Ambient detection of CH4 and N2O by Quantum Cascade Laser

被引:13
作者
Castillo, Paulo Cesar [1 ]
Sydoryk, Ihor [1 ]
Gross, Barry [1 ]
Moshary, Fred [1 ]
机构
[1] CUNY City Coll, Opt Remote Sensing Lab, New York, NY 10031 USA
来源
ADVANCED ENVIRONMENTAL, CHEMICAL, AND BIOLOGICAL SENSING TECHNOLOGIES X | 2013年 / 8718卷
关键词
Laser sensors; air pollution monitoring; quantum cascade laser; trace gases; SPECTROMETER;
D O I
10.1117/12.2016294
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Quantum Cascade Lasers (QCL's) have been successfully used to monitor atmospheric pollutants in the mid-infrared (mid-IR) region. However, their use for multiple gases in ambient conditions is less familiar. This paper explores the performance of a novel field deployable open path system based on a chirped single distributed-feedback QCL. In particular, we report both laboratory and open path measurements for simultaneous detection of two greenhouse gases (GHG) methane (CH4) and nitrous oxide. (N2O). We focused on CH4 and N2O because they are long-lived greenhouse gases in the atmosphere with significant global warming effects. Gas spectra were recorded by tuning the QC laser wavelength using a thermal down chirp technique over 1297-1300 cm(-1) optimal spectral window with 0.008 cm(-1) spectral resolution. Based on careful optimization of the spectral window for absorption features of CH4 and N2O, a dual-species, cost-effective, robust and rapid response open-path laser based monitor has been developed for ambient trace gas monitoring. Theoretical signal to noise ratio (SNR) analysis of the system based on an ideal system is briefly discussed in the paper but our main focus is on actual system performance, long term stability and systemic errors. Finally, preliminary results of the open path system are reported
引用
收藏
页数:12
相关论文
共 11 条
[1]  
[Anonymous], 2007, IPCC Fourth Assessment Report
[2]  
Forster P, 2007, AR4 CLIMATE CHANGE 2007: THE PHYSICAL SCIENCE BASIS, P129
[3]   Chemical sensors based on quantum cascade lasers [J].
Kosterev, AA ;
Tittel, FK .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 2002, 38 (06) :582-591
[4]  
LaCosse Jeffrey P., 320 EPA SPECTR INS L
[5]   Measurements of ambient ammonia using a tunable diode laser absorption spectrometer: Characteristics of ambient ammonia emissions in an urban area of New York City [J].
Li, Yongquan ;
Schwab, James J. ;
Demerjian, Kenneth L. .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2006, 111 (D10)
[6]  
Maung Thet L., 2010, THESIS CITY COLL NEW
[7]   Fast, real-time spectrometer based on a pulsed quantum-cascade laser [J].
Normand, E ;
McCulloch, M ;
Duxbury, G ;
Langford, N .
OPTICS LETTERS, 2003, 28 (01) :16-18
[8]  
Prokes A, 2009, ATMOSPHERIC EFFECTS
[9]   The HITRAN molecular spectroscopic database: edition of 2000 including updates through 2001 [J].
Rothman, LS ;
Barbe, A ;
Benner, DC ;
Brown, LR ;
Camy-Peyret, C ;
Carleer, MR ;
Chance, K ;
Clerbaux, C ;
Dana, V ;
Devi, VM ;
Fayt, A ;
Flaud, JM ;
Gamache, RR ;
Goldman, A ;
Jacquemart, D ;
Jucks, KW ;
Lafferty, WJ ;
Mandin, JY ;
Massie, ST ;
Nemtchinov, V ;
Newnham, DA ;
Perrin, A ;
Rinsland, CP ;
Schroeder, J ;
Smith, KM ;
Smith, MAH ;
Tang, K ;
Toth, RA ;
Vander Auwera, J ;
Varanasi, P ;
Yoshino, K .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2003, 82 (1-4) :5-44
[10]   Open-path ozone detection by quantum-cascade laser [J].
Taslakov, M ;
Simeonov, V ;
Froidevaux, M ;
van den Bergh, H .
APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 82 (03) :501-506