The Relationship Between Polyethylene Wear and Periprosthetic Osteolysis in Total Hip Arthroplasty at 12 Years in a Randomized Controlled Trial Cohort

被引:44
|
作者
Broomfield, John A. J. [1 ]
Malak, Tamer T. [1 ]
Thomas, Geraint E. R. [1 ]
Palmer, Antony J. R. [1 ]
Taylor, Adrian [1 ]
Glyn-Jones, Sion [1 ]
机构
[1] Univ Oxford, Botnar Res Ctr, Nuffield Dept Orthopaed Rheumatol & Musculoskelet, Oxford OX3 7LD, England
来源
JOURNAL OF ARTHROPLASTY | 2017年 / 32卷 / 04期
关键词
primary total hip arthroplasty; polyethylene wear; periprosthetic osteolysis; highly cross-linked polyethylene; Computed Tomography; RSA; CROSS-LINKED POLYETHYLENE; MOLECULAR-WEIGHT POLYETHYLENE; TOTAL JOINT REPLACEMENTS; COMPUTED-TOMOGRAPHY; PELVIC OSTEOLYSIS; RADIOSTEREOMETRIC ANALYSIS; ACETABULAR OSTEOLYSIS; DOUBLE-BLIND; PARTICLES; FLUID;
D O I
10.1016/j.arth.2016.10.037
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Polyethylene acetabular components are common in hip arthroplasty. Highly cross-linked polyethylene (HXLPE) has lower wear than ultra-high molecular weight polyethylene (UHMWPE). Evidence suggests that wear particles induce inflammation causing periprosthetic osteolysis contributing to implant loosening with wear rates of 0.05 mm/y were considered safe. We aimed to compare incidence and volume of periacetabular osteolysis between HXLPE and UHMWPE using computed tomography. Methods: Initially, 54 hips in 53 patients were randomized to HXLPE or UHMWPE acetabular liner. At 10 years, 39 hips in 38 patients remained for the radiostereometric analysis' demonstrating significantly lower wear in the HXLPE group. At 12 years, 14 hips in 13 patients were lost to follow-up leaving 25 hips for computed tomography assessment. Images were reconstructed to detect osteolysis and where identified, areas were segmented and volumized. Results: Osteolysis was observed in 8 patients, 7 from the UHMWPE group and only 1 from the HXLPE group (Fisher exact, P = .042). There was no correlation between the amount of polyethylene wear and osteolysis volume; however, the radiostereometric analysis-measured wear rate in patients with osteolysis from both groups was significantly higher than overall average wear rate. Conclusion: This data demonstrates lower incidence of periacetabular osteolysis in the HXLPE group of a small cohort. Although numbers are too low to estimate causation, in the context of lower wear in the HXLPE group, this finding supports the hypothesis that HXLPE may not elevate osteolysis risk, and hence does not suggest that HXLPE wear particles are more biologically active than those generated by earlier generations of polyethylene. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1186 / 1191
页数:6
相关论文
共 50 条
  • [1] Wear Rate of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty A Randomized Controlled Trial
    McCalden, Richard W.
    MacDonald, Steven J.
    Rorabeck, Cecil H.
    Bourne, Robert B.
    Chess, David G.
    Charron, Kory D.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (04): : 773 - 782
  • [2] Catastrophic Periprosthetic Osteolysis in Total Hip Arthroplasty at 20 Years: A Case Report and Literature Review
    Xing, Dan
    Li, Rujun
    Li, Jiao Jiao
    Tao, Ke
    Lin, Jianhao
    Yan, Taiqiang
    Zhou, Diange
    ORTHOPAEDIC SURGERY, 2022, 14 (08) : 1918 - 1926
  • [3] Creep and Wear in Vitamin E-Infused Highly Cross-Linked Polyethylene Cups for Total Hip Arthroplasty A Prospective Randomized Controlled Trial
    Rochcongar, G.
    Buia, G.
    Bourroux, E.
    Dunet, J.
    Chapus, V.
    Hulet, C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (02): : 107 - 114
  • [4] Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty
    Jiri Gallo
    Vitezslav Havranek
    Jana Zapletalova
    International Orthopaedics, 2010, 34 : 19 - 26
  • [5] Highly Crosslinked Polyethylene Reduces Wear in Total Hip Arthroplasty at 5 Years
    Mutimer, Jonathan
    Devane, Peter A.
    Adams, Kathryn
    Horne, J. Geoffrey
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (12) : 3228 - 3233
  • [6] Early polyethylene wear and osteolysis in cementless total hip arthroplasty - The influence of femoral head size and polyethylene thickness
    Lee, PC
    Shih, CH
    Chen, WJ
    Tu, YK
    Tai, CL
    JOURNAL OF ARTHROPLASTY, 1999, 14 (08): : 976 - 981
  • [7] Comparison of wear rate and osteolysis between annealed and remelted highly cross-linked polyethylene in total hip arthroplasty. A case control study at 7 to 10 years follow-up
    Takada, R.
    Jinno, T.
    Koga, D.
    Hirao, M.
    Muneta, T.
    Okawa, A.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (06) : 717 - 721
  • [8] The relationship of polyethylene wear to particle size, distribution, and number: A possible factor explaining the risk of osteolysis after hip arthroplasty
    Gallo, Jiri
    Slouf, Miroslav
    Goodman, Stuart B.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2010, 94B (01) : 171 - 177
  • [9] Fifteen-Year Comparison of Wear and Osteolysis Analysis for Cross-Linked or Conventional Polyethylene in Cementless Total Hip Arthroplasty for Hip Dysplasia-A Retrospective Cohort Study
    Tsukamoto, Manabu
    Ohnishi, Hideo
    Mori, Toshiharu
    Kawasaki, Makoto
    Uchida, Soshi
    Sakai, Akinori
    JOURNAL OF ARTHROPLASTY, 2017, 32 (01): : 161 - +
  • [10] Clinical Results of the Wear Performance of Cross-Linked Polyethylene in Total Hip Arthroplasty Prospective Randomized Trial
    Ise, Kentaro
    Kawanabe, Keiichi
    Tamura, Jiro
    Akiyama, Haruhiko
    Goto, Koji
    Nakamura, Takashi
    JOURNAL OF ARTHROPLASTY, 2009, 24 (08): : 1216 - 1220