Cell separation by an aqueous two-phase system in a microfluidic device

被引:63
|
作者
Tsukamoto, Masatoshi [2 ]
Taira, Shu [2 ]
Yamamura, Shohei [3 ]
Morita, Yasutaka [4 ]
Nagatani, Naoki [5 ]
Takamura, Yuzuru [2 ]
Tamiya, Eiichi [1 ]
机构
[1] Grad Sch Engn, Dept Appl Phys, Suita, Osaka 5650871, Japan
[2] Japan Adv Inst Sci & Technol JAIST, Sch Mat Sci, Nomi, Ishikawa 9231211, Japan
[3] Adv Ind Sci & Technol, Hlth Technol Res Ctr, Shiko Ku, Kagawa 7610395, Japan
[4] Kinki Univ, Fac Human Oriented Sci & Engn, Fukuoka 8208555, Japan
[5] Okayama Univ Sci, Fac Engn, Dept Biotechnol & Appl Chem, Okayama 7000005, Japan
关键词
MATERNAL BLOOD; PARTITION; MICROCHIP; DIAGNOSIS; FORCE;
D O I
10.1039/b909597g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We generated an aqueous two-phase laminar flow in a microfluidic chip and used the system to isolate leukocyte and erythrocyte cells from whole blood cells. The microfluidic system reduced the effect of gravity in the aqueous two-phase system (ATPS). Poly(ethylene glycol) (PEG) and dextran (Dex) solutions were used as the two phases, and the independent flow rates of the solutions were both 2 mu L/min. When hydrophobic and hydrophilic polystyrene beads were introduced into the microfluidic device, the hydrophilic beads moved to the Dex layer and the hydrophobic beads to the interface between the two phases. In the case of living cells, Jurkat cells and erythrocytes moved more efficiently to the PEG and Dex layers, respectively, than they move in a conventional ATPS. When whole blood cells were inserted into the microfluidic chip, leukocytes could be separated from erythrocytes because erythrocytes moved to the Dex layer while leukocytes remained outside of this layer in the microfluidic system. The reported microfluidic chip for the whole blood cell separation can effectively be integrated into a Micro Total Analysis System designed for cell-based clinical, forensic, and environmental analyses.
引用
收藏
页码:1994 / 1998
页数:5
相关论文
共 50 条
  • [31] Extraction of Betanin Using Aqueous Two-Phase Systems
    Ebrahimi, Tahereh
    Shahriari, Shahla
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 2016, 89 (05) : 565 - 572
  • [32] Purification of bacterial inulinase in aqueous two-phase systems
    Temkov, Mishela
    Strinska, Hristina
    Dobrev, Georgi
    Velickova, Elena
    Muresan, Vlad
    Krastanov, Albert
    ENGINEERING IN LIFE SCIENCES, 2018, 18 (11): : 840 - 850
  • [33] Optimization of aqueous two-phase systems for the production of 6-aminopenicillanic acid in integrated microfluidic reactors-separators
    Vobecka, Lucie
    Romanov, Alexandr
    Slouka, Zdenek
    Hasal, Pavel
    Pribyl, Michal
    NEW BIOTECHNOLOGY, 2018, 47 : 73 - 79
  • [34] Affinity separation by protein conjugated IgG in aqueous two-phase systems using horseradish peroxidase as a ligand carrier
    Park, Hye-Mee
    Lee, Sang-Woo
    Chang, Woo-Jin
    Koo, Yoon-Mo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2): : 108 - 112
  • [35] Synthesis of two pH-responsive copolymers in pilot scale and its application in aqueous two-phase system
    Yang, Ting
    Pan, Hongxia
    He, Juan
    Gai, Zhiliang
    Cao, Xuejun
    PROCESS BIOCHEMISTRY, 2019, 79 : 185 - 194
  • [36] Application of an Aqueous Two-Phase Systems High-Throughput Screening Method to Evaluate mAb HCP Separation
    Oelmeier, Stefan A.
    Dismer, Florian
    Hubbuch, Juergen
    BIOTECHNOLOGY AND BIOENGINEERING, 2011, 108 (01) : 69 - 81
  • [37] Preparation of Janus Droplets and Hydrogels with Controllable Morphologies by an Aqueous Two-Phase System on the Superamphiphobic Surface
    Cheng, Quanyong
    Chen, Jingyi
    Wan, Chuchu
    Song, Yuhang
    Huang, Caili
    ACS APPLIED MATERIALS & INTERFACES, 2022, : 50434 - 50443
  • [38] Impact of aqueous two-phase system design parameters upon the in situ refolding and recovery of invertase
    Sanchez-Trasvina, Calef
    Gonzalez-Valdez, Jose
    Mayolo-Deloisa, Karla
    Rito-Palomares, Marco
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2015, 90 (10) : 1765 - 1772
  • [39] Effect of NaCl additive on properties of aqueous PEG-sodium sulfate two-phase system
    Ferreira, Luisa A.
    Parpot, Pier
    Teixeira, Jose A.
    Mikheeva, Larissa M.
    Zaslavsky, Boris Y.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1220 : 14 - 20
  • [40] Aqueous two-phase system to isolate extracellular vesicles from urine for prostate cancer diagnosis
    Shin, Hyunwoo
    Park, Yong Hyun
    Kim, Yong-Goo
    Lee, Ji Youl
    Park, Jaesung
    PLOS ONE, 2018, 13 (03):