Efficient optimal design and design-under-uncertainty of passive control devices with application to a cable-stayed bridge

被引:15
|
作者
De, Subhayan [1 ]
Wojtkiewicz, Steven F. [2 ]
Johnson, Erik A. [1 ]
机构
[1] Univ Southern Calif, Sonny Astani Dept Civil & Environm Engn, Los Angeles, CA 90089 USA
[2] Clarkson Univ, Dept Civil & Environm Engn, Potsdam, NY 13699 USA
基金
美国国家科学基金会;
关键词
passive structural control; design under uncertainty; optimal design; cable-stayed bridge; Volterra integral equation; TUNED MASS DAMPERS; RELIABILITY-BASED OPTIMIZATION; OPTIMAL PLACEMENT; STRUCTURAL OPTIMIZATION; SEISMIC APPLICATIONS; ABSORBER PARAMETERS; RESPONSE CONTROL; TRUSS STRUCTURES; VISCOUS DAMPERS; CONTROL-SYSTEMS;
D O I
10.1002/stc.1846
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Structures today may be equipped with passive structural control devices to achieve some performance criteria. The optimal design of these passive control devices, whether via a formal optimization algorithm or a response surface parameter study, requires multiple solutions of the dynamic response of that structure, incurring a significant computational cost for complex structures. These passive control elements are typically point-located, introducing a local change (possibly nonlinear, possibly uncertain) that affects the global behavior of the rest of the structure. When the structure, other than these localized devices, is linear and deterministic, conventional solvers (e.g., Runge-Kutta, MATLAB's ode45, etc.) ignore the localized nature of the passive control elements. The methodology applied in this paper exploits the locality of the uncertain and/ or nonlinear passive control element(s) by exactly converting the form of the dynamics of the high-order structural model to a low-dimensional Volterra integral equation. Design optimization for parameters and placement of linear and nonlinear passive dampers, tuned mass dampers, and their combination, as well as their design-under-uncertainty for a benchmark cable-stayed bridge, is performed using this approach. For the examples considered herein, the proposed method achieves a two-orders-of-magnitude gain in computational efficiency compared with a conventional method of comparable accuracy. Copyright (C) 2016 John Wiley & Sons, Ltd.
引用
收藏
页数:20
相关论文
共 47 条
  • [21] The Design and Study on Long-Span Road-Rail Cable-Stayed Bridge
    Zhang, Xianqing
    Guo, Shulun
    Lei, Junqing
    6TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND CIVIL ENGINEERING, 2020, 455
  • [22] Fail-safe optimum cable system under cable breakage in cable-stayed bridges. Application to the Queensferry Crossing Bridge
    Soto, Noel
    Cid, Clara
    Baldomir, Aitor
    Hernandez, Santiago
    ENGINEERING STRUCTURES, 2023, 279
  • [23] Simplified seismic resistant design of base isolated single pylon cable-stayed bridge
    Qiang Han
    Jianian Wen
    Xiuli Du
    Zilan Zhong
    Hong Hao
    Bulletin of Earthquake Engineering, 2018, 16 : 5041 - 5059
  • [24] Optimization Design of Large Span Cable-Stayed Bridge in High Seismic Risk Zone
    Xiong Zhihua
    Feng Yuncheng
    Song Songlin
    Wang Jiangbo
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING, PTS 1-4, 2013, 353-356 : 2015 - 2019
  • [25] THE STRUCTURE DESIGN AND CONSTRUCTION FEATURE OF CONCRETE INCLINED PYLON CABLE-STAYED BRIDGE WITH BACKSTAYS
    Jiang, De-Zeng
    Wang, Rong-Hui
    Ma, Niu-Jing
    ISISS '2009: INNOVATION & SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2009, : 919 - 924
  • [26] Seismic Design of a Long-Span Cable-Stayed Bridge with Fluid Viscous Dampers
    Zhu, Jin
    Zhang, Wei
    Zheng, K. F.
    Li, H. G.
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2016, 21 (01)
  • [27] Seismic design of a steel-concrete hybrid cable-stayed bridge - the Shin-Minato bridge
    Yoshinaga, Hiroshi
    Ymanouchi, Tetsuya
    Goto, Yoshio
    Nagai, Masatsugu
    STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2008, 1 (01): : 66 - U124
  • [28] Simplified seismic resistant design of base isolated single pylon cable-stayed bridge
    Han, Qiang
    Wen, Jianian
    Du, Xiuli
    Zhong, Zilan
    Hao, Hong
    BULLETIN OF EARTHQUAKE ENGINEERING, 2018, 16 (10) : 5041 - 5059
  • [29] Parameter Design for Viscous Dampers to Near-fault Cable-stayed Bridge Based on Equivalent Damping Ratio
    Huang, Yongfu
    Xu, Yan
    Li, Jianzhong
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON MATERIALS, ENVIRONMENTAL AND BIOLOGICAL ENGINEERING, 2015, 10 : 612 - 617
  • [30] Efficient optimal design of passive structural control applied to isolator design
    Kamalzare, Mahmoud
    Johnson, Erik A.
    Wojtkiewicz, Steven F.
    SMART STRUCTURES AND SYSTEMS, 2015, 15 (03) : 847 - 862