Simultaneous determination of uric acid and ascorbic acid at the film of chitosan incorporating cetylpyridine bromide modified glassy carbon electrode

被引:22
|
作者
Cao, Xiaomei [1 ]
Xu, Yanhong [1 ]
Luo, Liqiang [1 ]
Ding, Yaping [1 ]
Zhang, Ying [1 ]
机构
[1] Shanghai Univ, Dept Chem, Shanghai 200444, Peoples R China
基金
中国国家自然科学基金;
关键词
Cetylpyridine bromide; Chitosan; Simultaneous determination; Ascorbic acid; Uric acid; ELECTROCHEMICAL DETERMINATION; VOLTAMMETRIC DETECTION; SELECTIVE DETECTION; DOPAMINE; FABRICATION; BIOSENSOR;
D O I
10.1007/s10008-009-0861-y
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A glassy carbon electrode (GCE) modified with the film composed of chitosan incorporating cetylpyridine bromide is constructed and used to determine uric acid (UA) and ascorbic acid (AA) by differential pulse voltammetry (DPV). This modified electrode shows efficient electrocatalytic activity and fairly selective separation for oxidation of AA and UA in mixture solution. UA is catalyzed by this modified electrode in phosphate buffer solution (pH 4.0) with a decrease of 80 mV, while AA is catalyzed with a decrease of 200 mV in overpotential compared to GCE, and the peak separation of oxidation between AA and UA is 260 mV, which is large enough to allow the determination of one in presence of the other. Under the optimum conditions, the anodic peak currents (I (pa)) of DPV are proportional to the concentration of UA in the range of 2.0 x 10(-6) to 6.0 x 10(-4) M, with the detection limit of 5.0 x 10(-7) M at a signal-to-noise ratio of 3 (S/N = 3) and to that of AA in the range of 4.0 x 10(-6) to 1.0 x 10(-3) M, with the detection limit of 8.0 x 10(-7) M (S/N = 3).
引用
收藏
页码:829 / 834
页数:6
相关论文
共 50 条
  • [21] Simultaneous determination of dopamine, uric acid and ascorbic acid using a glassy carbon electrode modified with reduced graphene oxide
    Wang, Huiwen
    Ren, Fangfang
    Wang, Caiqin
    Yang, Beibei
    Bin, Duan
    Zhang, Ke
    Du, Yukou
    RSC ADVANCES, 2014, 4 (51) : 26895 - 26901
  • [22] Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid with Chitosan-Graphene Modified Electrode
    Han, Dongxue
    Han, Tingting
    Shan, Changsheng
    Ivaska, Ari
    Niu, Li
    ELECTROANALYSIS, 2010, 22 (17-18) : 2001 - 2008
  • [23] A new sensor based on glassy carbon electrode modified with nanocomposite for simultaneous determination of acetaminophen, ascorbic acid and uric acid
    Afrasiabi, Mohammad
    Kianipour, Shokat
    Babaei, Ali
    Nasimi, Ali Asghar
    Shabanian, Meisam
    JOURNAL OF SAUDI CHEMICAL SOCIETY, 2016, 20 : S480 - S487
  • [24] Simultaneous determination of uric acid, dopamine and ascorbic acid based on poly(bromocresol green) modified glassy carbon electrode
    Ouyang, Xiaoqian
    Luo, Liqiang
    Ding, Yaping
    Liu, Bingdi
    Xu, Duo
    Huang, Anquan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 748 : 1 - 7
  • [25] Simultaneous voltammetric measurement of ascorbic acid, epinephrine and uric acid at a glassy carbon electrode modified with caffeic acid
    Ren, W
    Luo, HQ
    Li, NB
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (07): : 1086 - 1092
  • [26] Simultaneous determination of dopamine, uric acid and ascorbic acid at an ultrathin film modified gold electrode
    Gao, ZQ
    Huang, H
    CHEMICAL COMMUNICATIONS, 1998, (19) : 2107 - 2108
  • [27] Simultaneous determination of ascorbic acid, dopamine and uric acid using poly(4-aminobutyric acid) modified glassy carbon electrode
    Zheng, Xinyu
    Zhou, Xuechou
    Ji, Xiaoyan
    Lin, Ruiyu
    Lin, Wenxiong
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 359 - 365
  • [28] Simultaneous electrochemical determination of uric acid, dopamine, and ascorbic acid at single-walled carbon nanohorn modified glassy carbon electrode
    Zhu, Shuyun
    Li, Haijuan
    Niu, Wenxin
    Xu, Guobao
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (04): : 940 - 943
  • [29] A selective sensor based on a glassy carbon electrode modified with carbon nanotubes and ruthenium oxide/hexacyanoferrate film for simultaneous determination of ascorbic acid, epinephrine and uric acid
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Baghayeri, Mehdi
    ANALYTICAL METHODS, 2011, 3 (10) : 2367 - 2373
  • [30] Carbon-nanotube-modified glassy carbon electrode for simultaneous determination of dopamine, ascorbic acid and uric acid: The effect of functional groups
    Bi, Huaqing
    Li, Yanhui
    Liu, Shufeng
    Guo, Peizhi
    Wei, Zhongbin
    Lv, Chunxiao
    Zhang, Jizhen
    Zhao, X. S.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 1132 - 1140