The Relationship Between Polyethylene Wear and Periprosthetic Osteolysis in Total Hip Arthroplasty at 12 Years in a Randomized Controlled Trial Cohort

被引:44
|
作者
Broomfield, John A. J. [1 ]
Malak, Tamer T. [1 ]
Thomas, Geraint E. R. [1 ]
Palmer, Antony J. R. [1 ]
Taylor, Adrian [1 ]
Glyn-Jones, Sion [1 ]
机构
[1] Univ Oxford, Botnar Res Ctr, Nuffield Dept Orthopaed Rheumatol & Musculoskelet, Oxford OX3 7LD, England
来源
JOURNAL OF ARTHROPLASTY | 2017年 / 32卷 / 04期
关键词
primary total hip arthroplasty; polyethylene wear; periprosthetic osteolysis; highly cross-linked polyethylene; Computed Tomography; RSA; CROSS-LINKED POLYETHYLENE; MOLECULAR-WEIGHT POLYETHYLENE; TOTAL JOINT REPLACEMENTS; COMPUTED-TOMOGRAPHY; PELVIC OSTEOLYSIS; RADIOSTEREOMETRIC ANALYSIS; ACETABULAR OSTEOLYSIS; DOUBLE-BLIND; PARTICLES; FLUID;
D O I
10.1016/j.arth.2016.10.037
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Polyethylene acetabular components are common in hip arthroplasty. Highly cross-linked polyethylene (HXLPE) has lower wear than ultra-high molecular weight polyethylene (UHMWPE). Evidence suggests that wear particles induce inflammation causing periprosthetic osteolysis contributing to implant loosening with wear rates of 0.05 mm/y were considered safe. We aimed to compare incidence and volume of periacetabular osteolysis between HXLPE and UHMWPE using computed tomography. Methods: Initially, 54 hips in 53 patients were randomized to HXLPE or UHMWPE acetabular liner. At 10 years, 39 hips in 38 patients remained for the radiostereometric analysis' demonstrating significantly lower wear in the HXLPE group. At 12 years, 14 hips in 13 patients were lost to follow-up leaving 25 hips for computed tomography assessment. Images were reconstructed to detect osteolysis and where identified, areas were segmented and volumized. Results: Osteolysis was observed in 8 patients, 7 from the UHMWPE group and only 1 from the HXLPE group (Fisher exact, P = .042). There was no correlation between the amount of polyethylene wear and osteolysis volume; however, the radiostereometric analysis-measured wear rate in patients with osteolysis from both groups was significantly higher than overall average wear rate. Conclusion: This data demonstrates lower incidence of periacetabular osteolysis in the HXLPE group of a small cohort. Although numbers are too low to estimate causation, in the context of lower wear in the HXLPE group, this finding supports the hypothesis that HXLPE may not elevate osteolysis risk, and hence does not suggest that HXLPE wear particles are more biologically active than those generated by earlier generations of polyethylene. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1186 / 1191
页数:6
相关论文
共 50 条
  • [21] Conventional Polyethylene in Total Hip Arthroplasty in Young Patients: Survivorship, Wear Analysis, and Clinical Outcomes Between 15 and 20 Years
    Stambough, Jeffrey B.
    Rames, Richard D.
    Pashos, Gail E.
    Maloney, William J.
    Martell, John M.
    Clohisy, John C.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (12): : 3712 - 3718
  • [22] Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial
    Hugo C van der Veen
    Inge van den Akker-Scheek
    Sjoerd K Bulstra
    Jos JAM van Raay
    BMC Musculoskeletal Disorders, 13
  • [23] Highly cross-linked versus conventional polyethylene inserts in total hip arthroplasty, a five-year Roentgen stereophotogrammetric analysis randomised controlled trial
    van Loon, Justin
    Hoornenborg, Daniel
    Sierevelt, Inger
    Opdam, Kim T. M.
    Kerkhoffs, Gino M. M. J.
    Haverkamp, Daniel
    WORLD JOURNAL OF ORTHOPEDICS, 2020, 11 (10): : 442 - 452
  • [24] Large Femoral Heads Decrease the Incidence of Dislocation After Total Hip Arthroplasty A Randomized Controlled Trial
    Howie, Donald W.
    Holubowycz, Oksana T.
    Middleton, Robert
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (12): : 1095 - 1102
  • [25] Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial
    Wierd P Zijlstra
    Nanne Bos
    Jos JAM van Raaij
    BMC Musculoskeletal Disorders, 9
  • [26] Complete acetabular cup revision versus isolated liner exchange for polyethylene wear and osteolysis without loosening in cementless total hip arthroplasty
    Koh, Kyoung Hwan
    Moon, Young-Wan
    Lim, Seung-Jae
    Lee, Hyun Il
    Shim, Jae Woo
    Park, Youn-Soo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (11) : 1591 - 1600
  • [27] Effect of polyethylene wear on osteolysis in cementless primary total hip arthroplasty - Minimal 5-year follow-up study
    Han, CD
    Choe, WS
    Yoo, JH
    JOURNAL OF ARTHROPLASTY, 1999, 14 (06): : 714 - 723
  • [28] Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial
    Scemama, Caroline
    Anract, Philippe
    Dumaine, Valerie
    Babinet, Antoine
    Courpied, Jean Pierre
    Hamadouche, Moussa
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (06) : 1113 - 1118
  • [29] Denosumab Prevents Early Periprosthetic Bone Loss After Uncemented Total Hip Arthroplasty: Results from a Randomized Placebo-Controlled Clinical Trial
    Nystrom, Andreas
    Kiritopoulos, Demostenis
    Ullmark, Gosta
    Sorensen, Jens
    Petren-Mallmin, Marianne
    Milbrink, Jan
    Hailer, Nils P.
    Mallmin, Hans
    JOURNAL OF BONE AND MINERAL RESEARCH, 2020, 35 (02) : 239 - 247
  • [30] Pain After Preoperative Ultrasound Guided Hip Injections for Total Hip Arthroplasty: A Pilot Randomized Controlled Trial
    Holbert, S. Elliott
    Fowler, Brook
    West, Michaline
    Morris, Jennifer
    Turcotte, Justin
    King, Paul
    SURGICAL INNOVATION, 2023, 30 (02) : 176 - 183