Utility of endoscopic anatomical optical coherence tomography in functional rhinoplasty

被引:4
作者
Balakrishnan, Santosh [1 ]
Bu, Ruofei [1 ]
Waters, Candace M. [2 ]
Brandon, Bryan M. [2 ]
Kimbell, Julia S. [2 ]
Stepp, Wesley H. [2 ]
Shockley, William W. [2 ]
Clark, J. Madison [2 ]
Oldenburg, Amy L. [1 ,3 ,4 ]
机构
[1] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27515 USA
[2] Univ N Carolina, Sch Med, Dept Otolaryngol Head & Neck Surg, Chapel Hill, NC 27515 USA
[3] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27515 USA
[4] Univ N Carolina, Biomed Res Imaging Ctr, Chapel Hill, NC 27515 USA
基金
美国国家卫生研究院;
关键词
optical coherence tomography; endoscopic OCT; nasal valve compromise; functional rhinoplasty; nasal valve surgery; INTERNAL NASAL VALVE; COMPUTED-TOMOGRAPHY; DIAGNOSIS;
D O I
10.1117/1.JBO.25.1.016001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Objective measurement of the nasal valve region is valuable for the assessment of functional rhinoplasty surgical outcomes. Anatomical optical coherence tomography (aOCT) is an imaging modality that may be used to obtain real-time, quantitative, and volumetric scans of the nasal airway. We aim to evaluate if volumetric aOCT imaging is useful for the examination of the nasal valve region before and after functional rhinoplasty procedures. aOCT scans of the nasal valves were performed on four cadaveric heads before and after spreader graft and butterfly graft procedures. The resulting aOCT images were compared against video endoscopy images, and the segmented volumes of the nasal airway obtained from aOCT scans were compared with computed tomography (CT) derived volumes acquired under the same conditions. The aOCT-derived volumes match the CT volumes closely, with a mean Dice similarity coefficient of 0.88 and a mean Hausdorff distance of 2.3 mm. Furthermore, the aOCT images were found to represent the shape of the nasal cavity accurately. Due to its ability to perform real-time, quantitative, and accurate evaluation of the nasal airway, aOCT imaging is a promising modality for the objective assessment of the nasal valves before and after functional rhinoplasty procedures. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.
引用
收藏
页数:11
相关论文
共 22 条
[1]   Quantitative upper airway imaging with anatomic optical coherence tomography [J].
Armstrong, JJ ;
Leigh, MS ;
Sampson, DD ;
Walsh, JH ;
Hillman, DR ;
Eastwood, PR .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2006, 173 (02) :226-233
[2]   Combined anatomical optical coherence tomography and intraluminal pressure reveal viscoelasticity of the in vivo airway [J].
Balakrishnan, Santosh ;
Bu, Ruofei ;
Iftimia, Nicusor ;
Price, Hillel ;
Zdanski, Carlton ;
Oldenburg, Amy L. .
JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (10)
[3]   Reformatted Computed Tomography to Assess the Internal Nasal Valve and Association With Physical Examination [J].
Bloom, Jason D. ;
Sridharan, Shaum ;
Hagiwara, Mari ;
Babb, James S. ;
White, W. Matthew ;
Constantinides, Minas .
ARCHIVES OF FACIAL PLASTIC SURGERY, 2012, 14 (05) :331-335
[4]   Airway compliance measured by anatomic optical coherence tomography [J].
Bu, Ruofei ;
Balakrishnan, Santosh ;
Iftimia, Nicusor ;
Price, Hillel ;
Zdanski, Carlton ;
Oldenburg, Amy L. .
BIOMEDICAL OPTICS EXPRESS, 2017, 8 (04) :2195-2209
[5]  
Cakmak Ö, 2003, LARYNGOSCOPE, V113, P295
[6]   Evidence-Based Practice Functional Rhinoplasty [J].
Cannon, Daniel E. ;
Rhee, John S. .
OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 2012, 45 (05) :1033-+
[7]  
Chandra RK, 2009, OTOLARYNG CLIN N AM, V42, P207, DOI [10.1016/j.otc.2009.07.010, 10.1016/j.otc.2009.01.004]
[8]   In vivo imaging of the internal nasal valve during different conditions using optical coherence tomography [J].
Englhard, Anna S. ;
Wiedmann, Maximilian ;
Ledderose, Georg J. ;
Lemieux, Bryan ;
Badran, Alan ;
Jing, Joseph C. ;
Chen, Zhongping ;
Volgger, Veronika ;
Wong, Brian J. F. .
LARYNGOSCOPE, 2018, 128 (03) :E105-E110
[9]   Imaging of the internal nasal valve using long-range Fourier domain optical coherence tomography [J].
Englhard, Anna S. ;
Wiedmann, Maximilian ;
Ledderose, Georg J. ;
Lemieux, Bryan ;
Badran, Alan ;
Chen, Zhongping ;
Betz, Christian S. ;
Wong, Brian J. .
LARYNGOSCOPE, 2016, 126 (03) :E97-E102
[10]  
Fujimoto JG., 2015, OPTICAL COHERENCE TO, DOI [DOI 10.1007/978-3-319-06419-2_1, 10.1007/978-3-319-06419-21, DOI 10.1007/978-3-319-06419-21, 10.1007/978-3-319-06419-2_1]