Utility of endoscopic anatomical optical coherence tomography in functional rhinoplasty

被引:4
作者
Balakrishnan, Santosh [1 ]
Bu, Ruofei [1 ]
Waters, Candace M. [2 ]
Brandon, Bryan M. [2 ]
Kimbell, Julia S. [2 ]
Stepp, Wesley H. [2 ]
Shockley, William W. [2 ]
Clark, J. Madison [2 ]
Oldenburg, Amy L. [1 ,3 ,4 ]
机构
[1] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27515 USA
[2] Univ N Carolina, Sch Med, Dept Otolaryngol Head & Neck Surg, Chapel Hill, NC 27515 USA
[3] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27515 USA
[4] Univ N Carolina, Biomed Res Imaging Ctr, Chapel Hill, NC 27515 USA
基金
美国国家卫生研究院;
关键词
optical coherence tomography; endoscopic OCT; nasal valve compromise; functional rhinoplasty; nasal valve surgery; INTERNAL NASAL VALVE; COMPUTED-TOMOGRAPHY; DIAGNOSIS;
D O I
10.1117/1.JBO.25.1.016001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Objective measurement of the nasal valve region is valuable for the assessment of functional rhinoplasty surgical outcomes. Anatomical optical coherence tomography (aOCT) is an imaging modality that may be used to obtain real-time, quantitative, and volumetric scans of the nasal airway. We aim to evaluate if volumetric aOCT imaging is useful for the examination of the nasal valve region before and after functional rhinoplasty procedures. aOCT scans of the nasal valves were performed on four cadaveric heads before and after spreader graft and butterfly graft procedures. The resulting aOCT images were compared against video endoscopy images, and the segmented volumes of the nasal airway obtained from aOCT scans were compared with computed tomography (CT) derived volumes acquired under the same conditions. The aOCT-derived volumes match the CT volumes closely, with a mean Dice similarity coefficient of 0.88 and a mean Hausdorff distance of 2.3 mm. Furthermore, the aOCT images were found to represent the shape of the nasal cavity accurately. Due to its ability to perform real-time, quantitative, and accurate evaluation of the nasal airway, aOCT imaging is a promising modality for the objective assessment of the nasal valves before and after functional rhinoplasty procedures. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Utility of optical coherence tomography in a case of bilateral congenital macular coloboma
    Munoz de Escalona Rojas, Jose Enrique
    Quereda Castaneda, Aurora
    Garcia Garcia, Olga
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (09) : 683 - U122
  • [42] Utility of optical coherence tomography and intravascular ultrasound for the evaluation of coronary lesions
    Girassolli, Agustin
    Carrizo, Sebastian
    Jimenez-Valero, Santiago
    Sanchez Recalde, Angel
    Ruiz Garcia, Juan
    Galeotte, Guillermo
    Moreno, Raul
    [J]. REVISTA PORTUGUESA DE CARDIOLOGIA, 2013, 32 (11) : 925 - 929
  • [43] Anatomical and Functional Changes in the Coexistence of Vitreomacular Traction and Epiretinal Membrane: A Spectral-Domain Optical Coherence Tomography Study
    Chatziralli, Irini
    Theodossiadis, George
    Datseris, Ioannis
    Parikakis, Efstratios
    Theodossiadis, Panagiotis
    [J]. OPHTHALMIC RESEARCH, 2017, 57 (01) : 54 - 59
  • [44] Miniaturized Endoscopic Probe for Optical Coherence Tomography with Magnet Driving Device
    Pang, Ziwei
    Wu, Jigang
    [J]. 2015 OPTO-ELECTRONICS AND COMMUNICATIONS CONFERENCE (OECC), 2015,
  • [45] Design of the probe of swept source optical coherence tomography for endoscopic imaging
    Bian H.-Y.
    Gao W.-R.
    Liao J.-L.
    [J]. Guangzi Xuebao/Acta Photonica Sinica, 2016, 45 (09):
  • [46] 2mm Catheter design for endoscopic optical coherence tomography
    Lee, Kye-Sung
    Koehler, Chuck
    Johnson, Eric G.
    Teuma, Eric Valaski
    Ilegbusi, Olusegun
    Costa, Marco
    Xie, Huikai
    Rolland, Jannick P.
    [J]. INTERNATIONAL OPTICAL DESIGN CONFERENCE 2006, PTS 1 AND 2, 2006, 6342
  • [47] A two-axis electrothermal micromirror for endoscopic optical coherence tomography
    Jain, A
    Kopa, A
    Pan, YT
    Fedder, GK
    Xie, HK
    [J]. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2004, 10 (03) : 636 - 642
  • [48] Pneumatically-actuated tunable microlens for endoscopic optical coherence tomography
    Aljasem, Khaled
    Werber, Armin
    Reichelt, Stephan
    Mader, Daniel
    Zappe, Hans
    [J]. TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [49] Micro-structured glass probe for endoscopic Optical Coherence Tomography
    Gonzalez-Cerdas, Gerardo E.
    Stein, Patrick
    Kretschmer, Simon
    Bauer, Christoph
    Sandic, Dragan
    Ataman, Caglar
    Zappe, Hans
    [J]. BIOMEDICAL SPECTROSCOPY, MICROSCOPY, AND IMAGING, 2020, 11359
  • [50] Simultaneous dual-band optical coherence tomography for endoscopic applications
    Xu, Jianbing
    Yu, Luoqin
    Wei, Xiaoming
    Wang, Xie
    Chui, Po Ching
    Chan, Kin Tak
    Lam, Edmund Y.
    Lee, Nikki P.
    Wong, Kenneth K. Y.