Cell separation by an aqueous two-phase system in a microfluidic device

被引:63
|
作者
Tsukamoto, Masatoshi [2 ]
Taira, Shu [2 ]
Yamamura, Shohei [3 ]
Morita, Yasutaka [4 ]
Nagatani, Naoki [5 ]
Takamura, Yuzuru [2 ]
Tamiya, Eiichi [1 ]
机构
[1] Grad Sch Engn, Dept Appl Phys, Suita, Osaka 5650871, Japan
[2] Japan Adv Inst Sci & Technol JAIST, Sch Mat Sci, Nomi, Ishikawa 9231211, Japan
[3] Adv Ind Sci & Technol, Hlth Technol Res Ctr, Shiko Ku, Kagawa 7610395, Japan
[4] Kinki Univ, Fac Human Oriented Sci & Engn, Fukuoka 8208555, Japan
[5] Okayama Univ Sci, Fac Engn, Dept Biotechnol & Appl Chem, Okayama 7000005, Japan
关键词
MATERNAL BLOOD; PARTITION; MICROCHIP; DIAGNOSIS; FORCE;
D O I
10.1039/b909597g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We generated an aqueous two-phase laminar flow in a microfluidic chip and used the system to isolate leukocyte and erythrocyte cells from whole blood cells. The microfluidic system reduced the effect of gravity in the aqueous two-phase system (ATPS). Poly(ethylene glycol) (PEG) and dextran (Dex) solutions were used as the two phases, and the independent flow rates of the solutions were both 2 mu L/min. When hydrophobic and hydrophilic polystyrene beads were introduced into the microfluidic device, the hydrophilic beads moved to the Dex layer and the hydrophobic beads to the interface between the two phases. In the case of living cells, Jurkat cells and erythrocytes moved more efficiently to the PEG and Dex layers, respectively, than they move in a conventional ATPS. When whole blood cells were inserted into the microfluidic chip, leukocytes could be separated from erythrocytes because erythrocytes moved to the Dex layer while leukocytes remained outside of this layer in the microfluidic system. The reported microfluidic chip for the whole blood cell separation can effectively be integrated into a Micro Total Analysis System designed for cell-based clinical, forensic, and environmental analyses.
引用
收藏
页码:1994 / 1998
页数:5
相关论文
共 50 条
  • [31] Review of recent applications and modifications of aqueous two-phase system for the separation of biomolecules
    Segaran, A.
    Chua, L. S.
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2024, 276
  • [32] Aqueous Two-Phase System (ATPS)-Based Polymersomes for Particle Isolation and Separation
    Seo, Hanjin
    Nam, Changwoo
    Kim, Eunseo
    Son, Juhyun
    Lee, Hyomin
    ACS APPLIED MATERIALS & INTERFACES, 2020, 12 (49) : 55467 - 55475
  • [33] Separation of β-lactoglobulin from cheese whey using and aqueous two-phase system
    Coimbra, JSR
    Thoemmes, J
    Kula, MR
    Silva, LHM
    Meirelles, AJA
    ARQUIVOS DE BIOLOGIA E TECNOLOGIA, 1997, 40 (01): : 189 - 196
  • [34] Continuous-Flow Fractionation of Animal Cells in Microfluidic Device Using Aqueous Two-Phase Extraction
    Ki-Hwan Nam
    Woo-Jin Chang
    Hyejin Hong
    Sang-Min Lim
    Dong-Il Kim
    Yoon-Mo Koo
    Biomedical Microdevices, 2005, 7 : 189 - 195
  • [35] Aqueous two-phase electrophoresis for separation of amino acids
    Zhai, SL
    Luo, GS
    Liu, JG
    SEPARATION AND PURIFICATION TECHNOLOGY, 2001, 21 (03) : 197 - 203
  • [36] Aqueous two-phase systems for protein separation: A perspective
    Asenjo, Juan A.
    Andrews, Barbara A.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (49) : 8826 - 8835
  • [37] Aqueous Micellar Two-Phase Systems for Protein Separation
    Hirofumi Tani
    Tamio Kamidate
    Hiroto Watanabe
    Analytical Sciences, 1998, 14 : 875 - 888
  • [38] Tobacco protein separation by aqueous two-phase extraction
    Balasubramaniam, D
    Wilkinson, C
    Van Cott, K
    Zhang, CM
    JOURNAL OF CHROMATOGRAPHY A, 2003, 989 (01) : 119 - 129
  • [39] Aqueous micellar two-phase systems for protein separation
    Tani, H
    Kamidate, T
    Watanabe, H
    ANALYTICAL SCIENCES, 1998, 14 (05) : 875 - 888
  • [40] Separation Behavior of Penicillin in Aqueous Two-Phase Flotation
    Bi Peng-Yu
    Chang Lin
    Dong Hui-Ru
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (03) : 425 - 428