897-7
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A n-heptane soluble fraction (AH-VR-Sa) of Arabian heavy vacuum residues (AH-VR) has been analyzed by in-beam electron ionization Fourier transform ion cyclotron resonance mass spectrometry (EI FT-ICR MS). The probe temperature and the ionization energy of in-beam EI were independently adjusted to expand the detectable range of peaks originating from components of AH-VR-Sa and to prevent fragmentation of the molecular ions. The upper mass limit of the peaks was extended to m/z = 700 when the probe temperature and the ionization energy were set to 300degreesC and 30 eV, respectively. The average molecular weight of the spectrum increased by an increase in the probe temperature. The molecular formulas of compounds in AH-VR-Sa were determined essentially based on accurate mass measurements. Major components of being characterized were hydrocarbons both with and without one sulfur atom. The compound type estimated on the basis of hydrogen-deficiency index Z (CnH2n+Z) was discussed. The strongest peaks of hydrocarbons with sulfur atom showed the Z value of - 10. The compound type analysis indicates that sulfur atom may be located at an aromatic ring but not at a side chain. The effect of experimental conditions on the detectable compound type distribution was also discussed. The present results demonstrate that the characterization of vacuum residues by in-beam El FF-ICR MS is advantageous over the conventional EI Fr-ICR MS in the detectable range of peaks and in the versatility for samples. In-beam El FT-ICR MS is useful as a complementary method to characterize vacuum residues by electrospray ionization (ESI) FT-ICR MS, since ESI cannot ionize hydrocarbons with high Z values. (Int J Mass Spectrom 221 (2002) 93-105) (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:93 / 105
页数:13
相关论文
共 50 条
  • [21] Speciation and chemical composition of petroleum crude oil by Fourier transform ion cyclotron resonance mass spectrometry
    Marshall, Alan
    Corilo, Yuri
    Hendrickson, Christopher
    Putman, Jonathan
    Krajewski, Logan
    Smith, Donald
    Wesibrod, Chad
    Rodgers, Ryan
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [22] Characterization of Saturated Hydrocarbons in Vacuum Petroleum Residua: Redox Derivatization Followed by Negative-Ion Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    Zhou, Xibin
    Zhang, Yahe
    Zhao, Suoqi
    Chung, Keng H.
    Xu, Chunming
    Shi, Quan
    ENERGY & FUELS, 2014, 28 (01) : 417 - 422
  • [23] Quantitation of ion abundances in Fourier transform ion cyclotron resonance mass spectrometry
    Goodner, KL
    Milgram, KE
    Williams, KR
    Watson, CH
    Eyler, JR
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (11) : 1204 - 1212
  • [24] Fourier Transform Ion Cyclotron Resonance Mass Spectrometry Applications for Metabolomics
    Cochran, Darcy
    Powers, Robert
    BIOMEDICINES, 2024, 12 (08)
  • [25] Charge Reversal Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    Lobodin, Vladislav V.
    Savory, Joshua J.
    Kaiser, Nathan K.
    Dunk, Paul W.
    Marshall, Alan G.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (02) : 213 - 221
  • [26] 40 years of Fourier transform ion cyclotron resonance mass spectrometry
    Marshall, Alan G.
    Chen, Tong
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 377 : 410 - 420
  • [27] Charge reversal fourier transform ion cyclotron resonance mass spectrometry
    Marshall, A.G. (marshall@magnet.fsu.edu), 1600, Springer Science and Business Media, LLC (24):
  • [28] Protein research by Fourier Transform Ion Cyclotron Resonance mass spectrometry
    Janis, J.
    Kemia-Kemi/Finnish Chemical Journal, 2000, 27 (02): : 98 - 102
  • [29] Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    Hendrickson, CL
    Emmett, MR
    ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 1999, 50 : 517 - 536
  • [30] Fourier transform ion cyclotron resonance mass spectrometry: State of the art
    Marshall, Alan G.
    Chen, Tong
    Blakney, Greg T.
    Hendrickson, Christopher L.
    Kaiser, Nathan K.
    McKenna, Amy M.
    Rodgers, Ryan P.
    Weisbrod, Chad R.
    Young, Nicolas L.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247