Improvement of the Embalming Perfusion Method: The Innovation and the Results by Light and Scanning Electron Microscopy

被引:0
作者
Goyri-O'Neill, Joao [1 ,7 ]
Pais, Diogo [2 ,3 ]
de Andrade, Francisco Freire [4 ]
Ribeiro, Paulo [5 ]
Belo, Ana [6 ]
O'Neill, Assuncao [4 ]
Ramos, Samuel [1 ]
Marques, Claudia Neves [1 ]
机构
[1] Univ Nova Lisboa, Fac Ciencias Med, Dept Anat, P-1200 Lisbon, Portugal
[2] Univ Nova Lisboa, Fac Ciencias Med, Dept Anat, P-1200 Lisbon, Portugal
[3] Univ Nova Lisboa, Fac Ciencias Med, Body Donat Off, P-1200 Lisbon, Portugal
[4] Univ Nova Lisboa, Fac Ciencias Med, P-1200 Lisbon, Portugal
[5] Univ Nova Lisboa, Fac Ciencias & Tecnol, Dept Phys, P-1200 Lisbon, Portugal
[6] Alfredo Costa Matern, Dept Pathol, Lisbon, Portugal
[7] CEFITEC, Phys & Technol Invest Ctr, Lisbon, Portugal
关键词
Embalming; Dissection; Cadaver; Solutions; Microscopy; Electron; Scanning; GOVERNING BODY DONATION; GROSS-ANATOMY; FORMALDEHYDE EXPOSURE; COMPLETE CADAVERS; PRESERVATION; DISSECTION; PHENOXYETHANOL; CONSEQUENCES; EUROPE; MODELS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Embalming is a chemical process that aims the preservation and sanitization of the human body indefinitely. The technique of embalming is an important tool in teaching and research in anatomy enabling the preservation of cadaveric material in good conditions (lessening any significant structural changes and maintaining the natural appearance). This article presents the results of embalmed cadavers in the course of arterial perfusion, through the use of a perfusion machine, particularly designed to this objective, and which allows the control of the embalming fluid injection process. The influence of this technique and the optimization of its parameters on the final quality of embalming were evaluated by sequential histological analysis of the cadaveric tissues using an original method of classification of samples collected from 17 deceased corpses of the Corpses Donation Office of the Department of Anatomy of Faculdade de Ciencias Medicas from Universidade Nova de Lisboa, subject to the embalming technique developed in the Department. We concluded that, with this method, there is a decrease of the decomposition process at the time of embalming, which is effective at long term (over a year), requiring merely the maintenance of the body at low temperatures (4 degrees C) and it is possible to observe that the tissue best preserved over time is muscle, showing a conservation considered optimal.
引用
收藏
页码:188 / 194
页数:7
相关论文
共 32 条
[1]  
[Anonymous], 1991, PAR UT CAD HUM FINS, V1, P67
[2]   Comparison of fresh and Thiel's embalmed cadavers according to the suitability for ultrasound-guided regional anesthesia of the cervical region [J].
Benkhadra, Mehdi ;
Faust, Alexandre ;
Ladoire, Sylvain ;
Trost, Olivier ;
Trouilloud, Pierre ;
Girard, Claude ;
Anderhuber, Friedrich ;
Feigl, Georg .
SURGICAL AND RADIOLOGIC ANATOMY, 2009, 31 (07) :531-535
[3]  
BRADBURY SA, 1978, ACTA ANAT, V101, P97
[4]   Fomepizole for the treatment of ethylene glycol poisoning [J].
Brent, J ;
McMartin, K ;
Phillips, S ;
Burkhart, KK ;
Donovan, JW ;
Wells, M ;
Kulig, K .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (11) :832-838
[5]   An improved low-formaldehyde embalming fluid to preserve cadavers for anatomy teaching [J].
Coleman, R ;
Kogan, I .
JOURNAL OF ANATOMY, 1998, 192 :443-446
[6]   REDUCING THE LEVELS OF FORMALDEHYDE EXPOSURE IN GROSS-ANATOMY LABORATORIES [J].
COLEMAN, R .
ANATOMICAL RECORD, 1995, 243 (04) :531-533
[7]  
Esperanca-Pina J., 1983, Acta Medica Portuguesa, V4, P433
[8]   CONSEQUENCES OF ETHYLENE GLYCOL POISONING - REPORT OF 4 CASES AND REVIEW OF LITERATURE [J].
FRIEDMAN, EA ;
DAMMIN, GJ ;
MERRILL, JP ;
GREENBERG, JB .
AMERICAN JOURNAL OF MEDICINE, 1962, 32 (06) :891-+
[9]   PHENOXYETHANOL AS A NONTOXIC SUBSTITUTE FOR FORMALDEHYDE IN LONG-TERM PRESERVATION OF HUMAN ANATOMICAL SPECIMENS FOR DISSECTION AND DEMONSTRATION PURPOSES [J].
FROLICH, KW ;
ANDERSEN, LM ;
KNUTSEN, A ;
FLOOD, PR .
ANATOMICAL RECORD, 1984, 208 (02) :271-278
[10]   Blood flow simulation through fractal models of circulatory system [J].
Gabrys, E ;
Rybaczuk, M ;
Kedzia, A .
CHAOS SOLITONS & FRACTALS, 2006, 27 (01) :1-7