Acquisition Times in Magnetic Resonance Imaging: Optimization in Clinical Use

被引:32
作者
Andria, Gregorio [1 ]
Attivissimo, Filippo [1 ]
Cavone, Giuseppe [1 ]
Lanzolla, Anna Maria Lucia [1 ]
机构
[1] Polytech Univ Bari, Dept Elect & Elect, I-70125 Bari, Italy
关键词
Biological tissues; biomedical signal analysis; image segmentation; magnetic resonance imaging (MRI); optimization methods; simulation; time-optimal control; MRI; SELECTION; CONTRAST;
D O I
10.1109/TIM.2009.2016888
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nuclear magnetic resonance imaging is a routine clinical system used for whole-body patient scanning that provides 3-D images. Recent technological innovations have encouraged the use of this technology for noninvasive coronary, heart, and chest investigation or for research applications, but the image quality of this technique depends on several factors. Some parameters are linked to the apparatus designed to acquire the magnetic resonance image, whereas others can be controlled by the user. In this paper, the authors analyze the software-controlled magnetic-resonance-imaging parameters to reduce the health examination acquisition time by assuring a good quality of the images. This objective is of fundamental importance to both increase the number of clinical tests produced with this equipment and to reduce the radiation doses in the patients. For this purpose, the parameters that influence the time acquisition and the signal-to-noise ratio were investigated, and a software platform for optimizing the imaging acquisition time was developed.
引用
收藏
页码:3140 / 3148
页数:9
相关论文
共 39 条
[1]  
ANDRIA G, 2008, P I2MTC VANC BC CAN, P1179
[2]   A TRANSFORMATION METHOD FOR THE RECONSTRUCTION OF FUNCTIONS FROM NONUNIFORMLY SPACED SAMPLES [J].
CLARK, JJ ;
PALMER, MR ;
LAWRENCE, PD .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1985, 33 (05) :1151-1165
[3]   Design and construction of a realistic digital brain phantom [J].
Collins, DL ;
Zijdenbos, AP ;
Kollokian, V ;
Sled, JG ;
Kabani, NJ ;
Holmes, CJ ;
Evans, AC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (03) :463-468
[4]   LARGE-ANGLE SPIN-ECHO IMAGING [J].
DIIORIO, G ;
BROWN, JJ ;
BORRELLO, JA ;
PERMAN, WH ;
SHU, HH .
MAGNETIC RESONANCE IMAGING, 1995, 13 (01) :39-44
[5]   DETERMINING CURRENT DISTRIBUTIONS FOR RF RESONATORS IN MAGNETIC-RESONANCE-IMAGING [J].
FORBES, LK ;
CROZIER, S ;
DODDRELL, DM .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (03) :284-292
[6]   OPTIMUM GEOMETRY OF SADDLE SHAPED COILS FOR GENERATING A UNIFORM MAGNETIC FIELD [J].
GINSBERG, DM ;
MELCHNER, MJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1970, 41 (01) :122-&
[7]  
HARRIS FJ, 1978, P IEEE, V66, P51, DOI 10.1109/PROC.1978.10837
[8]  
Hendrik R. E., 2001, RADIOLOGY, V156, P749
[9]  
Hennig J, 2000, MAGNET RESON MED, V44, P983, DOI 10.1002/1522-2594(200012)44:6<983::AID-MRM23>3.0.CO
[10]  
2-8