E.A.O. guidelines for the use of diagnostic imaging in implant dentistry 2011. A consensus workshop organized by the European Association for Osseointegration at the Medical University of Warsaw

被引:233
作者
Harris, David [1 ]
Horner, Keith [2 ]
Grondahl, Kerstin [3 ]
Jacobs, Reinhilde [4 ]
Helmrot, Ebba [3 ]
Benic, Goran I. [5 ]
Bornstein, Michael M. [6 ]
Dawood, Andrew [7 ]
Quirynen, Marc [8 ]
机构
[1] Trinity Coll Dublin, Dublin Dent Sch & Hosp, Dublin 2, Ireland
[2] Univ Manchester, Sch Dent, Manchester, Lancs, England
[3] Inst Postgrad Dent Educ, Dept Dentomaxillofacial Radiol, Jonkoping, Sweden
[4] Katholieke Univ Leuven, Sch Dent Oral Pathol & Maxillofacial Surg, Oral Imaging Ctr, Louvain, Belgium
[5] Univ Zurich, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Ctr Dent Med, Zurich, Switzerland
[6] Univ Bern, Sch Dent Med, Dept Oral Surg & Stomatol, Bern, Switzerland
[7] Cavendish Imaging, London, England
[8] Katholieke Univ Leuven, Dept Periodontol, Sch Dent Oral Pathol & Maxillofacial Surg, Louvain, Belgium
关键词
anatomical boundaries; clinical assessment; CT imaging; dental implants; diagnostic imaging; imaging; justification; optimization; patient selection; periodontology; practice guideline; prosthodontics; radiation dosimetry; radiology; sinus floor elevation; BEAM COMPUTED-TOMOGRAPHY; DIFFERENT FIELDS; 3D ACCUITOMO; CBCT DEVICES; DOSIMETRY; QUALITY; CT; SCANNERS; IMPACT;
D O I
10.1111/j.1600-0501.2012.02441.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Diagnostics imaging is an essential component of patient selection and treatment planning in oral rehabilitation by means of osseointegrated implants. In 2002, the EAO produced and published guidelines on the use of diagnostic imaging in implant dentistry. Since that time, there have been significant developments in both the application of cone beam computed tomography as well as in the range of surgical and prosthetic applications that can potentially benefit from its use. However, medical exposure to ionizing radiation must always be justified and result in a net benefit to the patient. The as low a dose as is reasonably achievable principle must also be applied taking into account any alternative techniques that might achieve the same objectives. This paper reports on current EAO recommendations arising from a consensus meeting held at the Medical University of Warsaw (2011) to update these guidelines. Radiological considerations are detailed, including justification and optimization, with a special emphasis on the obligations that arise for those who prescribe or undertake such investigations. The paper pays special attention to clinical indications and radiographic diagnostic considerations as well as to future developments and trends.
引用
收藏
页码:1243 / 1253
页数:11
相关论文
共 38 条
  • [31] Effective dose from cone beam CT examinations in dentistry
    Roberts, J. A.
    Drage, N. A.
    Davies, J.
    Thomas, D. W.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (973) : 35 - 40
  • [32] SEDENTEXCT, 2011, RAD PROT CON BEAM CT
  • [33] Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners
    Suomalainen, A.
    Kiljunen, T.
    Kaser, Y.
    Peltola, J.
    Kortesniemi, M.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (06) : 367 - 378
  • [34] Are panoramic images reliable in planning sinus augmentation procedures?
    Temmerman, Andy
    Hertele, Stijn
    Teughels, Wim
    Dekeyser, Christel
    Jacobs, Reinhilde
    Quirynen, Marc
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (02) : 189 - 194
  • [35] Methods of determining the effective dose in dental radiology
    Thilander-Klang, Anne
    Helmrot, Ebba
    [J]. RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 306 - 309
  • [36] UNSCEAR, 2010, SOURC EFF ION RAD UN, VI
  • [37] The relative impact of local and endogenous patient-related factors on implant failure up to the abutment stage
    van Steenberghe, D
    Facobs, R
    Desnyder, M
    Maffei, G
    Quirynen, M
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (06) : 617 - 622
  • [38] The use of CT scan based planning for oral rehabilitation by means of implants and its transfer to the surgical field: a critical review on accuracy
    Vercruyssen, M.
    Jacobs, R.
    Van Assche, N.
    Van Steenberghe, D.
    [J]. JOURNAL OF ORAL REHABILITATION, 2008, 35 (06) : 454 - 474