Three-Dimensional Finite Element Analysis of Maxillary Sinus Floor Augmentation with Optimal Positioning of a Bone Graft Block

被引:5
|
作者
Schuller-Goetzburg, Peter [1 ]
Forte, Thomas [1 ,3 ]
Pomwenger, Werner [2 ]
Petutschnigg, Alexander [3 ]
Watzinger, Franz [4 ]
Entacher, Karl [2 ]
机构
[1] Paracelsus Med Univ, Biomech & Biomat Res, Prosthet, Strubergasse 21, A-5020 Salzburg, Austria
[2] Salzburg Univ Appl Sci, Dept Informat Technol & Syst Management, Urstein Sud 1, A-5412 Puch, Austria
[3] Salzburg Univ Appl Sci, Dept Forest Prod Technol & Wood Construct, Markt 136a, A-5431 Kuchl, Austria
[4] Landesklinikum St Polten Lilienfeld, Dept Maxillofacial Surg, Probst Fuhrer Str 4, A-3100 St Polten, Austria
来源
SYMMETRY-BASEL | 2018年 / 10卷 / 02期
基金
奥地利科学基金会;
关键词
sinus lift; bone grafting; finite element analysis; 3D modeling; dental implant; STRESS-DISTRIBUTION; FORCE MEASUREMENTS; POSTERIOR MAXILLA; CORTICAL BONE; IMPLANT; LAW; INTERFACE; REGION;
D O I
10.3390/sym10020033
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: the aim of the computational 3D-finite element study is to evaluate the influence of an augmented sinus lift with additional inserted bone grafting. The bone graft block stabilizes the implant in conjunction with conventional bone augmentation. Two finite element models were applied: the real geometry based bone models and the simplified geometry models. The bone graft block was placed in three different positions. The implants were loaded first with an axial force and then with forces simulating laterotrusion and protrusion. This study examines whether the calculated stress behavior is symmetrical for both models. Having established a symmetry between the primary axis, the laterotrusion and protrusion behavior reduces calculation efforts, by simplifying the model. Material and Methods: a simplified U-shaped 3D-finite element model of the molar region of the upper jaw and a more complex anatomical model of the left maxilla with less cortical bone were created. The bone graft block was placed in the maxillary sinus. Then the von Mises stress distribution was calculated and analyzed at three block positions: at contact with the sinus floor, in the middle of the implant helix and in the upper third of the implant. The two finite element models were then compared to simplify the modelling. Results: the position of the bone graft block significantly influences the magnitude of stress distribution. A bone graft block positioned in the upper third or middle of the implant reduces the quantity of stress compared to the reference model without a bone graft block. The low bone graft block position is clearly associated with lower stress distribution in compact bone. We registered no significant differences in stress in compact bone with regard to laterotrusion or protrusion. Conclusions: maximum values of von Mises stresses in compact bone can be reduced significantly by using a bone graft block. The reduction of stress is nearly the same for positions in the upper third and the middle of the implant. It is much more pronounced when the bone graft block is in the lower third of the implant near the sinus floor, which appeared to be the best position in the present study.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Biomechanical effect of crestal bone osteoplasty before implant placement: a three-dimensional finite element analysis
    Hudieb, M.
    Kasugai, S.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 40 (02) : 200 - 206
  • [42] Biomechanical Factors Associated with Mandibular Cantilevers: Analysis with Three-Dimensional Finite Element Models
    Gonda, Tomoya
    Yasuda, Daiisa
    Ikebe, Kazunori
    Maeda, Yoshinobu
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (06) : E275 - E282
  • [43] Clinical and Histological Outcomes of Maxillary Sinus Floor Augmentation With Synthetic Bone Substitutes for Dental Implant Treatment: A Meta-Analysis
    Toledano-Serrabona, Jorge
    Romeu-i-Fontanet, Aleida
    Gay-Escoda, Cosme
    Camps-Font, Octavi
    Sanchez-Garces, Ma Angeles
    JOURNAL OF ORAL IMPLANTOLOGY, 2022, 48 (02) : 158 - 166
  • [44] Three-Dimensional Finite Element Analysis of Steel Silo
    Chen, Changbing
    Liang, Xingpei
    Bi, Shouyi
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 4031 - +
  • [45] Maxillary sinus floor augmentation with Bio-Oss or Bio-Oss mixed with autogenous bone as graft: a systematic review
    Jensen, Thomas
    Schou, Soren
    Stavropoulos, Andreas
    Terheyden, Hendrik
    Holmstrup, Palle
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (03) : 263 - 273
  • [46] Three-dimensional finite element analysis of the human ACL
    Haghpanahi, M.
    Jalayer, F.
    PROCEEDINGS OF THE 1ST WSEAS INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND BIOMEDICAL INFORMATICS, 2008, : 134 - +
  • [47] Three-Dimensional Finite Element Analysis of Maxillary Protraction Using Diverse Modes of Rapid Palatal Expansion
    Balakrishnan, Rajkumar
    Sengottuvel, Nagalakshmi
    Altaf, Syed Khalid
    Bhandari, Pawan Kumar
    Kumaragurubaran, Preethi
    Antony, Marshal
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [48] Three-dimensional finite element analysis of the maxillary central incisor in two different situations of traumatic impact
    da Silva, B. R.
    Moreira Neto, J. J. S.
    da Silva, F. I., Jr.
    de Aguiar, A. S. W.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 (02) : 158 - 164
  • [49] A three-dimensional finite element analysis of the sports mouthguard
    Gialain, Ivan Onone
    Coto, Neide Pena
    Driemeier, Larissa
    Noritomi, Pedro Yoshito
    Brito e Dias, Reinaldo
    DENTAL TRAUMATOLOGY, 2016, 32 (05) : 409 - 415
  • [50] Comparison of slope stabilization methods by three-dimensional finite element analysis
    Usluogullari, Omer F.
    Temugan, Ahmet
    Duman, Esra S.
    NATURAL HAZARDS, 2016, 81 (02) : 1027 - 1050