Adjustment of creatinine clearance improves accuracy of Calvert's formula for carboplatin dosing

被引:48
|
作者
Ando, Y
Minami, H
Saka, H
Ando, M
Sakai, S
Shimokata, K
机构
[1] NAGOYA UNIV, SCH MED, DEPT INTERNAL MED 1, SHOWA KU, NAGOYA, AICHI 466, JAPAN
[2] SHINSHIRO MUNICIPAL HOSP, DEPT INTERNAL MED, SHINSHIRO, AICHI 44113, JAPAN
[3] NATL CANC CTR HOSP E, DEPT HEMATOL ONCOL, KASHIWA, CHIBA 277, JAPAN
[4] JAPANESE RED CROSS NAGOYA FIRST HOSP, DEPT INTERNAL MED, NAKAMURA KU, NAGOYA, AICHI 453, JAPAN
[5] NAGOYA UNIV, SCH MED, CLIN PREVENT SERV, SHOWA KU, NAGOYA, AICHI 466, JAPAN
关键词
carboplatin; pharmacokinetics; chemotherapy; glomerular filtration rate; creatinine clearance;
D O I
10.1038/bjc.1997.509
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Carboplatin clearance depends on the glomerular filtration rate (GFR), and Calvert's formula is frequently used to achieve a target area under the time vs concentration curve (mg ml(-1) min). Creatinine clearance is a substitute for GFR when creatinine Values are determined by the Jaffe method, which is being replaced by the enzymatic method. When the enzymatic method is used, the corresponding creatinine clearance theoretically exceeds GFR, and the use of creatinine clearance as GFR in Calvert's formula results, accordingly, in overdosing of carboplatin. In this study, we have established a model for adjusting the creatinine clearance to offset this bias based on a relationship between creatinine values measured by the Jaffe method and by the enzymatic method: adjusted creatinine clearance (ml min(-1)) = creatinine clearance (mi min(-1)) x [serum creatinine (mg dl(-1))]/[serum creatinine (mg dl(-1)) + 0.2]. Subsequently, we Validated this model using the data from 35 lung cancer patients. Estimated clearances of carboplatin with the original equation [creatinine clearance + 25] were systematically higher than observed clearances [mean prediction error (MPE) +/- standard error (s.e.) = 26 +/- 5%]. This positive bias was corrected by the adjustment (MPE +/- s.e. = 5 +/- 4%). When the enzymatic method is used, the adjusted creatinine clearance should be used in Calvert's formula.
引用
收藏
页码:1067 / 1071
页数:5
相关论文
共 7 条
  • [1] Adjustment of creatinine clearance for carboplatin dosing in Calvert's formula and clinical efficacy for lung cancer
    Hatta, Takahiro
    Hase, Tetsunari
    Hara, Toru
    Kimura, Tomoki
    Kojima, Eiji
    Abe, Takashi
    Horio, Yoshitsugu
    Goto, Yasuhiro
    Ozawa, Naoya
    Yogo, Naoyuki
    Shibata, Hirofumi
    Shimokata, Tomoya
    Oguri, Tetsuya
    Yamamoto, Masashi
    Yanagisawa, Kiyoshi
    Ando, Masahiko
    Ando, Yuichi
    Kondo, Masashi
    Ishii, Makoto
    Hasegawa, Yoshinori
    CANCER MEDICINE, 2023, 12 (15): : 15955 - 15969
  • [2] Evaluation of Calvert's formula for dosage adjustment of carboplatin in Japanese patients with hormone refractory prostate cancer
    Sato, Eriko
    Yano, Ikuko
    Jiko, Mari
    Takahashi, Kazushige
    Motohashi, Hideyuki
    Masuda, Satohiro
    Katsura, Toshiya
    Nishiyama, Hiroyuki
    Segawa, Takehiko
    Ito, Noriyuki
    Kamoto, Toshiyuki
    Ogawa, Osamu
    Inui, Ken-ichi
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2006, 29 (07) : 1441 - 1444
  • [3] Evaluation of carboplatin dosing in non-small cell lung carcinoma patients using Calvert formula and Cockroft and Gault equation for glomerular filtration rate estimation
    Bar-Sela, Gil
    Kaidar-Person, Orit
    Mari, Fadi
    Assady, Suheir
    Haim, Nissim
    ONCOLOGY LETTERS, 2012, 4 (05) : 1072 - 1076
  • [4] AUC of Calvert's formula in targeted intra-arterial carboplatin chemoradiotherapy for cancer of the oral cavity
    Oya, R
    Nakamura, S
    Ikemura, K
    Takagi, S
    Mugino, H
    BRITISH JOURNAL OF CANCER, 2004, 90 (11) : 2062 - 2066
  • [5] AUC of Calvert's formula in targeted intra-arterial carboplatin chemoradiotherapy for cancer of the oral cavity
    R Oya
    S Nakamura
    K Ikemura
    S Takagi
    H Mugino
    British Journal of Cancer, 2004, 90 : 2062 - 2066
  • [6] Carboplatin dosing in the era of IDMS-creatinine; the Cockroft-Gault formula no longer provides a sufficiently accurate estimate of glomerular filtration rate for routine use in clinical care
    McLean, Luke
    Whittle, James R.
    Graham, Jonathan
    Ismail, Huda
    Lichtenstein, Meir
    Hicks, Rodney J.
    McNally, Orla
    Herschtal, Alan
    Rosenthal, Mark
    Rischin, Danny
    Hamilton, Anne
    GYNECOLOGIC ONCOLOGY, 2020, 157 (03) : 793 - 798
  • [7] Correlation between glomerular filtration rate with gamma camera and estimated serum creatinine clearance from Cockcroft and Gault's formula
    Bhushan, Shivanand
    Kumar, Rajesh
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2012, 27 (02): : 85 - 88