Positional Reproducibility and Effects of a Rectal Balloon in Prostate Cancer Radiotherapy

被引:13
作者
Cho, Jae Ho [1 ]
Lee, Chang-Geol [1 ]
Kang, Dae Ryong [2 ]
Kim, Jooho [1 ]
Lee, Sangkyu [1 ]
Suh, Chang-Ok [1 ]
Seong, Jinsil [1 ]
Suh, Yang Gun [1 ]
Lee, Ikjae [1 ]
Kim, Gwi Eon [1 ]
机构
[1] Yonsei Univ Hlth Syst, Dept Radiat Oncol, Yonsei Canc Ctr, Seoul 120752, South Korea
[2] Yonsei Univ Hlth Syst, Div Clin Data Management Syst & Bioinformat, Clin Trials Ctr, Seoul 120752, South Korea
关键词
Rectal Balloon; Prostatic Neoplasms; Radiotherapy; Intensity-Modulated; 3D Conformal Radiotherapy; Acute Toxicity; CONFORMAL RADIATION-THERAPY; INTENSITY-MODULATED RADIOTHERAPY; ENDORECTAL BALLOON; ACUTE TOXICITY; DOSE-ESCALATION; IMMOBILIZATION DEVICE; RADIOPAQUE MARKERS; 70; GY; LOCALIZATION; IMRT;
D O I
10.3346/jkms.2009.24.5.894
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Despite the increasing use of the rectal balloon in prostate cancer radiotherapy, many issues still remain to be verified objectively including its positional reproducibility and relevance to treatment morbidity. We have developed a custom rectal balloon that has a scale indicating the depth of insertion and dilates symmetrically ensuring positional reproducibility. Fifty patients with prostate cancer treated by definitive 3D-conformal radiotherapy (3D-CRT) or intensity-modulated radiotherapy (IMRT) with rectal balloon were analyzed. Each of first five patients undergone computed tomography (CT) three times with a rectal balloon. The positional reproducibility was tested by Intraclass Correlation Coefficient (ICC) from the CT-to-CT fusion images. Planning variables and clinical acute toxicities were compared between when or not applying balloon. An ICC of greater than 0.9 in all directions revealed an excellent reproducibility of the balloon. Rectal balloon improved considerably the mean dose and V-45Gy-V-65Gy in plan comparison, and especially in 3D-CRT the rectal volume exposed to more than 60 Gy dropped from 41.3% to 19.5%. Clinically, the balloon lowered acute toxicity, which was lowest when both the balloon and IMRT were applied simultaneously. The rectal balloon carries excellent reproducibility and reduces acute toxicity in 3D-CRT and IMRT for prostate cancer.
引用
收藏
页码:894 / 903
页数:10
相关论文
共 37 条
  • [1] Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility
    Balter, JM
    Lam, KL
    Sandler, HM
    Littles, JF
    Bree, RL
    TenHaken, RK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05): : 1281 - 1286
  • [2] Tolerance of endorectal balloon in 396 patients treated with intensity-modulated radiation therapy (IMRT) for prostate cancer
    Bastasch, MD
    Teh, BS
    Mai, WY
    McGary, JE
    Grant, WH
    Butler, EB
    [J]. AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2006, 29 (01): : 8 - 11
  • [3] Fractionation and protraction for radiotherapy of prostate carcinoma
    Brenner, DJ
    Hall, EJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (05): : 1095 - 1101
  • [4] Ultra-high dose (86.4 Gy) IMRT for localized prostate cancer: Toxicity and biochemical outcomes
    Cahlon, Oren
    Zelefsky, Michael J.
    Shippy, Alison
    Chan, Heather
    Fuks, Zvi
    Yamada, Yoshiya
    Hunt, Margie
    Greenstein, Steven
    Amols, Howard
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (02): : 330 - 337
  • [5] On-line correction of beam portals in the treatment of prostate cancer using an endorectal balloon device
    Ciernik, IF
    Baumert, BG
    Egli, P
    Glanzmann, C
    Lütolf, UM
    [J]. RADIOTHERAPY AND ONCOLOGY, 2002, 65 (01) : 39 - 45
  • [6] Motion and shape change when using an endorectal balloon during prostate radiation therapy
    Court, Laurence E.
    D'Amico, Anthony V.
    Kadam, Dnyanesh
    Cormack, Robert
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 (02) : 184 - 189
  • [7] TOXICITY CRITERIA OF THE RADIATION-THERAPY ONCOLOGY GROUP (RTOG) AND THE EUROPEAN-ORGANIZATION-FOR-RESEARCH-AND-TREATMENT-OF-CANCER (EORTC)
    COX, JD
    STETZ, J
    PAJAK, TF
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (05): : 1341 - 1346
  • [8] The impact of geometric uncertainty on hypofractionated external beam radiation therapy of prostate cancer
    Craig, T
    Moiseenko, V
    Battista, J
    Van Dyk, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (03): : 833 - 842
  • [9] A prospective evaluation of rectal bleeding after dose-escalated three-dimensional conformal radiation therapy using an intrarectal balloon for prostate gland localization and immobilization
    D'Amico, AV
    Manola, J
    McMahon, E
    Loffredo, M
    Lopes, L
    Ching, J
    Albert, M
    Hurwitz, M
    Suh, WW
    Vivenzio, TA
    Beard, C
    [J]. UROLOGY, 2006, 67 (04) : 780 - 784
  • [10] Intensity-modulated radiotherapy as primary treatment for prostate cancer: Acute toxicity in 114 patients
    De Meerleer, G
    Vakaet, L
    Meersschout, S
    Villeirs, G
    Verbaeys, A
    Oosterlinck, W
    De Neve, W
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03): : 777 - 787