Total hip arthroplasty in young patients. Bearings and custom-made prostheses

被引:0
作者
Benignus, C. [1 ]
Morlock, M. [2 ]
Beckmann, J. [1 ]
机构
[1] Sportklin Stuttgart GmbH, Taubenheimstr 8, D-70372 Stuttgart, Germany
[2] TUHH Tech Univ Hamburg, Inst Biomech, Hamburg, Germany
来源
ORTHOPADE | 2019年 / 48卷 / 04期
关键词
THA; Wear; Corrosion; Tribology; CERAMIC-ON-METAL; CROSS-LINKED POLYETHYLENE; ION LEVELS; FOLLOW-UP; HEADS DECREASE; REVISION RATES; FEMORAL HEADS; WEAR RATES; REPLACEMENT; IMPLANT;
D O I
10.1007/s00132-019-03692-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundCarefully and correctly implanted components are the prerequisite for the lifespan of aprosthesis. Whether higher levels of activity lead to prior failure of total hip arthroplasty in young patients is controversially discussed. The right choice of bearings is still of great relevance.BearingsCeramic-on-ceramic as well as polyethylene-on-ceramic bearings achieve comparable results, although ceramic-on-ceramic bearings should be avoided in patients with high demands on their range of motion. Polyethylene-on-metal bearings also show good clinical results, if corrosion between head and stem is absent. Metal-on-metal bearings lead to adverse systemic effects due to metal wear and should be implanted in individual cases only, e.g. as hip resurfacing. Alternative bearings have to give proof of effectivity first. Custom-made prostheses constitute an option for young patients with special conditions of hip anatomy. Planning and study results of these prostheses are elucidated in this review article.
引用
收藏
页码:292 / 299
页数:8
相关论文
共 60 条
  • [1] Fractures of a Single Design of Highly Cross-Linked Polyethylene Acetabular Liners: An Analysis of Voluntary Reports to the United States Food and Drug Administration
    Ast, Michael P.
    John, Thomas K.
    Labbisiere, Anthony
    Robador, Nicolas
    Della Valle, Alejandro Gonzalez
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (06) : 1231 - 1235
  • [2] Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty
    Bernstein, Mitchell
    Desy, Nicholas M.
    Petit, Alain
    Zukor, David J.
    Huk, Olga L.
    Antoniou, John
    [J]. INTERNATIONAL ORTHOPAEDICS, 2012, 36 (09) : 1807 - 1812
  • [3] Bongaerts G, 2009, UNFALLCHIRURG S1, V112, P13
  • [4] High incidence of pseudotumour formation after large-diameter metal-on-metal total hip replacement A PROSPECTIVE COHORT STUDY
    Bosker, B. H.
    Ettema, H. B.
    Boomsma, M. F.
    Kollen, B. J.
    Maas, M.
    Verheyen, C. C. P. M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (06): : 755 - 761
  • [5] Ultra-High Molecular Weight Polyethylene: Influence of the Chemical, Physical and Mechanical Properties on the Wear Behavior. A Review
    Bracco, Pierangiola
    Bellare, Anuj
    Bistolfi, Alessandro
    Affatato, Saverio
    [J]. MATERIALS, 2017, 10 (07)
  • [6] Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements
    Clarke, IC
    Good, V
    Williams, P
    Schroeder, D
    Anissian, L
    Stark, A
    Oonishi, H
    Schuldies, J
    Gustafson, G
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H4) : 331 - 347
  • [7] Less wear with aluminium-oxide heads than cobalt-chrome heads with ultra high molecular weight cemented polyethylene cups: A ten-year follow-up with radiostereometry
    Dahl, Jon
    Soderlund, Per
    Nivbrant, Bo
    Nordsletten, Lars
    Rohrl, Stephan M.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2012, 36 (03) : 485 - 490
  • [8] Is there any range-of-motion advantage to using bearings larger than 36 mm in primary hip arthroplasty: A case-control study comparing 36-mm and large-diameter heads
    Delay, C.
    Putman, S.
    Dereudre, G.
    Girard, J.
    Lancelier-Bariatinsky, V.
    Drumez, E.
    Migaud, H.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (06) : 735 - 740
  • [9] Rapid prototyping technique in the preoperative planning for total hip arthroplasty with custom femoral components
    Faur, Cosmin
    Crainic, Nicolae
    Sticlaru, Carmen
    Oancea, Cristian
    [J]. WIENER KLINISCHE WOCHENSCHRIFT, 2013, 125 (5-6) : 144 - 149
  • [10] Flecher X, 2016, BIOMECHANICS BIOMATE, P319