Measuring the Integrity of Gas-Phase Conformers of Sodiated 25-Hydroxyvitamin D3 by Drift Tube, Traveling Wave, Trapped, and High-Field Asymmetric Ion Mobility

被引:16
作者
Oranzi, Nicholas R. [1 ]
Kemperman, Robin H. J. [1 ]
Wei, Michael S. [1 ]
Petkovska, Violeta I. [2 ]
Granato, Scott W. [2 ]
Rochon, Benjamin [2 ]
Kaszycki, Julia [3 ]
La Rotta, Aurelio [3 ]
Fouque, Kevin Jeanne Dit [4 ,5 ]
Fernandez-Lima, Francisco [4 ,5 ]
Yost, Richard A. [1 ]
机构
[1] Univ Florida, Dept Chem, Gainesville, FL 32611 USA
[2] Axalta Coating Syst, Philadelphia, PA USA
[3] Excellims Corp, Acton, MA USA
[4] Florida Int Univ, Dept Chem & Biochem, Miami, FL 33199 USA
[5] Florida Int Univ, Biomol Sci Inst, Miami, FL 33199 USA
关键词
VITAMIN-D STATUS; MASS-SPECTROMETRY; INTERNAL ENERGY; DISSOCIATION; MS; FRAGMENTATION; SEPARATION; INFANTS; PROTEIN; COHORT;
D O I
10.1021/acs.analchem.8b05723
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantitation of the serum concentration of 25-hydroxyvitamin D is a high-demand assay that suffers from long chromatography time to separate 25-hydroxyvitamin D from its inactive epimer; however, ion mobility spectrometry can distinguish the epimer pair in under 30 ms due to the presence of a unique extended or "open" gas-phase sodiated conformer, not shared with the epimer, reducing the need for chromatographic separation. Five ion mobility mass spectrometers utilizing commercially available IMS technologies, including drift tube, traveling wave, trapped, and high-field asymmetric ion mobility spectrometry, are evaluated for their ability to resolve the unique open conformer. Additionally, settings for each instrument are evaluated to understand their influence on ion heating, which can drive the open conformer into a compact or "closed" conformer shared with the epimer. The four low-field instruments successfully resolved the open conformer from the closed conformer at baseline or near-baseline resolution at typical operating parameters. High-field asymmetric ion mobility was unable to resolve a unique peak but detected two peaks for the epimer, in contrast to the low-field methods that detected one conformer. This study seeks to expand the instrument space by highlighting the potential of each platform for the separation of 25-hydroxyvitamin D epimers.
引用
收藏
页码:4092 / 4099
页数:8
相关论文
共 45 条
  • [1] Analysis of isomeric opioids in urine using LC-TIMS-TOF MS
    Adams, Kendra J.
    Ramirez, Cesar E.
    Smith, Natalie F.
    Celia Munoz-Munoz, Ana
    Andrade, Lawrence
    Fernandez-Lima, Francisco
    [J]. TALANTA, 2018, 183 : 177 - 183
  • [2] Gas phase fragmentation of protonated esters in air at ambient pressure through ion heating by electric field in differential mobility spectrometry
    An, X.
    Eiceman, G. A.
    Rodriguez, J. E.
    Stone, J. A.
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 303 (2-3) : 181 - 190
  • [3] Monitoring structural changes of proteins in an ion trap over ∼10-200 ms:: Unfolding transitions in cytochrome c ions
    Badman, ER
    Hoaglund-Hyzer, CS
    Clemmer, DE
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (24) : 6000 - 6007
  • [4] Analytical measurement and clinical relevance of vitamin D3 C3-epimer
    Bailey, Dana
    Veljkovic, Kika
    Yazdanpanah, Mehrdad
    Adeli, Khosrow
    [J]. CLINICAL BIOCHEMISTRY, 2013, 46 (03) : 190 - 196
  • [5] Vitamin D Metabolism, Mechanism of Action, and Clinical Applications
    Bikle, Daniel D.
    [J]. CHEMISTRY & BIOLOGY, 2014, 21 (03): : 319 - 329
  • [6] How Hot are Your Ions Really? A Threshold Collision-Induced Dissociation Study of Substituted Benzylpyridinium "Thermometer" Ions
    Carpenter, John E.
    McNary, Christopher P.
    Furin, April
    Sweeney, Andrew F.
    Armentrout, P. B.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2017, 28 (09) : 1876 - 1888
  • [7] Investigating Differences in Gas-Phase Conformations of 25-Hydroxyvitamin D3 Sodiated Epimers using Ion Mobility-Mass Spectrometry and Theoretical Modeling
    Chouinard, Christopher D.
    Cruzeiro, Vinicius Wilian D.
    Beekman, Christopher R.
    Roitberg, Adrian E.
    Yost, Richard A.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2017, 28 (08) : 1497 - 1505
  • [8] Variability in the analysis of 25-hydroxyvitamin D by liquid chromatography-tandem mass spectrometry: The devil is in the detail
    Couchman, Lewis
    Benton, Christopher M.
    Moniz, Cajetan F.
    [J]. CLINICA CHIMICA ACTA, 2012, 413 (15-16) : 1239 - 1243
  • [9] Adding a new separation dimension to MS and LC-MS: What is the utility of ion mobility spectrometry?
    D'Atri, Valentina
    Causon, Tim
    Hernandez-Alba, Oscar
    Mutabazi, Aline
    Veuthey, Jean-Luc
    Cianferani, Sarah
    Guillarme, Davy
    [J]. JOURNAL OF SEPARATION SCIENCE, 2018, 41 (01) : 20 - 67
  • [10] Progress of liquid chromatography-mass spectrometry in measurement of vitamin D metabolites and analogues
    El-Khoury, Joe M.
    Reineks, Edmunds Z.
    Wang, Sihe
    [J]. CLINICAL BIOCHEMISTRY, 2011, 44 (01) : 66 - 76