A novel microelectrode array combining screen-printing and femtosecond laser ablation technologies: Development, characterization and application to cadmium detection
被引:32
作者:
Cugnet, Cyril
论文数: 0引用数: 0
h-index: 0
机构:
Univ Pau & Pays Adour, CNRS, Lab Chim Analyt & Bioinorgan, UMR IPREM 5254, F-64053 Pau 9, FranceUniv Pau & Pays Adour, CNRS, Lab Chim Analyt & Bioinorgan, UMR IPREM 5254, F-64053 Pau 9, France
Cugnet, Cyril
[1
]
Zaouak, Olivier
论文数: 0引用数: 0
h-index: 0
机构:
Univ Pau & Pays Adour, CNRS, Lab Chim Analyt & Bioinorgan, UMR IPREM 5254, F-64053 Pau 9, FranceUniv Pau & Pays Adour, CNRS, Lab Chim Analyt & Bioinorgan, UMR IPREM 5254, F-64053 Pau 9, France
Zaouak, Olivier
[1
]
Rene, Alice
论文数: 0引用数: 0
h-index: 0
机构:
Univ Pau & Pays Adour, CNRS, Lab Chim Analyt & Bioinorgan, UMR IPREM 5254, F-64053 Pau 9, FranceUniv Pau & Pays Adour, CNRS, Lab Chim Analyt & Bioinorgan, UMR IPREM 5254, F-64053 Pau 9, France
Rene, Alice
[1
]
Pecheyran, Christophe
论文数: 0引用数: 0
h-index: 0
机构:
Univ Pau & Pays Adour, CNRS, Lab Chim Analyt & Bioinorgan, UMR IPREM 5254, F-64053 Pau 9, FranceUniv Pau & Pays Adour, CNRS, Lab Chim Analyt & Bioinorgan, UMR IPREM 5254, F-64053 Pau 9, France
Pecheyran, Christophe
[1
]
Potin-Gautier, Martine
论文数: 0引用数: 0
h-index: 0
机构:
Univ Pau & Pays Adour, CNRS, Lab Chim Analyt & Bioinorgan, UMR IPREM 5254, F-64053 Pau 9, FranceUniv Pau & Pays Adour, CNRS, Lab Chim Analyt & Bioinorgan, UMR IPREM 5254, F-64053 Pau 9, France
Potin-Gautier, Martine
[1
]
Authier, Laurent
论文数: 0引用数: 0
h-index: 0
机构:
Univ Pau & Pays Adour, CNRS, Lab Chim Analyt & Bioinorgan, UMR IPREM 5254, F-64053 Pau 9, FranceUniv Pau & Pays Adour, CNRS, Lab Chim Analyt & Bioinorgan, UMR IPREM 5254, F-64053 Pau 9, France
Authier, Laurent
[1
]
机构:
[1] Univ Pau & Pays Adour, CNRS, Lab Chim Analyt & Bioinorgan, UMR IPREM 5254, F-64053 Pau 9, France
来源:
SENSORS AND ACTUATORS B-CHEMICAL
|
2009年
/
143卷
/
01期
The elaboration of a new kind of microelectrode array based on femtosecond laser ablation and screen-printing process was reported. The electrochemical behavior of this sensor, constituted by a square array of 8 x 8 screen-printed carbon-based microelectrodes, was characterized by cyclic voltammetry (CV) and compared with macroelectrodes. With an interelectrode distance-to-electrode diameter ratio of 21, this screen-printed microelectrode array (SP mu EA) has shown a superior diffusion behavior and a greater mass-transport. The analytical performances of this mercury modified SP mu EA were evaluated for cadmium detection. Promising results were obtained with synthetic cadmium solutions in acetate buffer by square-wave anodic stripping voltammetry (SWASV) technique with a detection limit of 1.3 mu g L-1 and were confirmed with application to a river sample. (C) 2009 Elsevier B.V. All rights reserved.