Comparison at the O'Brien filter test and the PFA-100 platelet analyzer in the laboratory diagnosis of von Willebrand's disease

被引:35
|
作者
Schlammadinger, A
Kerenyi, A
Muszbek, L
Boda, Z
机构
[1] Univ Debrecen, Dept Med 2, H-4012 Debrecen, Hungary
[2] Univ Debrecen, Dept Clin Biochem & Mol Pathol, H-4012 Debrecen, Hungary
关键词
von Wildebrand's disease; high shear induced platelet activation; O'Brien filter test; PFA-100; system;
D O I
10.1055/s-0037-1613973
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Von Willebrand's disease (vWD) is the most common congenital haemorrhagic diathesis, characterized by the quantitative or qualitative disorder of von Willebrand factor (vWF). A number of methods have been used for the diagnosis of the disease, and the bleeding time determination is widely accepted as a screening test in spite of its low sensitivity. Our aim was to evaluate and compare the performance of two high shear systems (the O'Brien filter test and the PFA-100 device) in the screening and diagnosis of vWD. Thirty patients (n=13 type 1 with mild symptoms, n = 9 type 1 with severe symptoms, n = 2 type 2A, n =3 type 2B and n = 3 type 3 vWD) and twenty controls were investigated. In mild vWD the platelet retention in the second phase of the tilter test with citrated blood showed the highest sensitivity (91.6%). The sensitivity of the PFA-100 method with collagen-epinephrine cartridges in this group was 76.9%, while the bleeding time was prolonged only in 15.4% of the cases. In severe type 1, in type 2A and type 3 all functional tests reflected the bleeding tendency of the patients. In type 2B disease the bleeding time was prolonged only when the patient was thrombocytopenic. but both high shear systems revealed the disease independently of the presence of thrombocytopenia. The overall sensitivity of the bleeding time determination was 50% compared to the 80-90% sensitivity of the O'Brien Filter test and the PFA-100 system. The sensitivity values of the filter test and the PFA-100 device with collagen-epinephrine cartridges were In the same range, but the collagen-ADP cartridges showed a lower (65.5%) sensitivity, though the results were specific and had high positive predictive value. We conclude that both high shear systems are suitable for the screening of; vWD, and that they are superior to the traditional bleeding time determination In case of mild disease or type 2B vWD.
引用
收藏
页码:88 / 92
页数:5
相关论文
共 21 条
  • [1] The Platelet Function Analyzer (PFA-100) may not be suitable for monitoring the therapeutic efficiency of von Willebrand concentrate in type III von Willebrand disease
    Meskal, A
    Vertessen, F
    Van der Planken, M
    Berneman, ZN
    ANNALS OF HEMATOLOGY, 1999, 78 (09) : 426 - 430
  • [2] The Platelet Function Analyzer (PFA-100) may not be suitable for monitoring the therapeutic efficiency of von Willebrand concentrate in type III von Willebrand disease
    A. Meskal
    F. Vertessen
    M. Van der Planken
    Z. N. Berneman
    Annals of Hematology, 1999, 78 : 426 - 430
  • [3] Comparison of PFA-100 testing and bleeding time for detecting platelet hypofunction and von Willebrand disease in clinical practice
    Posan, E
    McBane, RD
    Grill, DE
    Motsko, CL
    Nichols, WL
    THROMBOSIS AND HAEMOSTASIS, 2003, 90 (03) : 483 - 490
  • [4] Rational use of the PFA-100 device for screening of platelet function disorders and von Willebrand disease
    Buyukasik, Y
    Karakus, S
    Goker, H
    Haznedaroglu, IC
    Ozatli, D
    Sayinalp, N
    Ozcebe, OI
    Dundar, SV
    Kirazli, S
    BLOOD COAGULATION & FIBRINOLYSIS, 2002, 13 (04) : 349 - 353
  • [5] The utility of the PFA-100 in the identification of von Willebrand disease: A concise review
    Favaloro, Emmanuel J.
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2006, 32 (05) : 537 - 545
  • [6] Laboratory monitoring of therapy in von Willebrand disease: Efficacy of the PFA-100 and von Willebrand factor: Collagen-binding activity as coupled strategies
    Favaloro, Emmanuel J.
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2006, 32 (06) : 566 - 576
  • [7] Evaluation of platelet function in dogs with cardiac disease using the PFA-100 platelet function analyzer
    Clancey, Noel
    Burton, Shelley
    Horney, Barbara
    MacKenzie, Allan
    Nicastro, Andrea
    Cote, Etienne
    VETERINARY CLINICAL PATHOLOGY, 2009, 38 (03) : 299 - 305
  • [8] The Prevalence of von Willebrand Disease and Significance of in Vitro Bleeding Time (PFA-100) in von Willebrand Disease Screening in the Izmir Region
    Sap, Fatih
    Kavakli, Tulay
    Kavakli, Kaan
    Dizdarer, Ceyhun
    TURKISH JOURNAL OF HEMATOLOGY, 2013, 30 (01) : 40 - 47
  • [9] Potential supplementary utility of combined PFA-100 and functional von Willebrand factor testing for the laboratory assessment of desmopressin and factor concentrate therapy in von Willebrand disease
    Favaloro, Emmanuel J.
    Thom, Jim
    Patterson, David
    Just, Sarah
    Baccala, Maria
    Dixon, Tracy
    Meiring, Muriel
    Koutts, Jerry
    Rowell, John
    Baker, Ross
    BLOOD COAGULATION & FIBRINOLYSIS, 2009, 20 (06) : 475 - 483
  • [10] Utility of the platelet function analyser (PFA-100/200) for exclusion or detection of von Willebrand disease: A study 22 years in the making
    Favaloro, Emmanuel J.
    THROMBOSIS RESEARCH, 2020, 188 : 17 - 24