Simultaneous determination of uric acid and ascorbic acid at the film of chitosan incorporating cetylpyridine bromide modified glassy carbon electrode

被引:22
作者
Cao, Xiaomei [1 ]
Xu, Yanhong [1 ]
Luo, Liqiang [1 ]
Ding, Yaping [1 ]
Zhang, Ying [1 ]
机构
[1] Shanghai Univ, Dept Chem, Shanghai 200444, Peoples R China
基金
中国国家自然科学基金;
关键词
Cetylpyridine bromide; Chitosan; Simultaneous determination; Ascorbic acid; Uric acid; ELECTROCHEMICAL DETERMINATION; VOLTAMMETRIC DETECTION; SELECTIVE DETECTION; DOPAMINE; FABRICATION; BIOSENSOR;
D O I
10.1007/s10008-009-0861-y
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A glassy carbon electrode (GCE) modified with the film composed of chitosan incorporating cetylpyridine bromide is constructed and used to determine uric acid (UA) and ascorbic acid (AA) by differential pulse voltammetry (DPV). This modified electrode shows efficient electrocatalytic activity and fairly selective separation for oxidation of AA and UA in mixture solution. UA is catalyzed by this modified electrode in phosphate buffer solution (pH 4.0) with a decrease of 80 mV, while AA is catalyzed with a decrease of 200 mV in overpotential compared to GCE, and the peak separation of oxidation between AA and UA is 260 mV, which is large enough to allow the determination of one in presence of the other. Under the optimum conditions, the anodic peak currents (I (pa)) of DPV are proportional to the concentration of UA in the range of 2.0 x 10(-6) to 6.0 x 10(-4) M, with the detection limit of 5.0 x 10(-7) M at a signal-to-noise ratio of 3 (S/N = 3) and to that of AA in the range of 4.0 x 10(-6) to 1.0 x 10(-3) M, with the detection limit of 8.0 x 10(-7) M (S/N = 3).
引用
收藏
页码:829 / 834
页数:6
相关论文
共 29 条
[1]   Ascorbic acid: much more than just an antioxidant [J].
Arrigoni, O ;
De Tullio, MC .
BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2002, 1569 (1-3) :1-9
[2]   AN IMPROVED VOLTAMMETRIC METHOD FOR THE DETERMINATION OF TRACE AMOUNTS OF URIC-ACID WITH ELECTROCHEMICALLY PRETREATED CARBON-PASTE ELECTRODES [J].
CAI, XH ;
KALCHER, K ;
NEUHOLD, C ;
OGOREVC, B .
TALANTA, 1994, 41 (03) :407-413
[3]   Electrochemical methods for simultaneous determination of dopamine and ascorbic acid using cetylpyridine bromide/chitosan composite film-modified glassy carbon electrode [J].
Cao, Xiaomei ;
Luo, Liqiang ;
Ding, Yaping ;
Zou, Xuelian ;
Bian, Ruixiang .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (02) :941-946
[4]   Simultaneous detection of ascorbic acid and uric acid using a fluorosurfactant-modified platinum electrode [J].
Chen, Zuofeng ;
Zu, Yanbing .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 603 (02) :281-286
[5]  
DUTT V V S E, 1974, Analytical Chemistry, V46, P1777, DOI 10.1021/ac60348a041
[6]   NOVEL, REAGENTLESS, AMPEROMETRIC BIOSENSOR FOR URIC-ACID BASED ON A CHEMICALLY-MODIFIED SCREEN-PRINTED CARBON ELECTRODE COATED WITH CELLULOSE-ACETATE AND URICASE [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1994, 119 (05) :833-840
[7]  
HAN X, 2007, CHIN J ANAL LAB, V26, P30
[8]  
Harper H.A., 1977, Review of Physiological Chemistry, V16th
[9]   A quercetin-modified biosensor for amperometric determination of uric acid in the presence of ascorbic acid [J].
He, Jian-Bo ;
Jin, Guan-Ping ;
Chen, Qun-Zhi ;
Wang, Yan .
ANALYTICA CHIMICA ACTA, 2007, 585 (02) :337-343
[10]   Simultaneous determination of uric acid and ascorbic acid using edge plane pyrolytic graphite electrodes [J].
Kachoosangi, RT ;
Banks, CE ;
Compton, RG .
ELECTROANALYSIS, 2006, 18 (08) :741-747