Tibial component in total knee replacement : the effect of overhang and sizing on outcome

被引:0
|
作者
Foubert, Knud [1 ,2 ]
Heylen, Steven [1 ,2 ]
Plaeke, Philip [1 ,3 ]
Somville, Johan [1 ,2 ]
Nicolai, Paul [1 ,4 ]
机构
[1] NHS West Suffolk Hosp, Hardwick Lane, Bury St Edmunds IP33 2QZ, Suffolk, England
[2] Antwerp Univ Hosp, Dept Orthopaed, Wilrijkstr 10, B-2650 Edegem, Belgium
[3] Antwerp Univ Hosp, Dept Surg, Edegem, Belgium
[4] NHS West Suffolk Hosp, Dept Orthopaed, Bury St Edmunds, Suffolk, England
来源
ACTA ORTHOPAEDICA BELGICA | 2017年 / 83卷 / 04期
关键词
Total knee arthroplasty; tibial component; oversizing; lateral overhang;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of this study was to find a relationship between tibial overhang, malpositioning and oversizing, and the functional outcome. 188 patients were included in this retrospective study. All patients completed an Oxford knee score questionnaire at mean follow-up of 5 years. Anteroposterior radiographs of the total knee replacements were reviewed for medial and lateral overhang and oversizing. Lateral overhang was seen in 32.9% of patients with a mean Oxford knee score of 24.7. However lateral overhang proved no significant correlation with the functional outcome. Oversizing was seen in 31.9% of patients and, with a mean of 25.6, oversizing did have a correlation with Oxford Knee score. This studs confirms that neither medial or lateral overhang of the tibial component influences functional outcome, independent of the severity of overhang. Oversizing the tibial component however, does show worse functional outcome scores at a 5 year review.
引用
收藏
页码:659 / 663
页数:5
相关论文
共 50 条
  • [31] Accuracy of anatomical references used for rotational alignment of tibial component in total knee arthroplasty
    Namık Şahin
    Teoman Atıcı
    Alpaslan Öztürk
    Güven Özkaya
    Yüksel Özkan
    Bülent Avcu
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 565 - 570
  • [32] Can Isolated Tibial Component Revision Be an Alternative to Isolated Aseptic Loosening of the Tibial Component in Total Knee Arthroplasty?
    Rodriguez-Merchan, E. Carlos
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2024, 12 (02): : 136 - 138
  • [33] Malrotated Tibial Component Increases Medial Collateral Ligament Tension in Total Knee Arthroplasty
    Kuriyama, Shinichi
    Ishikawa, Masahiro
    Furu, Moritoshi
    Ito, Hiromu
    Matsuda, Shuichi
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2014, 32 (12) : 1658 - 1666
  • [34] Internal rotation of the tibial component in total knee arthroplasty can lead to extension deficit
    Mohammad Kamal Abdelnasser
    Mohammad Muath Adi
    Ahmed Aly Elnaggar
    Samih Tarabichi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 2948 - 2952
  • [35] Accuracy of anatomical references used for rotational alignment of tibial component in total knee arthroplasty
    Sahin, Namik
    Atici, Teoman
    Ozturk, Alpaslan
    Ozkaya, Guven
    Ozkan, Yuksel
    Avcu, Bulent
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (03) : 565 - 570
  • [36] Tibial component coverage affects tibial bone resorption and patient-reported outcome measures for patients following total knee arthroplasty
    Changquan Liu
    Guanglei Zhao
    Kangming Chen
    Jinyang Lyu
    Jie Chen
    Jingsheng Shi
    Gangyong Huang
    Feiyan Chen
    Yibing Wei
    Siqun Wang
    Jun Xia
    Journal of Orthopaedic Surgery and Research, 16
  • [37] Tibial Component Alignment After Total Knee Arthroplasty with Intramedullary Instrumentation: A Prospective Analysis
    Talmo, Carl T.
    Cooper, Andrew J.
    Wuerz, Tom
    Lang, Jason E.
    Bono, James V.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (08) : 1209 - 1215
  • [38] Combined femoral and tibial component total knee arthroplasty device rotation measurement is reliable and predicts clinical outcome
    Hernandez-Hermoso, Jose A.
    Nescolarde, Lexa
    Yanez-Siller, Federico
    Calle-Garcia, Juan
    Garcia-Perdomo, Damian
    Perez-Andres, Ricard
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2023, 24 (01)
  • [39] Combined femoral and tibial component total knee arthroplasty device rotation measurement is reliable and predicts clinical outcome
    José A. Hernández-Hermoso
    Lexa Nescolarde
    Federico Yañez-Siller
    Juan Calle-García
    Damian Garcia-Perdomo
    Ricard Pérez-Andres
    Journal of Orthopaedics and Traumatology, 24
  • [40] Can Achilles tendon be used as a new distal landmark for coronal tibial component alignment in total knee replacement surgery? An observational MRI study
    Tiftikci, Ugur
    Serbest, Sancar
    Burulday, Veysel
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2017, 13 : 81 - 86