Concurrent Validity by Comparing EMG Activity between Manual Muscle Testing, Handheld Dynamometer, and Stationary Dynamometer in Testing of Maximal Isometric Quadriceps Contraction

被引:6
作者
Lee, Tae-Heon [1 ]
Park, Kyeong-Soon [1 ]
Lee, Dong-Geol [1 ]
Lee, Nam-Gi [2 ]
机构
[1] Chungnam Natl Univ Hosp, Dept Rehabil Med, Taejon, South Korea
[2] Yonsei Univ, Grad Sch, Dept Phys Therapy, Wonju, Kangwon Do, South Korea
关键词
Electromyography; Maximal voluntary isometric contraction; Normalization; ISOKINETIC DYNAMOMETRY; RELIABILITY; STRENGTH; NORMALIZATION; FEMORIS; AMPLITUDE; TORQUE; ADULTS;
D O I
10.1589/jpts.24.1219
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
[Purpose] The purpose of this study was to establish the concurrent validity of electromyography (EMG) activity and muscle strength scores obtained by manual muscle testing (MMT), handheld dynamometer (HHD), and the gold standard stationary dynamometer (SD). [Subjects] Forty healthy young adults (17 men, 23 women) volunteered to participate in this study. [Methods] Subjects performed maximal voluntary isometric contraction (MVIC) of the quadriceps for 5 seconds in three successive trials. Surface EMG was used for recording the muscle activity during the maximal MMT, HHD, and SD measurements. [Results] The mean and peak EMG amplitudes (ICC3,k = 0.968 to 0.980) of the three MVIC methods and muscle strength scores (Pearson r = 0.868) measured by HHD and SD showed good concurrent validity. The intra-trial reliability of mean EMG activity was also good (ICC3,1 = 0.960 to 0.989), reflecting consistent measurement between trials. [Conclusion] Our EMG results imply that MMT and HHD are useful and simple methods of measuring MVIC for EMG normalization. Considering cost, time, and clinical utility, we suggest that the use of HHD to measure MVIC for EMG normalization is highly valuable and should generate more meaningful information associated with pathological conditions or interventions for all patients.
引用
收藏
页码:1219 / 1223
页数:5
相关论文
共 39 条
[1]   EMG SIGNAL AMPLITUDE NORMALIZATION TECHNIQUE IN STRETCH-SHORTENING CYCLE MOVEMENTS [J].
ALLISON, GT ;
MARSHALL, RN ;
SINGER, KP .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1993, 3 (04) :236-244
[2]  
Araujo R C, 2000, Electromyogr Clin Neurophysiol, V40, P225
[3]   Testing apparatus and experimental procedure for position specific normalization of electromyographic measurements of distal upper extremity musculature [J].
Barr, AE ;
Goldsheyder, D ;
Özkaya, N ;
Nordin, M .
CLINICAL BIOMECHANICS, 2001, 16 (07) :576-585
[4]  
Beasley WC, 1956, PHYS THER, V66, P206
[5]   Reference values for extremity muscle strength obtained by hand-held dynamometry from adults aged 20 to 79 years [J].
Bohannon, RW .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1997, 78 (01) :26-32
[6]   INTERRATER RELIABILITY OF HAND-HELD DYNAMOMETRY [J].
BOHANNON, RW ;
ANDREWS, AW .
PHYSICAL THERAPY, 1987, 67 (06) :931-933
[7]   TEST-RETEST RELIABILITY OF HAND-HELD DYNAMOMETRY DURING A SINGLE SESSION OF STRENGTH ASSESSMENT [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1986, 66 (02) :206-209
[8]   Intertester reliability of hand-held dynamometry: A concise summary of published research [J].
Bohannon, RW .
PERCEPTUAL AND MOTOR SKILLS, 1999, 88 (03) :899-902
[9]   HAND-HELD COMPARED WITH ISOKINETIC DYNAMOMETRY FOR MEASUREMENT OF STATIC KNEE EXTENSION TORQUE (PARALLEL RELIABILITY OF DYNAMOMETERS) [J].
BOHANNON, RW .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (03) :217-222
[10]  
Cram J.R., 1998, INTRO SURFACE ELECTR, P363