Myocardial and microcirculatory kinetics of BR14, a novel third-generation intravenous ultrasound contrast agent
被引:39
作者:
Fisher, NG
论文数: 0引用数: 0
h-index: 0
机构:
Univ Virginia, Med Ctr, Div Cardiovasc, Cardiovasc Imaging Ctr, Charlottesville, VA 22908 USAUniv Virginia, Med Ctr, Div Cardiovasc, Cardiovasc Imaging Ctr, Charlottesville, VA 22908 USA
Fisher, NG
[1
]
Christiansen, JP
论文数: 0引用数: 0
h-index: 0
机构:
Univ Virginia, Med Ctr, Div Cardiovasc, Cardiovasc Imaging Ctr, Charlottesville, VA 22908 USAUniv Virginia, Med Ctr, Div Cardiovasc, Cardiovasc Imaging Ctr, Charlottesville, VA 22908 USA
Christiansen, JP
[1
]
Leong-Poi, H
论文数: 0引用数: 0
h-index: 0
机构:
Univ Virginia, Med Ctr, Div Cardiovasc, Cardiovasc Imaging Ctr, Charlottesville, VA 22908 USAUniv Virginia, Med Ctr, Div Cardiovasc, Cardiovasc Imaging Ctr, Charlottesville, VA 22908 USA
Leong-Poi, H
[1
]
Jayaweera, AR
论文数: 0引用数: 0
h-index: 0
机构:
Univ Virginia, Med Ctr, Div Cardiovasc, Cardiovasc Imaging Ctr, Charlottesville, VA 22908 USAUniv Virginia, Med Ctr, Div Cardiovasc, Cardiovasc Imaging Ctr, Charlottesville, VA 22908 USA
Jayaweera, AR
[1
]
Lindner, JR
论文数: 0引用数: 0
h-index: 0
机构:
Univ Virginia, Med Ctr, Div Cardiovasc, Cardiovasc Imaging Ctr, Charlottesville, VA 22908 USAUniv Virginia, Med Ctr, Div Cardiovasc, Cardiovasc Imaging Ctr, Charlottesville, VA 22908 USA
Lindner, JR
[1
]
Kaul, S
论文数: 0引用数: 0
h-index: 0
机构:
Univ Virginia, Med Ctr, Div Cardiovasc, Cardiovasc Imaging Ctr, Charlottesville, VA 22908 USAUniv Virginia, Med Ctr, Div Cardiovasc, Cardiovasc Imaging Ctr, Charlottesville, VA 22908 USA
Kaul, S
[1
]
机构:
[1] Univ Virginia, Med Ctr, Div Cardiovasc, Cardiovasc Imaging Ctr, Charlottesville, VA 22908 USA
OBJECTIVES This study sought to investigate the myocardial and microvascular kinetics of BR14, a novel third-generation ultrasound contrast agent. BACKGROUND BR14 produces persistent myocardial opacification after the administration of a single intravenous bolus when the left ventricular cavity contrast has considerably diminished. The mechanism of this finding is unknown. METHODS Nine open-chest dogs with non-critical stenosis of a single coronary artery were given intravenous bolus injections of BR14 during coronary hyperemia. Time versus acoustic intensity (AI) plots were generated from the normal and stenosed beds and myocardial blood flow (MBF) was measured with radiolabeled microspheres. Intravital microscopy was performed on an exteriorized cremaster muscle in 11 wild-type mice to study the microvascular kinetics of the agent. RESULTS At peak contrast enhancement, the ratio between AI in the stenosed and normal bed was 0.44 +/- 0.23, which was similar to the radiolabeled microsphere-derived MBF ratio between the two beds (0.45 +/- 0.20). At 400 s after injection, the AI ratio between the two beds approximated unity (0.99 +/- 0.07) despite no changes in MBF, indicating redistribution of the agent. The myocardial kinetics of BR14 was best characterized by a modified lagged normal density function. Only about 3% of administered microbubbles were estimated to be retained in the myocardium. Intravital microscopy showed that most of these bubbles were retained only transiently (2 to 3 s) within capillaries. CONCLUSIONS BR14 demonstrates redistribution because of transient retention within capillaries. Therefore, similar to Tl-201, it could potentially be used to detect both coronary stenosis and myocardial viability after a single injection during stress. (C) 2002 by the American College of Cardiology.