Effect of condensing unit layout at building re-entrant on split-type air-conditioner performance

被引:33
作者
Chow, TT
Lin, Z
Liu, JP
机构
[1] City Univ Hong Kong, Kowloon, Hong Kong, Peoples R China
[2] Xian Jiaotong Univ, Sch Energy & Power Engn, Xian, Peoples R China
关键词
air-conditioner performance; energy conservation; CFD application;
D O I
10.1016/S0378-7788(01)00111-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The use of split-type air-conditioners is popular in residential buildings of Hong Kong. In new apartment buildings, the building re-entrants are the most frequent choice of the project team for placing the outdoor condensing units. Nevertheless, the effect of heat dissipation from all condensing units at a re-entrant can be detrimental. Improper condenser layout incurs energy wastage, equipment derating and malfunction problems. Because of the continuing changes in outdoor air conditions, individual air-conditioner usage and loading, accurate prediction of the thermal impact at a re-entrant is virtually difficult. Based on computational fluid dynamics (CFD) analysis incorporating with an energy performance evaluation model, the effectiveness of various condenser layout schemes in building re-entrants under steady-state conditions was explored in this paper. It was found that there are limited hard-and-fast rules to give definite solutions. Provided that there is no physical access problem, an alignment of condensing units facing inward to induce a positive inflow of air into the re-entrant is a desirable solution. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 14 条
[1]  
*AEA, 1998, CFX 4 2 FLOW SOLV US
[2]  
[Anonymous], 1993, ASHRAE HDB FUND
[3]   Building ventilation: a pressure airflow model computer generation and elements of validation [J].
Boyer, H ;
Lauret, AP ;
Adelard, L ;
Mara, TA .
ENERGY AND BUILDINGS, 1999, 29 (03) :283-292
[4]  
*CENS STAT DEP, 1999, HKSAR HONG KONG EN S
[5]   Prediction of on-coil temperature of condensers installed at tall building re-entrant [J].
Chow, TT ;
Lin, Z .
APPLIED THERMAL ENGINEERING, 1999, 19 (02) :117-132
[6]   Effect of building re-entrant shape on performance of air-cooled condensing units [J].
Chow, TT ;
Lin, Z ;
Wang, QA .
ENERGY AND BUILDINGS, 2000, 32 (02) :143-152
[7]  
CHOW TT, 2000, ARCHITECTURAL SCI RE, V43, P133
[8]   Epithelial cells are a major cellular source of the chemokine eotaxin in the guinea pig lung [J].
Cook, EB ;
Stahl, JL ;
Lilly, CM ;
Haley, KJ ;
Sanchez, H ;
Luster, AD ;
Graziano, FM ;
Rothenberg, ME .
ALLERGY AND ASTHMA PROCEEDINGS, 1998, 19 (01) :15-22
[9]  
Ferziger J.H., 2019, Computational Methods for Fluid Dynamics
[10]  
KHURABUCHI T, 1998, P 6 INT C ROOMVENT 9, P1