Use of Diffuse Optical Spectroscopy to Monitor Muscle and Brain Oxygenation Dynamics During Isometric and Isokinetic Exercise

被引:2
|
作者
Ganesan, Goutham [1 ,2 ]
Cotter, Joshua [3 ]
Reuland, Warren [1 ]
Warren, Robert V. [1 ]
Zarandi, Soroush M. Mirzaei [1 ]
Cerussi, Albert E. [2 ]
Tromberg, Bruce J. [1 ]
Galassetti, Pietro [2 ]
机构
[1] Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92715 USA
[2] Univ Calif Irvine, Sch Med, Dept Pediat, Irvine, CA USA
[3] Univ Calif Irvine, Sch Med, Dept Orthoped Surg, Irvine, CA USA
来源
OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE X | 2013年 / 8578卷
基金
美国国家卫生研究院;
关键词
resistance training; exercise; blood flow restriction; fatigue; spectroscopy; scattering; NEAR-INFRARED SPECTROSCOPY; RESISTANCE EXERCISE; HEMOGLOBIN; ATROPHY; HEALTH;
D O I
10.1117/12.2007459
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The use of near-infrared time-resolved spectroscopy (TRS-20, Hamamatsu Corporation) in two resistance type exercise applications in human subjects is described. First, using isometric flexion of the biceps, we compared the magnitude and relevance of tissue hemoglobin concentration and oxygen saturation (stO2) changes when assuming constant scattering versus continuous measurement of reduced scattering coefficients at three wavelengths. It was found that the assumption of constant scattering resulted in significant errors in hemoglobin concentration assessment during sustained isometric contractions. Secondly, we tested the effect of blood flow restriction (BFR) on oxygenation in a muscle (vastus medialis oblique, VMO) and in the prefrontal cortex (PFC) of the brain. The BFR training technique resulted in considerably more fatigability in subjects, and correlated with reduced muscle stO2 between sets of exertion. Additionally, exercise with BFR resulted in greater PFC deoxygenation than a condition with equivalent work performance but no BFR. These experiments demonstrate novel applications for diffuse optical spectroscopy in strength testing and targeted muscle rehabilitation.
引用
收藏
页数:10
相关论文
共 35 条
  • [1] Muscle oxygenation and EMG activity during isometric exercise in children
    Moalla, Wassim
    Merzouk, Abdallah
    Costes, Frederic
    Tabka, Zouhair
    Ahmaidi, Said
    JOURNAL OF SPORTS SCIENCES, 2006, 24 (11) : 1195 - 1201
  • [2] Skeletal muscle and cerebral oxygenation levels during and after submaximal concentric and eccentric isokinetic exercise
    Cherouveim, Evgenia D.
    Margaritelis, Nikos, V
    Koulouvaris, Panagiotis
    Tsolakis, Charis
    Malliou, Vasiliki J.
    Chatzinikolaou, Panagiotis N.
    Franchi, Martino, V
    Porcelli, Simone
    Kyparos, Antonios
    Vrabas, Ioannis S.
    Geladas, Nikos D.
    Nikolaidis, Michalis G.
    Paschalis, Vassilis
    JOURNAL OF SPORTS SCIENCES, 2022, 40 (02) : 195 - 202
  • [3] Monitoring adaptation of skin tissue oxygenation during cycling ergometer exercise by frequency-domain diffuse optical spectroscopy
    Tseng, Sheng-Hao
    Liang, Bo-Jian
    Wang, Wen
    Tsai, Bo-Xiang
    Hu, Po-Sheng
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (08) : 5023 - 5036
  • [4] Heterogeneous oxygenation in nonexercising triceps surae muscle during contralateral isometric exercise
    Mizuno, Masaki
    Tokizawa, Ken
    Muraoka, Isao
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2006, 97 (02) : 181 - 188
  • [5] Heterogeneous oxygenation in nonexercising triceps surae muscle during contralateral isometric exercise
    Masaki Mizuno
    Ken Tokizawa
    Isao Muraoka
    European Journal of Applied Physiology, 2006, 97 : 181 - 188
  • [6] Comparison of forearm muscle oxygenation dynamics during isometric and isotonic contractions monitored by near-infrared spectroscopy
    Cheung, A.
    Tu, L.
    Sahragard, F.
    Shadgan, B.
    BIOPHOTONICS IN EXERCISE SCIENCE, SPORTS MEDICINE, HEALTH MONITORING TECHNOLOGIES, AND WEARABLES, 2020, 11237
  • [7] Tissue oxygenation by near-infrared spectroscopy and muscle blood flow during isometric contractions of the forearm
    Hicks, A
    McGill, S
    Hughson, RL
    CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 1999, 24 (03): : 216 - 230
  • [8] Reliability of near-infrared spectroscopy in measuring muscle oxygenation during squat exercise
    Corral-Perez, Juan
    Marin-Galindo, Alberto
    Costilla, Manuel
    Casals, Cristina
    Munoz-Lopez, Alejandro
    Sanchez-Sixto, Alberto
    Sanudo, Borja
    Ponce-Gonzalez, Jesus Gustavo
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2024, 27 (11) : 805 - 813
  • [9] Near-infrared spectroscopy determined brain and muscle oxygenation during exercise with normal and resistive breathing
    Nielsen, HB
    Boesen, M
    Secher, NH
    ACTA PHYSIOLOGICA SCANDINAVICA, 2001, 171 (01): : 63 - 70
  • [10] No alteration of back muscle oxygenation during isometric exercise in individuals with non-specific low back pain
    Langenfeld, Anke
    Wirth, Brigitte
    Scherer-Vrana, Andrea
    Riner, Fabienne
    Gaehwiler, Kyra
    Valdivieso, Paola
    Humphreys, B. Kim
    Scholkmann, Felix
    Flueck, Martin
    Schweinhardt, Petra
    SCIENTIFIC REPORTS, 2022, 12 (01)