Is Optical Coherence Tomography a Potential Tool to Evaluate Marginal Adaptation of Class III/IV Composite Restorations In Vivo?

被引:16
|
作者
Schneider, H. [1 ]
Steigerwald-Otremba, A. S. [1 ]
Hafer, M. [1 ]
Krause, F. [1 ]
Scholz, M. [2 ]
Haak, R. [1 ]
机构
[1] Univ Leipzig, Dept Cariol Endodontol & Periodontol, Leipzig, Germany
[2] Univ Leipzig, Inst Med Informat Stat & Epidemiol, Leipzig, Germany
关键词
SELF-ETCH; BOND STRENGTH; INTEGRITY; QUALITY; MICROLEAKAGE; INTERFACE; BREAKDOWN; TESTS; SEM; OCT;
D O I
10.2341/17-192-C
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: Margin analysis of Class III and IV composite restorations in vitro and in vivo occurred by scanning electron microscopy (SEM) and optical coherence tomography (OCT). The results were compared and related to clinical evaluation. Methods and Materials: Eight Class III composite restorations were imaged in vitro using OCT and SEM. The margins were analyzed quantitatively. OCT signals were verified by assignment to the criteria perfect margin, gap, and positive/negative ledge. In vivo quantitative margin analysis of Class III/IV composite restorations made of the micro-hybrid composite Venus combined with the self-etch adhesive iBond Gluma inside (1-SE) or etchand-rinse adhesive Gluma Comfort Bond (2-ER) (all Heraeus Kulzer) was carried out using OCT and SEM after 90 months of clinical function. The results were compared with clinical evaluation (US Public Health Service criteria; marginal integrity, marginal discoloration). Results: In vitro, the correlation between OCT and SEM was high for all four margin criteria (Kendall tau b [tau(b)] correlation: 0.64-0.92, p(i)<= 0.026), with no significant differences between OCT and SEM (p(i)>= 0.63). In vivo, a moderate correlation was observed (tau(b): 0.38-0.45, p(i)<0.016). Clinically, the cumulative failure rate in the criterion marginal integrity was higher for the 1-SE group (baseline 90 M, p=0.011). Similarly, OCT and SEM detected higher percentages of the criterion gap in the 1-SE group (p: 0.027/0.002), in contrast to perfect margin. Both, gap and perfect margin ranged widely between 0.0% and 88.7% (OCT) and between 0.0% and 89.0% (SEM). Conclusion: Despite the positive selection bias after 90 months with only a few patients left, quantitative margin analysis allows for differentiation between the two adhesives at this specific date. OCT in particular offers the possibility to evaluate marginal integrity directly in vivo.
引用
收藏
页码:242 / 253
页数:12
相关论文
共 24 条
  • [21] In vivo comparison of a microfilled and a hybrid minifilled composite resin in Class III restorations: 2-year follow-up.
    Reusens B.
    D'hoore W.
    Vreven J.
    Clinical Oral Investigations, 1999, 3 (2) : 62 - 69
  • [22] Selective Enamel Etching: Effect on Marginal Adaptation of Self-Etch LED-Cured Bond Systems in Aged Class I Composite Restorations
    Souza-Junior, E. J.
    Prieto, L. T.
    Araujo, C. T. P.
    Paulillo, L. A. M. A.
    OPERATIVE DENTISTRY, 2012, 37 (02) : 195 - 204
  • [23] Potential use of optical coherence tomography in oral potentially malignant disorders: in-vivo case series study
    Gambino, Alessio
    Martina, Eugenio
    Panzarella, Vera
    Ruggiero, Tiziana
    El Haddad, Giorgia
    Broccoletti, Roberto
    Arduino, Paolo G.
    BMC ORAL HEALTH, 2023, 23 (01)
  • [24] Potential New Diagnostic Tool for Alzheimer's Disease Using a Linear Discriminant Function for Fourier Domain Optical Coherence Tomography
    Larrosa, Jose M.
    Garcia-Martin, Elena
    Bambo, Maria P.
    Pinilla, Juan
    Polo, Vicente
    Otin, Sofia
    Satue, Maria
    Herrero, Raquel
    Pablo, Luis E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (05) : 3043 - 3051