KGK-2-Type Detector of Gamma-Radiation Power for Diagnosis of Nuclear Reactor Radiation Fields within the Range from 1 μGy/s to 100 Gy/s

被引:0
作者
Koshelev, A. S. [1 ]
Dovbysh, L. Ye. [1 ]
Khoruzhy, V. Kh. [1 ]
Chuklyaev, S. V. [2 ]
机构
[1] Russian Fed Nucl Ctr, All Russian Res Inst Expt Phys, Nizhny Novgorod Oblast 607188, Sarov, Russia
[2] Res Inst Mat Technol, Moscow 123557, Russia
关键词
gamma dose rate; gas-filled gamma detector; pulsed nuclear reactor; postpulse relaxation;
D O I
10.1134/S1063778815110083
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The construction of the KGK-2-type detector of gamma-radiation power is briefly described. The diagnostic possibilities of the detector are shown by the example of results of the dose rate measurement in the energy start-ups of the BR-K1 and BR-1M reactors implemented in the mode of generating fission pulses on delayed neutrons. The possibilities of using the KGK-2 detector for postpulse gamma diagnostics are demonstrated by the example of results of measurements in the fission pulse on prompt neutrons of the BR-1M reactor.
引用
收藏
页码:1206 / 1212
页数:7
相关论文
共 9 条
[1]  
Bochvar I. A., 1977, THERMOLUMINESCENT DO
[2]  
Briskman BA, 1985, REACTOR DOSIMETRY PR
[3]  
Chuklyaev S. V., 1985, B IZOBRET
[4]  
Chuklyaev S. V., 1995, SECONDARY EMISSION I
[5]  
Generalova V. V., 2010, IZMER TEKH, P24
[6]  
Kolesov V. F., 2011, 65 YEARS ALL RUSS RE, P136
[7]  
KOSHELEV AS, 2011, FIZ YAD REAKT, V3, P10
[8]  
Sevast'yanov V. D., 2007, CHARACTERISTICS NEUT
[9]  
Zhitnik A. K., 2011, VOPR AT NAUKI TEKH M, P17