Study of electrochemical corrosion of biocompatible Co-Cr and Ni-Cr dental alloys in artificial saliva. Influence of pH of the solution

被引:28
作者
Turdean, Graziella L. [1 ]
Craciun, Antarinia [2 ]
Popa, Daniela [2 ]
Constantiniuc, Mariana [2 ]
机构
[1] Babes Bolyai Univ, Fac Chem & Chem Engn, Chem Engn Dept, Res Ctr Electrochem & Nonconvent Mat, 11 Arany Janos St, Cluj Napoca, Romania
[2] Iuliu Hatieganu Univ Med & Pharm, Fac Med Dent, 8 Victor Babes St, Cluj Napoca, Romania
关键词
Biomaterials; Corrosion; Electrochemical impedance spectroscopy; BINARY-ALLOYS; BEHAVIOR; RESISTANCE; FLUORIDE; MO; TRIBOCORROSION;
D O I
10.1016/j.matchemphys.2019.05.041
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The pH of saliva is changeable and variable in the oral environment in function of the quality of foods and liquids ingested. Also, the biocompatibility of a material for dental applications is checked not only by clinical and epidemiological studies, but also by corrosion resistance studies. The aim of this study was to investigate the influence of the pH value of artificial saliva on the corrosion of the Co-Cr and Ni-Cr dental alloys, using different electrochemical techniques such as: cyclic voltammetry, open circuit potential (OCP) measurement, polarization curves and electrochemical impedance spectroscopy (EIS). The obtained results are complementary with scanning electron microscopy (SEM) coupled with energy-dispersive X-ray spectroscopy (EDXS) analysis, proving that Co-Cr alloy is more resistant in time, and recommending it for successful treatment of patients with dental prosthesis having metal frameworks.
引用
收藏
页码:390 / 398
页数:9
相关论文
共 41 条
[1]   Electrochemical behaviour of recasting Ni-Cr and Co-Cr non-precious dental alloys [J].
Ameer, MA ;
Khamis, E ;
Al-Motlaq, M .
CORROSION SCIENCE, 2004, 46 (11) :2825-2836
[2]   Corrosion and surface modification on biocompatible metals: A review [J].
Asri, R. I. M. ;
Harun, W. S. W. ;
Samykano, M. ;
Lah, N. A. C. ;
Ghani, S. A. C. ;
Tarlochan, F. ;
Raza, M. R. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 77 :1261-1274
[3]   Electrochemical corrosion of Ti-Al2O3 biocomposites in Ringer's solution [J].
Bahraminasab, Marjan ;
Bozorg, Mansoor ;
Ghaffari, Somaye ;
Kavakebian, Fatemeh .
JOURNAL OF ALLOYS AND COMPOUNDS, 2019, 777 :34-43
[4]   Combined Effects of pH and γ-Irradiation on the Corrosion of Co-Cr Alloy Stellite-6 [J].
Behazin, M. ;
Noel, J. J. ;
Wren, J. C. .
ELECTROCHIMICA ACTA, 2014, 134 :399-410
[5]  
Bergmann C.P., 2013, Dental Ceramics - Microstructure, Properties and Degradation (Topics in Mining, Metallurgy and Materials Engineering Series), P9, DOI [DOI 10.1007/978-3-642-38224-6_2, 10.1007/ 978-3-642-38224-6, DOI 10.1007/978-3-642-38224-6, 10.1007/978-3-642-38224-6_2]
[6]  
Fort CI., 2019, STUDIA UBB CHEM, V64, P125
[7]   Influence of the casting processing route on the corrosion behavior of dental alloys [J].
Galo, Rodrigo ;
Rocha, Luis Augusto ;
Faria, Adriana Claudia ;
Silveira, Renata Rodrigues ;
Ribeiro, Ricardo Faria ;
Chiarello de Mattos, Maria da Gloria .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 45 :519-523
[8]  
Galo Rodrigo, 2012, Braz. Dent. J., V23, P141
[9]   Influence of fluoride content and pH on corrosion and tribocorrosion behaviour of Ti13Nb13Zr alloy in oral environment [J].
Golvano, I. ;
Garcia, I. ;
Conde, A. ;
Tato, W. ;
Aginagalde, A. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2015, 49 :186-196
[10]  
Hansen D. C., 2008, INTERFACE SUMMER, P31