Comparison of Noninvasive Assessments of Central Blood Pressure Using General Transfer Function and Late Systolic Shoulder of the Radial Pressure Wave

被引:11
|
作者
Wohlfahrt, Peter [1 ,2 ,3 ,4 ]
Krajcoviechova, Alena [1 ,2 ]
Seidlerova, Jitka [5 ]
Mayer, Otto [5 ]
Filipovsky, Jan [5 ]
Cifkova, Renata [1 ,2 ,3 ,4 ,6 ]
机构
[1] Charles Univ Prague, Fac Med 1, Ctr Cardiovasc Prevent, Prague, Czech Republic
[2] Thomayer Hosp, Prague, Czech Republic
[3] Inst Clin & Expt Med, Dept Prevent Cardiol, Prague, Czech Republic
[4] St Annes Univ Hosp Brno, Int Clin Res Ctr, Brno, Czech Republic
[5] Charles Univ Prague, Fac Med, Ctr Hypertens, Dept Internal Med 2, Plzen, Czech Republic
[6] Charles Univ Prague, Fac Med 1, Dept Cardiol & Angiol, Prague, Czech Republic
关键词
applanation tonometry; blood pressure; central systolic blood pressure; generalized transfer function; hypertension; radial pulse wave; radial second systolic pressure; CENTRAL AORTIC PRESSURE; CARDIOVASCULAR RISK-FACTORS; CZECH POST-MONICA; LONGITUDINAL TRENDS; PULSE PRESSURE; HYPERTENSION; VARIABILITY; VALIDATION; SPHYGMOCOR; AMPLIFICATION;
D O I
10.1093/ajh/hpt166
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Central systolic blood pressure (cSBP) can be derived by the general transfer function of the radial pressure wave, as used in the SphygmoCor device, or by regression equation from directly measured late systolic shoulder of the radial pressure wave (pSBP2), as used in the Omron HEM-9000AI device. The aim of this study was to compare the SphygmoCor estimates of cSBP with 2 estimates of cSBP provided by the Omron HEM-9000AI (cSBP, pSBP2) in a large cohort of the white population. In 391 patients aged 52.313.5 years (46% men) from the Czech post-MONICA Study, cSBP was measured using the SphygmoCor and Omron HEM-9000AI devices in random order. Omron cSBP and pSBP2 were perfectly correlated (r 1.0; P < 0.0001). There was a strong correlation (r 0.97; P < 0.0001) between Omron and SphygmoCor cSBP estimates, but Omron estimate was 13.14.7mm Hg higher than SphygmoCor cSBP. On the other hand, Omron pSBP2 strongly correlated with SphygmoCor cSBP (r 0.97; P < 0.0001) and was 1.74.2mm Hg lower than SphygmoCor cSBP. In multivariable analysis, anthropometric and cardiovascular risk factors explained only 10% of the variance of the cSBP difference between devices while explaining 52% of the systolic blood pressure amplification variance. Estimation of cSBP based on the late systolic shoulder of the radial wave provides a comparable accuracy with the validated general transfer function. When comparing Omron HEM-9000AI and SphygmoCor estimates of cSBP, Omron pSBP2 should be used. The difference between both devices in cSBP may be explained by differences in calibration.
引用
收藏
页码:162 / 168
页数:7
相关论文
共 50 条
  • [31] Estimation of aortic systolic blood pressure from radial systolic and diastolic blood pressures alone using artificial neural networks
    Xiao, Hanguang
    Qasem, Ahmad
    Butlin, Mark
    Avolio, Alberto
    JOURNAL OF HYPERTENSION, 2017, 35 (08) : 1577 - 1585
  • [32] Associations of serum uric acid levels with arterial wave reflections and central systolic blood pressure
    Hsu, Pai-Feng
    Chuang, Shao-Yuan
    Cheng, Hao-Min
    Sung, Shih-Hsien
    Ting, Chih-Tai
    Lakatta, Edward G.
    Yin, Frank C. P.
    Chou, Pesus
    Chen, Chen-Huan
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (03) : 2057 - 2063
  • [33] Subject-Specific Estimation of Central Aortic Blood Pressure Using an Individualized Transfer Function: A Preliminary Feasibility Study
    Hahn, Jin-Oh
    Reisner, Andrew T.
    Jaffer, Farouc A.
    Asada, H. Harry
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2012, 16 (02): : 212 - 220
  • [34] Accuracy of noninvasive central blood pressure estimation: still a long 'wave' to go
    Pucci, Giacomo
    Vaudo, Gaetano
    Picone, Dean S.
    JOURNAL OF HYPERTENSION, 2020, 38 (11) : 2146 - 2147
  • [35] Estimation of central blood pressure using radial pulse waveform
    Wei, Ran
    Im, Jae Joong
    Park, Sung Ha
    Jung, Nam Sik
    2007 INTERNATIONAL SYMPOSIUM ON INFORMATION TECHNOLOGY CONVERGENCE, PROCEEDINGS, 2007, : 250 - +
  • [36] Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry
    Fetics, B
    Nevo, E
    Chen, CH
    Kass, DA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (06) : 698 - 706
  • [37] Estimating central systolic blood pressure during oscillometric determination of blood pressure: proof of concept and validation by comparison with intra-aortic pressure recording and arterial tonometry
    Brett, Sally Emma
    Guilcher, Antoine
    Clapp, Brian
    Chowienczyk, Phil
    BLOOD PRESSURE MONITORING, 2012, 17 (03) : 132 - 136
  • [38] Comparison of noninvasive devices for assessing central blood pressure parameters: what to compare, when and why
    Cameron, James D.
    JOURNAL OF HYPERTENSION, 2013, 31 (01) : 27 - 31
  • [39] Tissue Doppler indexes of left ventricular systolic function in relation to the pulsatile and steady components of blood pressure in a general population
    Sakiewicz, Wojciech
    Kuznetsova, Tatiana
    Kloch-Badelek, Malgorzata
    D'hooge, Jan
    Ryabikov, Andrew
    Kunicka, Katarzyna
    Swierblewska, Ewa
    Thijs, Lutgarde
    Jin, Yu
    Loster, Magdalena
    Malyutina, Sofia
    Stolarz-Skrzypek, Katarzyna
    Kawecka-Jaszcz, Kalina
    Narkiewicz, Krzysztof
    Staessen, Jan A.
    JOURNAL OF HYPERTENSION, 2012, 30 (02) : 403 - 410
  • [40] A New Method to Estimate Aortic Pulse Wave Velocity and Central Systolic Blood Pressure by Measuring Brachial Cuff Pulse Waveform
    Shiina, Kazuki
    Tomiyama, Hirofumi
    Odaira, Mari
    Yoshida, Masanobu
    Yamashina, Akira
    Kobayashi, Tatsuya
    Fujii, Kenji
    Ogura, Toshihiko
    CIRCULATION, 2011, 124 (21)