Comparison of Noninvasive Assessments of Central Blood Pressure Using General Transfer Function and Late Systolic Shoulder of the Radial Pressure Wave

被引:11
|
作者
Wohlfahrt, Peter [1 ,2 ,3 ,4 ]
Krajcoviechova, Alena [1 ,2 ]
Seidlerova, Jitka [5 ]
Mayer, Otto [5 ]
Filipovsky, Jan [5 ]
Cifkova, Renata [1 ,2 ,3 ,4 ,6 ]
机构
[1] Charles Univ Prague, Fac Med 1, Ctr Cardiovasc Prevent, Prague, Czech Republic
[2] Thomayer Hosp, Prague, Czech Republic
[3] Inst Clin & Expt Med, Dept Prevent Cardiol, Prague, Czech Republic
[4] St Annes Univ Hosp Brno, Int Clin Res Ctr, Brno, Czech Republic
[5] Charles Univ Prague, Fac Med, Ctr Hypertens, Dept Internal Med 2, Plzen, Czech Republic
[6] Charles Univ Prague, Fac Med 1, Dept Cardiol & Angiol, Prague, Czech Republic
关键词
applanation tonometry; blood pressure; central systolic blood pressure; generalized transfer function; hypertension; radial pulse wave; radial second systolic pressure; CENTRAL AORTIC PRESSURE; CARDIOVASCULAR RISK-FACTORS; CZECH POST-MONICA; LONGITUDINAL TRENDS; PULSE PRESSURE; HYPERTENSION; VARIABILITY; VALIDATION; SPHYGMOCOR; AMPLIFICATION;
D O I
10.1093/ajh/hpt166
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Central systolic blood pressure (cSBP) can be derived by the general transfer function of the radial pressure wave, as used in the SphygmoCor device, or by regression equation from directly measured late systolic shoulder of the radial pressure wave (pSBP2), as used in the Omron HEM-9000AI device. The aim of this study was to compare the SphygmoCor estimates of cSBP with 2 estimates of cSBP provided by the Omron HEM-9000AI (cSBP, pSBP2) in a large cohort of the white population. In 391 patients aged 52.313.5 years (46% men) from the Czech post-MONICA Study, cSBP was measured using the SphygmoCor and Omron HEM-9000AI devices in random order. Omron cSBP and pSBP2 were perfectly correlated (r 1.0; P < 0.0001). There was a strong correlation (r 0.97; P < 0.0001) between Omron and SphygmoCor cSBP estimates, but Omron estimate was 13.14.7mm Hg higher than SphygmoCor cSBP. On the other hand, Omron pSBP2 strongly correlated with SphygmoCor cSBP (r 0.97; P < 0.0001) and was 1.74.2mm Hg lower than SphygmoCor cSBP. In multivariable analysis, anthropometric and cardiovascular risk factors explained only 10% of the variance of the cSBP difference between devices while explaining 52% of the systolic blood pressure amplification variance. Estimation of cSBP based on the late systolic shoulder of the radial wave provides a comparable accuracy with the validated general transfer function. When comparing Omron HEM-9000AI and SphygmoCor estimates of cSBP, Omron pSBP2 should be used. The difference between both devices in cSBP may be explained by differences in calibration.
引用
收藏
页码:162 / 168
页数:7
相关论文
共 50 条
  • [21] Estimation of Central Systolic Blood Pressure from Peripheral Pressure Waves using a Novel Second Systolic Pressure-Based Method in Normal and Heritable Hypercholesterolemic Rabbits
    Katsuda, Shin-ichiro
    Hazama, Akihiro
    JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2023, 30 (09) : 1132 - 1141
  • [22] Calibration of noninvasive central blood pressure devices and negative aortic-to-brachial systolic pressure amplification
    Papaioannou, Theodore G.
    Vavuranakis, Manolis
    Tousoulis, Dimitrios
    KIDNEY INTERNATIONAL, 2017, 91 (01) : 253 - 254
  • [23] Development and Validation of a Novel Method to Derive Central Aortic Systolic Pressure From the Radial Pressure Waveform Using an N-Point Moving Average Method
    Williams, Bryan
    Lacy, Peter S.
    Yan, Peter
    Hwee, Chua-Ngak
    Liang, Chen
    Ting, Choon-Meng
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (08) : 951 - 961
  • [24] Measurement of Central Aortic Pulse Pressure: Noninvasive Brachial Cuff-Based Estimation by a Transfer Function Vs. a Novel Pulse Wave Analysis Method
    Cheng, Hao-Min
    Sung, Shih-Hsien
    Shih, Yuan-Ta
    Chuang, Shao-Yuan
    Yu, Wen-Chung
    Chen, Chen-Huan
    AMERICAN JOURNAL OF HYPERTENSION, 2012, 25 (11) : 1162 - 1169
  • [25] Brachial Blood Pressure-Independent Relations Between Radial Late Systolic Shoulder-Derived Aortic Pressures and Target Organ Changes
    Norton, Gavin R.
    Majane, Olebogeng H. I.
    Maseko, Muzi J.
    Libhaber, Carlos
    Redelinghuys, Michelle
    Kruger, Deirdre
    Veller, Martin
    Sareli, Pinhas
    Woodiwiss, Angela J.
    HYPERTENSION, 2012, 59 (04) : 885 - U295
  • [26] Non-Invasive Estimation of Central Systolic Blood Pressure by Radial Tonometry: A Simplified Approach
    Chemla, Denis
    Agnoletti, Davide
    Jozwiak, Mathieu
    Zhang, Yi
    Protogerou, Athanase D.
    Millasseau, Sandrine
    Blacher, Jacques
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (08):
  • [27] Noninvasive central systolic blood pressure, not peripheral systolic blood pressure, independently predicts the progression of carotid intima-media thickness in a Chinese community-based population
    Pengfei Sun
    Ying Yang
    Guanliang Cheng
    Fangfang Fan
    Litong Qi
    Lan Gao
    Xiaoning Han
    Jia Jia
    Yong Huo
    Yan Zhang
    Hypertension Research, 2019, 42 : 392 - 399
  • [28] Estimation of central aortic systolic pressure using late systolic inflection of radial artery pulse and its application to vasodilator therapy
    Takazawa, Kenji
    Kobayashi, Hiroshi
    Kojima, Iwao
    Aizawa, Akira
    Kinoh, Mineko
    Sugo, Yumi
    Shimizu, Masayuki
    Miyawaki, Yoshinori
    Tanaka, Nobuhiro
    Yamashina, Akira
    Avolio, Alberto
    JOURNAL OF HYPERTENSION, 2012, 30 (05) : 908 - 916
  • [29] Calibration of noninvasive central blood pressure devices and negative aortic-to-brachial systolic pressure amplification Reply
    Carlsen, Rasmus K.
    Peters, Christian D.
    Khatir, Dinah S.
    Laugesen, Esben
    Botker, Hans Erik
    Winther, Simon
    Buus, Niels H.
    KIDNEY INTERNATIONAL, 2017, 91 (01) : 254 - 254
  • [30] Validation of a generalized transfer function to noninvasively derive central blood pressure during exercise
    Sharman, JE
    Lim, R
    Qasem, AM
    Coombes, JS
    Burgess, MI
    Franco, J
    Garrahy, P
    Wilkinson, IB
    Marwick, TH
    HYPERTENSION, 2006, 47 (06) : 1203 - 1208