Central corneal thickness and corneal volume changes in eyes with and without pseudoexfoliation after uneventful phacoemulsification

被引:7
作者
Asfuroglu, Yonca [1 ]
Kemer, Ozlem Evren [2 ]
机构
[1] Osmancik State Hosp, Omer Derindere Blvd 105, TR-19500 Osmancik, Corum, Turkey
[2] Univ Hlth Sci, Numune Educ & Res Hosp, Talatpasa Blvd 44, TR-06230 Ankara, Turkey
关键词
Central corneal thickness; Corneal volume; Phacoemulsification; Pseudoexfoliation; The Pentacam; ANTERIOR SEGMENT PARAMETERS; SPECULAR MICROSCOPY; CATARACT-SURGERY; PENTACAM; ENDOTHELIUM; PACHYMETER; DAMAGE;
D O I
10.1007/s10792-017-0804-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AimTo investigate the effects of uneventful phacoemulsification on central corneal thickness (CCT) and corneal volume (CV) in pseudoexfoliative eyes during a 3months postoperative period and compare these changes to eyes without pseudoexfoliation (PEX) syndrome. Another purpose of this study was to compare the CCT measurements done by ultrasound pachymetry (UP) with those done by the Oculus Pentacam.Material and methodA total of 42 eyes of 42 consecutive patients with cataracts and PEX syndrome that underwent uneventful phacoemulsification were enrolled in this prospective study. A control group of 42 eyes of 42 patients with cataracts/without PEX was employed for comparison. CV and CCT measurements were obtained preoperatively and at 1 and 3months postoperatively with the Pentacam. CCT values were also measured with UP. T test and Wilcoxon sign test were used to compare the variables.ResultsThe mean age of the patients was 72.18.3 and 66.6 +/- 9.6years in PEX and non-PEX group, respectively. In both groups, there were no significant differences between preoperative and postoperative CV (Fig.1), CCT by the Pentacam (Fig.2) and CCT by UP (Fig.3) values (p>0.05). CCT measurements obtained by two devices were also similar, and there were no statistically significant differences (p>0.05). Changes in CV and CCT remained stabile at 3months postoperatively.Conclusion p id=Par4 Eyes with and without PEX syndrome exhibit similar corneal features before and after phacoemulsification. A surgery in early stages of cataracts in PEX syndrome, not only provides a non-complicated surgery, but also leads to a less damaged cornea similar to eyes without PEX.
引用
收藏
页码:275 / 280
页数:6
相关论文
共 30 条
[1]   Evaluation of Anterior Segment Parameters in Pseudoexfoliation Syndrome Patients [J].
Acar, Banu Torun ;
Buttanri, Ibrahim Bulent ;
Sevim, Mehmet Sahin ;
Esen, Didem ;
Acar, Suphi .
TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2010, 40 (04) :217-221
[2]   Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry [J].
Barkana, Y ;
Gerber, Y ;
Elbaz, U ;
Schwartz, S ;
Ken-Dror, G ;
Avni, I ;
Zadok, D .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1729-1735
[3]   Cataract surgery in pseudoexfoliation syndrome [J].
Belovay, Graham W. ;
Varma, Devesh K. ;
Ahmed, Iqbal Ike K. .
CURRENT OPINION IN OPHTHALMOLOGY, 2010, 21 (01) :25-34
[4]   SPECULAR MICROSCOPY OF HUMAN CORNEAL ENDOTHELIUM INVIVO [J].
BOURNE, WM ;
KAUFMAN, HE .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1976, 81 (03) :319-323
[5]   Effect of torsional mode phacoemulsification on cornea in eyes with/without pseudoexfoliation [J].
Damircan, Suleyman ;
Atas, Mustafa ;
Yurtsever, Yusufcan .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (02) :281-287
[6]   Central Corneal Thickness and Biomechanical Changes After Clear Corneal Phacoemulsification [J].
de Freitas, Bruno ;
Ventura, Marcelo Palis ;
da Silva, Renata Siqueira ;
Canedo, Ana Laura ;
Velarde, Guillermo Coca ;
Ambrosio, Renato, Jr. .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (03) :215-219
[7]   Evaluation of Pentacam-Scheimpflug imaging of anterior segment parameters in patients with pseudoexfoliation syndrome and pseudoexfoliative glaucoma [J].
Doganay, Selim ;
Tasar, Ahmet ;
Cankaya, Cem ;
Firat, Penpe Gul ;
Yologlu, Saim .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2012, 95 (02) :218-222
[8]   The effects of eye drops on corneal thickness in adult myopia [J].
Gao, Lei ;
Fan, Huijun ;
Cheng, Arthur C. K. ;
Wang, Zhonghao ;
Lam, Dennis S. C. .
CORNEA, 2006, 25 (04) :404-407
[9]  
Grewal SPS, 2001, HIGHLIGHTS OPHTALMOL, V36, P17
[10]   Corneal endothelial damage after cataract surgery in eyes with pseudoexfoliation syndrome [J].
Hayashi, Ken ;
Manabe, Shin-ichi ;
Yoshimura, Koichi ;
Kondo, Hiroyuki .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (06) :881-887