High-throughput liquid chromatography tandem mass spectrometry assay as initial testing procedure for analysis of total urinary fraction
被引:19
作者:
Sobolevsky, Tim
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif Los Angeles, David Geffen Sch Med, Dept Pathol & Lab Med, Olymp Analyt Lab, Los Angeles, CA 90095 USAUniv Calif Los Angeles, David Geffen Sch Med, Dept Pathol & Lab Med, Olymp Analyt Lab, Los Angeles, CA 90095 USA
Sobolevsky, Tim
[1
]
Ahrens, Brian
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif Los Angeles, David Geffen Sch Med, Dept Pathol & Lab Med, Olymp Analyt Lab, Los Angeles, CA 90095 USAUniv Calif Los Angeles, David Geffen Sch Med, Dept Pathol & Lab Med, Olymp Analyt Lab, Los Angeles, CA 90095 USA
Ahrens, Brian
[1
]
机构:
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Pathol & Lab Med, Olymp Analyt Lab, Los Angeles, CA 90095 USA
In the recent years, a lot of effort was put into the development of multiclass initial testing procedures (ITP) to streamline analytical workflow in antidoping laboratories. Here, a high-throughput assay based on liquid chromatography-triple quadrupole mass spectrometry suitable for use as initial testing procedure covering multiple classes of compounds prohibited in sports is described. Employing a 96-well plate packed with 10 mg of weak cation exchange polymeric sorbent, up to 94 urine samples and their associated positive and negative controls can be processed in less than 3 h with minimal labor. The assay requires a 0.5-ml urine aliquot, which is subjected to enzymatic hydrolysis followed by solid phase extraction, evaporation, and reconstitution in a 96-well collection plate. With a 10-min run time, more than 100 analytes can be detected using electrospray ionization with polarity switching. The assay can be run nearly 24/7 with minimal downtime for instrument maintenance while detecting picogram amounts for the majority of analytes. Having analyzed approximately 28,000 samples, nearly 400 adverse analytical findings were found of which only one tenth were at or above 50% of the minimum required performance level established by the World Anti-Doping Agency. Compounds most often identified were stanozolol, GW1516, ostarine, LGD4033, and clomiphene, with median estimated concentrations in the range of 0.02-0.09 ng/ml (either as parent drug or a metabolite). Our data demonstrate the importance of using a highly sensitive ITP to ensure efficient antidoping testing.
机构:
Karolinska Inst, Dept Lab Med, Div Clin Pharmacol, Stockholm, SwedenKarolinska Inst, Dept Lab Med, Div Clin Pharmacol, Stockholm, Sweden
Beck, Olof
Ericsson, Magnus
论文数: 0引用数: 0
h-index: 0
机构:
Karolinska Inst, Dept Lab Med, Div Clin Pharmacol, Stockholm, Sweden
Karolinska Univ Hosp, Sect Doping Control Lab, Stockholm, SwedenKarolinska Inst, Dept Lab Med, Div Clin Pharmacol, Stockholm, Sweden
机构:
Sports Med Res & Testing Lab, Suite 150A,560 Arapeen Dr, Salt Lake City, UT 84108 USASports Med Res & Testing Lab, Suite 150A,560 Arapeen Dr, Salt Lake City, UT 84108 USA
Cox, Holly D.
Eichner, Daniel
论文数: 0引用数: 0
h-index: 0
机构:
Sports Med Res & Testing Lab, Suite 150A,560 Arapeen Dr, Salt Lake City, UT 84108 USASports Med Res & Testing Lab, Suite 150A,560 Arapeen Dr, Salt Lake City, UT 84108 USA
机构:
Karolinska Inst, Dept Lab Med, Div Clin Pharmacol, Stockholm, SwedenKarolinska Inst, Dept Lab Med, Div Clin Pharmacol, Stockholm, Sweden
Beck, Olof
Ericsson, Magnus
论文数: 0引用数: 0
h-index: 0
机构:
Karolinska Inst, Dept Lab Med, Div Clin Pharmacol, Stockholm, Sweden
Karolinska Univ Hosp, Sect Doping Control Lab, Stockholm, SwedenKarolinska Inst, Dept Lab Med, Div Clin Pharmacol, Stockholm, Sweden
机构:
Sports Med Res & Testing Lab, Suite 150A,560 Arapeen Dr, Salt Lake City, UT 84108 USASports Med Res & Testing Lab, Suite 150A,560 Arapeen Dr, Salt Lake City, UT 84108 USA
Cox, Holly D.
Eichner, Daniel
论文数: 0引用数: 0
h-index: 0
机构:
Sports Med Res & Testing Lab, Suite 150A,560 Arapeen Dr, Salt Lake City, UT 84108 USASports Med Res & Testing Lab, Suite 150A,560 Arapeen Dr, Salt Lake City, UT 84108 USA