Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit - A pilot study

被引:181
|
作者
Aarts, Lonneke A. M. [1 ]
Jeanne, Vincent [2 ]
Cleary, John P. [3 ]
Lieber, C. [3 ]
Nelson, J. Stuart [4 ]
Oetomo, Sidarto Bambang [1 ]
Verkruysse, Wim [2 ,4 ]
机构
[1] Maxima Med Ctr, Dept Pediat, Veldhoven, Netherlands
[2] Philips Res, Eindhoven, Netherlands
[3] Childrens Hosp Orange Cty, Orange, CA 92668 USA
[4] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA USA
关键词
Unobtrusive; Remote; Contactless; Vital signs; Premature infant; Skin damage; Contact sensor; Pulse oximetry; PPG; Newborn; Mother-child bonding; Ambient light;
D O I
10.1016/j.earlhumdev.2013.09.016
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background: Presently the heart rate is monitored in the Neonatal Intensive Care Unit with contact sensors: electrocardiogram or pulse oximetry. These techniques can cause injuries and infections, particularly in very premature infants with fragile skin. Camera based plethysmography was recently demonstrated in adults as a contactless method to determine heart rate. Aim: To investigate the feasibility of this technique for NICU patients and identify challenging conditions. Study design and participants: Video recordings using only ambient light were made of 19 infants at two NICUs in California and The Netherlands. Heart rate can be derived from these recordings because each cardiovascular pulse wave induces minute pulsatile skin color changes, invisible to the eye but measurable with a camera. Results: In all infants the heart beat induced photoplethysmographic signal was strong enough to be measured. Low ambient light level and infant motion prevented successful measurement from time to time. Conclusions: Contactless heart rate monitoring by means of a camera using ambient light was demonstrated for the first time in the NICU population and appears feasible. Better hardware and improved algorithms are required to increase robustness. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:943 / 948
页数:6
相关论文
共 18 条
  • [1] Non-Contact, Simple Neonatal Monitoring by Photoplethysmography
    Cobos-Torres, Juan-Carlos
    Abderrahim, Mohamed
    Martinez-Orgado, Jose
    SENSORS, 2018, 18 (12)
  • [2] A Non-Contact Photoplethysmography Technique for the Estimation of Heart Rate via Smartphone
    Maestre-Rendon, J. Rodolfo
    Rivera-Roman, Tomas A.
    Fernandez-Jaramillo, Arturo A.
    Guerron Paredes, Nancy E.
    Serrano Olmedo, Jose Javier
    APPLIED SCIENCES-BASEL, 2020, 10 (01):
  • [3] Non-contact physiological monitoring of post-operative patients in the intensive care unit
    Jorge, Joao
    Villarroel, Mauricio
    Tomlinson, Hamish
    Gibson, Oliver
    Darbyshire, Julie L.
    Ede, Jody
    Harford, Mirae
    Young, John Duncan
    Tarassenko, Lionel
    Watkinson, Peter
    NPJ DIGITAL MEDICINE, 2022, 5 (01)
  • [4] A Machine Learning Method to Improve Non-Contact Heart Rate Monitoring Using an RGB Camera
    Ghanadian, Hamideh
    Ghodratigohar, Mohammad
    Al Osman, Hussein
    IEEE ACCESS, 2018, 6 : 57085 - 57094
  • [5] Forehead monitoring of heart rate in neonatal intensive care
    Stockwell, S. J.
    Kwok, T. C.
    Morgan, S. P.
    Sharkey, D.
    Hayes-Gill, B. R.
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [6] Comparison of non-contact infrared forehead thermometer to standard temperature measurement in neonatal intensive care unit patients
    Can, Emrah
    Bulbul, Ali
    Uslu, Sinan
    Nuhoglu, Asiye
    TURK PEDIATRI ARSIVI-TURKISH ARCHIVES OF PEDIATRICS, 2010, 45 (03): : 257 - 263
  • [7] A neonatal dataset and benchmark for non-contact neonatal heart rate monitoring based on spatio-temporal neural networks
    Huang, Bin
    Chen, Weihai
    Lin, Chun-Liang
    Juang, Chia-Feng
    Xing, Yuanping
    Wang, Yanting
    Wang, Jianhua
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2021, 106
  • [8] Accuracy of pulse oximetry in assessing heart rate of infants in the neonatal intensive care unit
    Singh, Jasbir K. S. B.
    Kamlin, C. Omar F.
    Morley, Colin J.
    O'Donnell, Colm P. F.
    Donath, Susan M.
    Davis, Peter G.
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2008, 44 (05) : 273 - 275
  • [9] Non-contact sensing of neonatal pulse rate using camera-based imaging: a clinical feasibility study
    Paul, M.
    Karthik, S.
    Joseph, J.
    Sivaprakasam, M.
    Kumutha, J.
    Leonhardt, S.
    Antink, C. Hoog
    PHYSIOLOGICAL MEASUREMENT, 2020, 41 (02)
  • [10] Development of a baby friendly non-contact method for measuring vital signs: first results of clinical measurements in an open incubator at a Neonatal Intensive Care Unit
    Klaessens, John H. G. M.
    van den Born, Marlies
    van der Veen, Albert
    Sikkens-van de Kraats, Janine
    van den Dungen, Frank A. M.
    Verdaasdonk, Rudolf M.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XII, 2014, 8935