Effectiveness of ultrasound for the destruction of Mycobacterium sp strain (6PY1)

被引:36
作者
Al Bsoul, Abeer [1 ]
Magnin, Jean-Pierre [1 ]
Commenges-Bernole, Nadine [1 ]
Gondrexon, Nicolas [1 ]
Willison, John [2 ]
Petrier, Christian [1 ]
机构
[1] LEPMI, F-38402 St Martin Dheres, France
[2] CEA, IRTSV LCBM, F-38054 Grenoble 9, France
关键词
Ultrasound; Destruction; Mycobacterium; 6PY1; SONOCHEMISTRY; DISINFECTION; INACTIVATION; CAVITATION; SONICATION; FREQUENCY; PYRENE; WATER;
D O I
10.1016/j.ultsonch.2009.04.005
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound is widely used to disinfect drinking water and wastewater due to its strong physical and chemical effects on microorganisms. The aim of this study was to investigate the effect of ultrasound on the destruction of Mycobacterium strain 6PY1. Ultrasound waves (20 kHz or 612 kHz) were used to treat aqueous suspensions of Mycobacterium at different volumes, initial bacterial concentrations. and power densities. At the same power density and the same exposure time, sonication at high frequency resulted in a lower destruction of Mycobacterium sp. 6PY1 (35.5%) than sonication at low frequency (93%). The percentage of removal was not significantly affected by the volume of the irradiated suspension (150-300 ml) or the initial cell concentration (2.15 x 10(-3) - 1.4 x 10(-2) mg protein L(-1)). At low frequency, the removal percentage of Mycobacterium sp. 6PY1 increased with increasing the power density, with a constant level reached after a certain power density. At high frequency, the removal percentage of Mycobacterium sp. 6PY1 increased with increasing the power density. The mechanism of cell killing was investigated by examining the effects of OH(center dot) radical scavengers Such as sodium carbonate. At high frequency the presence of sodium carbonate suppressed the removal process. However, at low frequency the removal process was not affected, thus indicating that OH(center dot) radicals have a negligible role in this case. The latter result was supported by ten time's H(2)O(2) production at high frequency greater than that at low frequency. (C) 2009 Published by Elsevier B.V.
引用
收藏
页码:106 / 110
页数:5
相关论文
共 19 条
[1]  
Chendke P. K., 1974, Chemical Engineering Journal, V8, P165, DOI 10.1016/0300-9467(74)85022-7
[2]   COMMENTS ON THE EVOLVING FIELD OF SONOCHEMISTRY BY A CAVITATION PHYSICIST [J].
CRUM, LA .
ULTRASONICS SONOCHEMISTRY, 1995, 2 (02) :S147-S152
[4]  
DEHGHANI MH, 2005, AM J ENV SCI, V3, P187
[5]   Inactivation of Escherichia coli by sonication at discrete ultrasonic frequencies [J].
Hua, I ;
Thompson, JE .
WATER RESEARCH, 2000, 34 (15) :3888-3893
[6]  
HUGHES DE, 1961, J BIOCHEM MICROBIOL, V4, P405
[7]   The development and evaluation of ultrasound for the treatment of bacterial suspensions.: A study of frequency, power and sonication time on cultured Bacillus species [J].
Joyce, E ;
Phull, SS ;
Lorimer, JP ;
Mason, TJ .
ULTRASONICS SONOCHEMISTRY, 2003, 10 (06) :315-318
[8]   Water disinfection by acoustic and hydrodynamic cavitation [J].
Jyoti, KK ;
Pandit, AB .
BIOCHEMICAL ENGINEERING JOURNAL, 2001, 7 (03) :201-212
[9]   Identification of pyrene-induced proteins in Mycobacterium sp strain 6PY1:: Evidence for two ring-hydroxylating dioxygenases [J].
Krivobok, S ;
Kuony, S ;
Meyer, C ;
Louwagie, M ;
Willison, JC ;
Jouanneau, Y .
JOURNAL OF BACTERIOLOGY, 2003, 185 (13) :3828-3841
[10]   FACTORS INFLUENCING THE INFECTIVITY OF GIARDIA-MURIS CYSTS FOLLOWING OZONE INACTIVATION IN LABORATORY AND NATURAL-WATERS [J].
LABATIUK, CW ;
BELOSEVIC, M ;
FINCH, GR .
WATER RESEARCH, 1992, 26 (06) :733-743