Numerical investigation of the impact of two-phase flow maldistribution on PEM fuel cell performance

被引:42
作者
Ding, Y. [1 ]
Bi, X. T. [1 ]
Wilkinson, D. P. [1 ]
机构
[1] Univ British Columbia, Dept Chem & Biol Engn, Clean Energy Res Ctr, Vancouver, BC V6T 1Z3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
PEM fuel cell; Two-phase flow model; VOF method; Flow maldistribution; Water management; PARALLEL-CHANNEL CONFIGURATIONS; PRESSURE-DROP HYSTERESIS; LIQUID WATER TRANSPORT; EX-SITU; MEMBRANE; SIMULATION; MICROCHANNEL; MANAGEMENT; MODEL; OPTIMIZATION;
D O I
10.1016/j.ijhydene.2013.10.047
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Flow maldistribution usually happens in PEM fuel cells when using common inlet and exit headers to supply reactant gases to multiple channels. As a result, some channels are flooded with more water and have less air flow while other channels are filled with less water but have excessive air flow. To investigate the impact of two-phase flow maldistribution on PEM fuel cell performance, a Volume of Fluid (VOF) model coupled with a 1D MEA model was employed to simulate two parallel channels. The slug flow pattern is mainly observed in the flow channels under different flow maldistribution conditions, and it significantly increases the gas diffusion layer (GDL) surface water coverage over the whole range of simulated current densities, which directly leads to poor fuel cell performance. Therefore, it is recommended that liquid and gas flow maldistribution in parallel channels should be avoided if possible over the whole range of operation. Increasing the gas stoichiometric flow ratio is not an effective method to mitigate the gas flow maldistribution, but adding a gas inlet resistance to the flow channel is effective in mitigating maldistribution. With a carefully selected value of the flow resistance coefficient, both the fuel cell performance and the gas flow distribution can be significantly improved without causing too much extra pressure drop. Copyright (C) 2013, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:469 / 480
页数:12
相关论文
共 53 条
[1]   Effect of operating parameters on the hygro-thermal stresses in proton exchange membranes of fuel cells [J].
Al-Baghdadi, Maher A. R. Sadiq ;
Al-Janabi, Haroun A. K. Shahad .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (17) :4510-4522
[2]   Two-phase flow pressure drop hysteresis in an operating proton exchange membrane fuel cell [J].
Anderson, Ryan ;
Wilkinson, David P. ;
Bi, Xiaotao ;
Zhang, L. .
JOURNAL OF POWER SOURCES, 2011, 196 (19) :8031-8040
[3]   Two-phase flow pressure drop hysteresis in parallel channels of a proton exchange membrane fuel cell [J].
Anderson, Ryan ;
Wilkinson, David P. ;
Bi, Xiaotao ;
Zhang, Lifeng .
JOURNAL OF POWER SOURCES, 2010, 195 (13) :4168-4176
[4]   Analytical model of flow maldistribution in polymer electrolyte fuel cell channels [J].
Basu, Suman ;
Wang, Chao-Yang ;
Chen, Kens. .
CHEMICAL ENGINEERING SCIENCE, 2010, 65 (23) :6145-6154
[5]   Two-Phase Flow Maldistribution and Mitigation in Polymer Electrolyte Fuel Cells [J].
Basu, Suman ;
Wang, Chao-Yang ;
Chen, Ken S. .
JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2009, 6 (03) :0310071-03100711
[6]   Two-phase flow and maldistribution in gas channels of a polymer electrolyte fuel cell [J].
Basu, Suman ;
Li, Jun ;
Wang, Chao-Yang .
JOURNAL OF POWER SOURCES, 2009, 187 (02) :431-443
[7]   Dynamic water transport and droplet emergence in PEMFC gas diffusion layers [J].
Bazylak, Aimy ;
Sinton, David ;
Djilali, Ned .
JOURNAL OF POWER SOURCES, 2008, 176 (01) :240-246
[8]   Water management in PEM fuel cells [J].
Berg, P ;
Promislow, K ;
St Pierre, J ;
Stumper, J ;
Wetton, B .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2004, 151 (03) :A341-A353
[9]   Two-phase flow distributors for fuel cell flow channels [J].
Bi, Hsiaotao T. ;
Sauriol, Pierre ;
Stumper, Juergen .
PARTICUOLOGY, 2010, 8 (06) :582-587
[10]   A CONTINUUM METHOD FOR MODELING SURFACE-TENSION [J].
BRACKBILL, JU ;
KOTHE, DB ;
ZEMACH, C .
JOURNAL OF COMPUTATIONAL PHYSICS, 1992, 100 (02) :335-354