A comparison of parametric and nonparametric approaches to ROC analysis of quantitative diagnostic tests

被引:96
|
作者
HajianTilaki, KO
Hanley, JA
Joseph, L
Collet, JP
机构
[1] MCGILL UNIV,DEPT EPIDEMIOL & BIOSTAT,MONTREAL,PQ H3A 1A2,CANADA
[2] ROYAL VICTORIA HOSP,DIV CLIN EPIDEMIOL,MONTREAL,PQ H3A 1A1,CANADA
[3] MONTREAL GEN HOSP,DIV CLIN EPIDEMIOL,MONTREAL,PQ H3G 1A4,CANADA
[4] JEWISH GEN HOSP,DIV CLIN EPIDEMIOL,MONTREAL,PQ,CANADA
关键词
ROC analysis; quantitative diagnostic test; comparison; parametric; binormal model; LABROC; nonparametric procedure; area under the curve (AUC);
D O I
10.1177/0272989X9701700111
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Receiver operating characteristic (ROG) analysis, which yields indices of accuracy such as the area under the curve (AUG), is increasingly being used to evaluate the performances of diagnostic tests that produce results on continuous scales. Both parametric and nonparametric ROC approaches are available to assess the discriminant capacity of such tests, but there are no clear guidelines as to the merits of each, particularly with non-binormal data. investigators may worry that when data are non-Gaussian, estimates of diagnostic accuracy based on a binormal model may be distorted. The authors conducted a Monte Carte simulation study to compare the bias and sampling variability in the estimates of the AUCs derived from parametric and nonparametric procedures. Each approach was assessed in data sets generated from various configurations of pairs of overlapping distributions; these included the binormal model and non-binormal pairs of distributions where one or both pair members were mixtures of Gaussian (MG) distributions with different degrees of departures from bi-normality. The biases in the estimates of the AUCs were found to be very small for both parametric and nonparametric procedures. The two approaches yielded very close estimates of the AUCs and of the corresponding sampling variability even when data were generated from non-binormal models. Thus, for a wide range of distributions, concern about bias or imprecision of the estimates of the AUC should not be a major factor in choosing between the nonparametric and parametric approaches.
引用
收藏
页码:94 / 102
页数:9
相关论文
共 50 条
  • [41] Comparison and parametric study of two theoretical modeling approaches based on an air-to-water thermoelectric generator system
    Luo, Ding
    Wang, Ruochen
    Yu, Wei
    JOURNAL OF POWER SOURCES, 2019, 439
  • [42] The use of receiver operating characteristic (ROC) analysis to assess the diagnostic value of serum amyloid A, haptoglobin and fibrinogen in traumatic reticuloperitonitis in cattle
    Nazifi, Saeed
    Ansari-Lari, Maryam
    Asadi-Fardaqi, Javad
    Rezaei, Maqsoud
    VETERINARY JOURNAL, 2009, 182 (02): : 315 - 319
  • [43] RECEIVER OPERATING CHARACTERISTIC ANALYSIS - A USEFUL METHOD FOR A COMPARISON OF THE CLINICAL RELEVANCE OF 2 IN-VITRO IGE TESTS
    DEBLAY, F
    ZANA, H
    OFFNER, M
    VEROT, A
    VELTEN, M
    PAULI, G
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1993, 92 (02) : 255 - 263
  • [44] Systematic comparison of local approaches for isotopically nonstationary metabolic flux analysis
    Huss, Sebastian
    Nikoloski, Zoran
    FRONTIERS IN PLANT SCIENCE, 2023, 14
  • [45] Quantitative angiography prognosis of intracranial aneurysm treatment failure using parametric imaging and distal vessel analysis
    Wisniewski, Alexander G.
    Bhurwani, Mohammad Mahdi Shiraz
    Sommer, Kelsey N.
    Monteiro, Andre
    Baig, Ammad
    Davies, Jason
    Siddiqui, Adnan
    Ionita, Ciprian N.
    MEDICAL IMAGING 2022: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2022, 12036
  • [46] Site Response Analysis (SRA): A Practical Comparison Among Different Dimensional Approaches
    Flores Lopez, Francisco Alonso
    Ayes Zamudio, Juan Carlos
    Vargas Moreno, Carlos Omar
    Vazquez Vazquez, Alejandro
    FROM FUNDAMENTALS TO APPLICATIONS IN GEOTECHNICS, 2015, : 1041 - 1048
  • [47] BAP1 immunohistochemistry and p16 FISH results in combination provide higher confidence in malignant pleural mesothelioma diagnosis: ROC analysis of the two tests
    Hida, Tomoyuki
    Hamasaki, Makoto
    Matsumoto, Shinji
    Sato, Ayuko
    Tsujimura, Tohru
    Kawahara, Kunimitsu
    Iwasaki, Akinori
    Okamoto, Tatsuro
    Oda, Yoshinao
    Honda, Hiroshi
    Nabeshima, Kazuki
    PATHOLOGY INTERNATIONAL, 2016, 66 (10) : 563 - 570
  • [48] Quantitative parametric analysis of contrast-enhanced lesions in dynamic MR mammography [Quantitative parametrische analyse der kontrastkinetik von läsionen in der dynamischen MR-mammographie]
    Hauth E.A.M.
    Jaeger H.
    Maderwald S.
    Mühler A.
    Kimmig R.
    Forsting M.
    Der Radiologe, 2008, 48 (6): : 593 - 600
  • [49] Vibalizer:: A free, web-based tool for rapid, quantitative comparison and analysis of calculated vibrational modes
    Grafton, Anthony K.
    JOURNAL OF COMPUTATIONAL CHEMISTRY, 2007, 28 (07) : 1290 - 1305
  • [50] Comparison of flow cytometry and image morphometry in the quantitative analysis of cell population markers in the lymph node of sheep
    Gunnes, G
    Valheim, M
    Press, CM
    Tverdal, A
    Storset, A
    VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 2003, 94 (3-4) : 177 - 183